C&S MCCB , Moulded Case Circuit Breakers - Winbreak2
RANGE : Rating: 16A~1600A , Poles: 3P & 4P.
Moulded Case Circuit Breakers - Winbreak
RANGE: Rating: 15A ~ 1200A , Poles: 2P, 3P & 4P
Moulded Case Circuit Breakers - WiNbreak1
RANGE : Rating: 16A ~ 400A in 3P & 4P
Rating: 16A ~ 200A in single pole
ALSTOM GBCDG61EG040SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Relay Technical specification Relay model no CDG61EG040SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Aux.Contacts With Flag 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 1.3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set conts.With flag CAG 13 / 2M S/R Name plate RFG9125 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG018SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG018SGCH Relay type CDG 61 Case size 3D H 30T Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3 N/O S/R Output contacts 2 N/O S/R C.T.Secondary 1 amps Frequency 50 Hz Tap Std Burden / D.M.T 3 VA / 3 Secs Current setting - E/F 0.2 to 0.8 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 2 to 8 amps High set/High set contact CAG 13 / 2 N/O S/R Name plate RFG9126 902 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG020SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG020SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 0.5 to 2 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 1 amps Frequency 50 Hz Burden 3 VA Operating time 3 secs Current setting - E/F 0.1 to 0.4 amps High set - O/C Setting 4 to 16 amps High set - E/F Setting 1 to 4 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9126 901 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
ALSTOM GBCDG61EG041SGCH IDMT TWO O/C & ONE E/F RELAY WITH HIGH-S Technical specification Relay model no CDG61EG041SGCH Relay type CDG 61 Case size 3D H 30T Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Contacts / Output contacts 3M S/R / 2M S/R C.T.Secondary 5 amps Frequency 50 Hz Burden 3 VA Operating time 3 secs Current setting - E/F 0.5 to 2 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 5 to 20 amps High set CAG 13 Name plate RFG9126 903 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
Cable Trays, C Channel, Threading Rod, Nut Bolt Washer, GI Flexible, GI Saddle, GI Strips, Cable Clip, Cable Lugs, Cable Clamps, Cable Ties, Sockets and PVC Ferrules, Flexible Wires, Cables, MCB, RCCB, Switchgears, Fuses, Distribution Boards, Plug and Socket, Chemical, Salt, Silica Gel, Fire Bucket, First Aid Kit, Telephone Cables, Telephone Pair Boxes, Meters Analog and Digital, Panel Accessories and Industrial Fittings, PVC Channels, Rubber Mats, Cable Jointing Kits, Fastener, Cast Iron Chamber Cover, Conduit Pipe, Copper Strip, Cotton Tape, cylinder Fire Items, Drill Chuck, Drilling Bits, Earthing Wires, Flexible GI and Stand, Flexible Conduit Hose Pipe, GI Earth Electrode, GI Strip, Hammer Chisel Summa, Hand Tools and Accessories, M S Cutter Blades, Marble Cutter Wheel and Hole Saw, MS Accessories, MS Channel, MS Hooks, MS Pipe, Plier, Neutral link Items, Paper Base Electrical Laminates Sheet, Round Sheets, Power Strip and MCB Box, PVC Pipe and accessories, PVC Stopper, PVC Tape, Rubber Hand Gloves, Rubber Mats, Rubber Sheets Items, Safety Goggles, Safety Helmets, Safety Jackets, Safety Shoes and other safety items, Aluminum Ladder, Aluminum Tape, Aluminum Stripes, Bucket Fire Items, Bulb Light, Bulked and Hand Lamp, Instruction Charts.
GBCDG31EG002SACH NON DIR.SELF POWER 3 O/C RELAY 2M S/R TECHNICAL SPECIFICATION Model No : CDG31EG002SACH CDG31 APPLICATION - 3 O/C BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D HORZ. CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C OR O/V SETTING - 0.5 - 2 Amps. Name Plate RFG9126771 Outline Diagram MFJ014 Wiring Diagram MADZ802-63-1
ALSTOM GBCDG31FF002SACH NON DIR.SELF POWER 3 O/C RELAY 2M S/R Model No : CDG31FF002SA(M) CDG31 APPLICATION - 3 O/C BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 1 AMP CT. CASE SIZE - 3D VERT. CONTACTS (S/R OR H/R) - 2 N/O S/R FLAG - YES FREQUENCY - 50 HZ MOUNTING - FLUSH O/C SETTING - 0.5 - 2 Amps. Name Plate RFG9126671 Outline Diagram MFJ013 Wiring Diagram MFDZ801-101-1
GBCDG61EG011SGCH IDMT 3 O/C OR 2O/C& 1 E/F RELAY WITH HI Technical specification Relay model no CDG61EG011SGCH Relay type CDG 61 Case size 3D HOR. Application 2 O/C & 1 E/F Current setting - O/C 2.5 to 10 amps Contacts 3M S/R Output contacts 2M S/R C.T.Secondary 5 amps Taps / Frequency STD / 50 Hz Burden 3 VA Operating time 3 secs Flag Yes Current setting - E/F 1 to 4 amps High set - O/C Setting 20 to 80 amps High set - E/F Setting 10 to 40 amps High set/High set contact CAG 13 / 2M S/R Name plate RFG9126 904 Outline drawing MFJ 014 Wiring diagram MADZ 821.27-1
Gbcdg61eg101zmch Idmt 3 O/c or 2o/c& 1 E/f Relay With Hi Model No : Cdg61eg101zm(M) Cdg61/cag17(Mrk-iii) Application - 3 O/c Burden / D.m.t - 3 Va / 3 Sec. C.t. Secondary - 5 Amp C.t. Case Size - 3d Horz. Contacts (S/r or H/r) - 2 N/o S/r Flag - Yes Frequency - 50 Hz High Set Type - Cag17 Highset Contacts - 2m S/r Highset O/c Setting - 12.5 - 100 Amps. Mounting - Flush O/c Setting - 2.5 - 10 Amps. Name Plate - Rfg9126 774 Outline Diagram - Mfj 014 Wiring Diagram - Madz821.31