NAP-66A is mainly used for gas detectors and leak testers. NAP-66A is a half in height and needs a half in power consumption compared to existing sensor so that thinner and lighter-weight detectors can be produced. The following are the basic characteristics but it is recommended to refer to the individual users manual for further information.
* Target gases and concentration
Propan(C3H8): 0.03~ 2.2% (0.03~ 1%)
Iso-butane(Iso-C4H10): 0.03~ 1.8% (0.03~ 0.8%)
Hydrogen(H2):0.05~ 4% (0.05~ 1.5%)
Ethanol(C2H5OH): 0.05~ 3.2% (0.05~ 1.5%)
Hydrocarbons(CnH2n+2): 1~100% LEL (1~50%LEL)
( ) is a detection range in high accuracy
* Ratings
Supply Voltage:
DC 2.0 ± 0.2V
AC 2.0 ± 0.2V (r.m.s. 50~60Hz)
Current (When 2.0V is applied):
DC 140 ~ 160mA
AC 140 ~ 160mA (r.m.s. 50~60Hz)
Ambient Temperature:
In operation -10 ~ +50
In storage -10 ~ +50
Ambient humidity:
In operation 95ï¼?RH or less
In storage 99ï¼?RH or less (No dew condensation)
Supplier: Gas lighter, led screen protector ( not even in domestic ), refill paper cups, table runner, earing brass clamp, auto brass electric parts, cashew nuts, wire mesh, petha sweet, niwar, mohini powder, vermicompost, dry bath incubator, test tube plastic, sordium citrate tube, health care product, ornamental freshwater fish, safed musli, used polymer bag, cotton linter, auto hood cover, areca plate, rice
Our most advanced intelligent spot detectors, multi-criteria/multi-sensor devices use multiple sensors to detect various conditions in an environment sensing a wider range of fires with greater accuracy. Features & Benefits: Multi-Criteria/Multi-Sensor smoke detection Unique ability to detect major elements of a fire Highest nuisance alarm immunity Advanced algorithms interpret and respond to multiple inputs
Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
Description: Nap-56a is not made with thermoplastics to achieve a higher temperature Resistivity. The pin locations and dimensions are compatible to nap-55a for the Convenience of current users of nemoto nap-55a. The gas sensitivity is better Than nap-55a by about 15%. Users are to pay attention to this higher gas Sensitivity upon calibration. Target gases and concentration Gasesdetection range Methanech40.05 - 5% (0.05 - 2%) Ethanec2h60.05 - 3.2%(0.05 - 1.5%) Hydrogenh20.05 - 4% (0.05 - 1.5%) Hydrocarbonscnh2n+21 - 100%lel (1 - 50%lel) ( )is a detection range in high accuracy Gas sensitivity characteristics Gas & concentrationoutput voltage Output in clean air-35 - +35 mv Methane 3, 000 ppm15 - 23 mv Iso-butane 1, 400 ppm12 - 18 mv Hydrogen 1, 400 ppm10 - 17 mv Ratings Itemsratings Supply voltagedc 2.5±0.25v Ac 2.5±0.25v(r.M.S. 50-60hz) Current (2.5v supplied)dc 150 - 170ma Ac 150 - 170ma(r.M.S. 50-60hz) Ambient temperaturein operation -10 - +50°c In storage -10 - +50°c Ambient humidityin operation 95%rh or less In storage 99%rh or less(no dew condensation)
Nap-50a is a miniature & low power consumption type sensor. Nap-50a is Mainly used for gas detectors. Compared to nap-55a, nap-50a has a lower Alcohol sensitivity to eliminate false alarms caused by alcohol, thus more reliable Gas detectors can be produced with nap-50a. The following are the basic Characteristics but it is recommended to refer to the individual user’s manual for Further information. See nap-66a for measuring circuit for sensor evaluation. Target gases and concentration GasesDetection range MethaneCh40.05 - 5% (0.05 - 2%) EthaneC2h60.05 - 3.2% (0.05 - 1.5%) HydrogenH20.05 - 4% (0.05 - 1.5%) HydrocarbonsCnh2n+21 - 100%lel (1 - 50%lel) ( )is a detection range in high accuracy Gas sensitivity characteristics Gas & concentrationOutput voltage Output in clean air-35 - +35 mv Methane 3, 000 ppm10 - 16 mv Hydrogen 1, 400 ppm7 - 12 mv Ethanol 1 %Less than 10 mv Ratings ItemsRatings Supply voltageDc 2.5±0.25v Ac 2.5±0.25v(r.M.S. 50-60hz) Current (2.5v supplied)Dc 150 - 170ma Ac 150 - 170ma(r.M.S. 50-60hz) Ambient temperatureIn operation -10 - +50°c In storage -10 - +50°c Ambient humidityIn operation 95%rh or less In storage 99%rh or less(no dew condensation)
Description E1000 is a portable rechargeable single gas detector. It can detect the concentration of combustible gases, oxygen and toxic gases in the surrounding environment, and send out information when an abnormality occurs. Itâ??s easy for replacement and maintenance by the user himself with adopting smart sensor module. It is applicable to explosion-proof places: steelworks, petrochemical plant, oil industry, shipbuilding yard, sewage treatment plant, mine, power supply works etc. Key Features Real-time clock Smart interchangeable sensor module Calibration point adjustable Two alarm level STEL alarm and TWA alarm for toxic gases Visual, audible, vibrating alarm Self protection against high concentration combustible gas Low battery alert Data uploading Password management Self-test when power on Self-diagnostic and self-correction function GPS, GPRS and Man-down function optional
Items Technical parameter Detection Range a1000ppm Max detecting bound 2000ppm Detecting life 5 years Sensitivity 0.015 Resolution 0.5ppm Temperature range Pressure range Normal atmosphere Response time(T90)
Supplier: Gas analyzer, natural gas analyzer, best natural gas detector
The NFS-3030 is a fire alarm control panel (FACP) manufactured by Notifier. It is designed for use in small to medium-sized fire protection systems and provides effective fire detection and alarm notification. The NFS-3030 features a compact design and advanced microprocessor technology, making it easy to install and program. The control panel supports up to 384 points and includes built-in communication options, such as analog dialer and network interfaces, for remote access and system integration. It is compatible with a range of Notifier fire detectors, modules, and accessories, providing versatility and customization for specific fire protection needs. The NFS-3030 is a cost-effective and reliable fire alarm control panel from Notifier.