A.c drive, air circuit breaker, a.c three phase motor, panel board(manufacturing), plc/hmi, mccb..Distributors, export
Electrical breaker, megnatic contactor, plc, inverter, vfd, motors, copper cables, electronics circuits.
* 1P, 2P, 3P, 4P * Rated Current In(A):1~125 * Rated Voltage Ue(V): 230/ 400 * Rated Frenquency(HZ): 50/60 * Rated Short Circuit Capacity Icn (A): 10000
TERASAKI TEMPOWER ACB TYPES: AT06, AT16, AT12, AT20, AT25, AT32, AT40. TERASAKI TEMPOWER ACB Type AGR-11B,21B,22B,31B Overcurrent Protective Device) Types: AR208S, AR212S, AR216S, AR220S, AR325S, AR332S, AR440S, AR440SB, AR212H AR216H, AR220H, AR316H, AR320H, AR325H, AR332H, AR420H, AR440H.
AIR Circuit Breaker Spares And Parts Str 38 S , Motor Spring Charges , Coil , Shunt Closing Trip Etc
Buchholz Relay Single Phase Buchholz Relay Three Phase Buchholz Relay Buchholz relay in a transformer is an oil container housing the connecting pipe from the main tank to the conservator tank. It has mainly two elements. The upper element consists of a float. The float is attached to a hinge in such a way that it can move up and down depending upon the oil level in the Buchholz relay Container.
LV power air circuit-breakers and switch-disconnectors Masterpact Merlin Gerin Masterpact circuit breakers are used to protect and control low-voltage distribution systems. They may be installed in main LV switchboards (incoming units, main and secondary outgoers). Masterpact is a complete range offering a large selection of performance levels: c ratings from 800 to 6300 A AC, from 1000 to 8000 A DC; c breaking capacity from 40 to 150 kA rms; c operational voltages 690 V AC, 1000 V DC.
VACCUM CIRCUIT BREAKER ALL TYPE OF ABB VACCUM CIRCUIT BREAKER VD4 12.12.25 , VD4 12.12.40, VD4 07.12.25.... MANY MORE 11 KV , 33KV . VD4Medium voltage vacuum circuit-breaker12 kV - 1250...4000 A - 63 kA36/40.5 kV - 630...3150 A - 16...40 kAMedium Voltage Products The VD4 are a synthesis of the renownedtechnology in designing and constructing vacuuminterrupters embedded in resin poles, and ofexcellency in design, engineering and productionof medium voltage circuit-breakers.Embedding the interrupter in resin makes thecircuit-breaker poles particularly sturdy andprotects the interrupter against shocks, accumula-tion of dust and humidity.The vacuum interrupter houses the contacts andmakes up the interrupting chamber.
BRAND:L&T LARSEN & TOUBRO AIR CIRCUIT BREAKER C -POWER ALL TYPE EDO AND MDO AVAILABLE.
C&S MCCB , Moulded Case Circuit Breakers - Winbreak2 RANGE : Rating: 16A~1600A , Poles: 3P & 4P. Moulded Case Circuit Breakers - Winbreak RANGE: Rating: 15A ~ 1200A , Poles: 2P, 3P & 4P Moulded Case Circuit Breakers - WiNbreak1 RANGE : Rating: 16A ~ 400A in 3P & 4P Rating: 16A ~ 200A in single pole
SCHNEIDER MCCB ALL TYPE AVAILABLE . COMPACT NSXM , Product Type: Molded Case, Circuit Breaker Pole Number: 3 Pole, 4 Pole Voltage Level: Medium-Voltage, High-Voltage, Low-Voltage Switch Control: Manual, Automatic Rated current: 1000A Brand: Schneider
BRAND: L&T MCCB DU/DY With Thermal - Magnetic Release DU MCCB Range 2 Pole / 3 Pole / 4 Pole MCCBs DU250C/DU250/DU400N MCCBs DTH With Thermal - Magnetic Release Conforms to IS/IEC 60947-2 l 25kA, 36kA, 50kA & 70kA breaking capacities l Adjustable short-circuit settings: 6 - 10 x In** l Manual, Rotary and Motorised versions available@ l 20A to 630A, 3P & 4P l Adjustable overload settings: 0.8 - 1.0 x In l Ics= 100% of Icu* l Wide range of accessories
BRAND :L&T MCCB DU/DY With Thermal - Magnetic Release DU MCCB Range [8536] 3 Pole / 4 Pole MCCBs , 2 Pole / 3 Pole / 4 Pole MCCBs , DU250C/DU250/DU400N MCCBs DTH With Thermal - Magnetic Release
BRAND : SCHNEIDER MCB 6A - 32A Single Pole Schneider Miniature Circuit Breaker. Product Specification No.of poles 1-4 Pole Rated current 6 to 63 A Voltage 240-415 V Breaking Capacity 10 kA Frequency 50 Hz Curve Type B and C tripping curves Brand Schneider
ABB MCB System pro M compact S200M miniature circuit breakers are current limiting. Theyhave two different tripping mechanisms, the delayed thermal tripping mechanism foroverload protection and the electromechanic tripping mechanism for short circuitprotection. They are available in different characteristics (B,C,D,K,Z), configurations(1P,1P+N,2P,3P,3P+N,4P), breaking capacities (up to 10 kA at 230/400 V AC) and ratedcurrents (up to 63A). All MCBs of the product range S200M comply with IEC/EN 60898-1 and IEC/EN 609 47-2, allowing the use for residential, commercial and industrialapplications. Bottom-fitting auxiliary contact can be mounted on S200M to save 50%
What is MCCB. MCCB stands for Molded Case Circuit Breaker. It is another type of electrical protection device which is used when load current exceeds the limit of a miniature circuit breaker. The MCCB provides protection against overload, short circuit faults and is also used for switching the circuits.
DZ47 AC MCB circuit breaker series is used in lighting distribution system or motor distribution system for protecting overload and short-circuit condition. The product is light in weightreliable and excellent in performance. It has high breaking capacity up to 6kA. Its case and items are adopted with high fire-resistant and shock proof plastics. Mainly used in AC 50/60Hz single-pole 230V or two three four-pole 400V circuit for overload and short circuit protection as well as for on-off switching electric equipment and lighting circuit. The product complies with EN/IEC60898. Rated current(In) 1A, 2A, 3A, 4A, 6A, 10A, 13A, 16A, 20A, 25A ,32A ,40A, 50A, 63A, 100A Optional Rate voltage(Un) 230VAC / 415VAC / 400VAC / 415VAC Optional Breaking capacity 6kA Rated frequency 50/60Hz Tripping charateristics BCD Number of poles 1P, 2P, 3P, 4P, 1P+N, 3P+N Optional Rated impulse withstand voltage(Uimp) 4kV Electrical endurance 10000cycles Mechanical endurance 10000cycles Terminal Pillar type
CBM-II Series circuit breaker manager (CBM) is an integrated control relay, designed for 3KV to 35KV indoor switchgear, used for replace multiple components in LV compartment, can reduce LV panel space occupation. On it's panel it provide primary circuit simulation diagram, switch indicator, VCB status & control switch, environment control, high voltage indicator etc. Special sound prompt function can remind staff to operate the switchgear safely. It can be used in various types of switchgear such as GZS (Centrally Installed Switchgear), Handcart Cabinet, Fixed Cabinets, Ring Main Unit, etc.
MCB distribution box SPN- single door, double door. MCB distribution box TPN- single door, double door.