Description:
Nap-56a is not made with thermoplastics to achieve a higher temperature
Resistivity. The pin locations and dimensions are compatible to nap-55a for the
Convenience of current users of nemoto nap-55a. The gas sensitivity is better
Than nap-55a by about 15%. Users are to pay attention to this higher gas
Sensitivity upon calibration.
Target gases and concentration
Gasesdetection range
Methanech40.05 - 5% (0.05 - 2%)
Ethanec2h60.05 - 3.2%(0.05 - 1.5%)
Hydrogenh20.05 - 4% (0.05 - 1.5%)
Hydrocarbonscnh2n+21 - 100%lel (1 - 50%lel)
( )is a detection range in high accuracy
Gas sensitivity characteristics
Gas & concentrationoutput voltage
Output in clean air-35 - +35 mv
Methane 3, 000 ppm15 - 23 mv
Iso-butane 1, 400 ppm12 - 18 mv
Hydrogen 1, 400 ppm10 - 17 mv
Ratings
Itemsratings
Supply voltagedc 2.5±0.25v
Ac 2.5±0.25v(r.M.S. 50-60hz)
Current (2.5v supplied)dc 150 - 170ma
Ac 150 - 170ma(r.M.S. 50-60hz)
Ambient temperaturein operation -10 - +50°c
In storage -10 - +50°c
Ambient humidityin operation 95%rh or less
In storage 99%rh or less(no dew condensation)
Supplier: Gas lighter, led screen protector ( not even in domestic ), refill paper cups, table runner, earing brass clamp, auto brass electric parts, cashew nuts, wire mesh, petha sweet, niwar, mohini powder, vermicompost, dry bath incubator, test tube plastic, sordium citrate tube, health care product, ornamental freshwater fish, safed musli, used polymer bag, cotton linter, auto hood cover, areca plate, rice
Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
Our most advanced intelligent spot detectors, multi-criteria/multi-sensor devices use multiple sensors to detect various conditions in an environment sensing a wider range of fires with greater accuracy. Features & Benefits: Multi-Criteria/Multi-Sensor smoke detection Unique ability to detect major elements of a fire Highest nuisance alarm immunity Advanced algorithms interpret and respond to multiple inputs
NAP-66A is mainly used for gas detectors and leak testers. NAP-66A is a half in height and needs a half in power consumption compared to existing sensor so that thinner and lighter-weight detectors can be produced. The following are the basic characteristics but it is recommended to refer to the individual users manual for further information. * Target gases and concentration Propan(C3H8): 0.03~ 2.2% (0.03~ 1%) Iso-butane(Iso-C4H10): 0.03~ 1.8% (0.03~ 0.8%) Hydrogen(H2):0.05~ 4% (0.05~ 1.5%) Ethanol(C2H5OH): 0.05~ 3.2% (0.05~ 1.5%) Hydrocarbons(CnH2n+2): 1~100% LEL (1~50%LEL) ( ) is a detection range in high accuracy * Ratings Supply Voltage: DC 2.0 ± 0.2V AC 2.0 ± 0.2V (r.m.s. 50~60Hz) Current (When 2.0V is applied): DC 140 ~ 160mA AC 140 ~ 160mA (r.m.s. 50~60Hz) Ambient Temperature: In operation -10 ~ +50 In storage -10 ~ +50 Ambient humidity: In operation 95ï¼?RH or less In storage 99ï¼?RH or less (No dew condensation)
Gas leak detection in stationary fuel cells combustible gas sensor module Model number:cgm6812--b00 Features: * linear analog output proportional to gas Concentration * maintenance free * compact size * meets rohs requirements Applications: * gas leak detection in fuel cell systems * hydrogen & combustible gas leak Detectors Description: The cgm6812-b00 combustible gas sensor module is A new unit which utilizes tgs6812, figaro's catalytic Pellistor type gas sensor which features durability and stability. This module provides analog output voltage proportional to hydrogen gas concentration. Cgm6812-b00 has conformal coatings for moisture- Proofing and electrical insulation purposes, and is also Capable of detecting sensor wire breakage. The unit has A wide range of operating temperature from -10' to +60'c. Because the tgs6812 sensor can detect methane and lp gas As well as hydrogen, this module is suitable for gas Leak detection in stationary fuel cells which use hydrogen Generated from combustible gases Sensor Module Cgm6812
The NFS-3030 is a fire alarm control panel (FACP) manufactured by Notifier. It is designed for use in small to medium-sized fire protection systems and provides effective fire detection and alarm notification. The NFS-3030 features a compact design and advanced microprocessor technology, making it easy to install and program. The control panel supports up to 384 points and includes built-in communication options, such as analog dialer and network interfaces, for remote access and system integration. It is compatible with a range of Notifier fire detectors, modules, and accessories, providing versatility and customization for specific fire protection needs. The NFS-3030 is a cost-effective and reliable fire alarm control panel from Notifier.
The NFS2-640 is a fire alarm control panel (FACP) manufactured by Notifier. It is designed for use in medium to large-scale fire protection systems and provides reliable fire detection and alarm notification. The NFS2-640 features a compact design and advanced microprocessor technology, allowing for easy installation and programming. The control panel supports up to 640 points and includes built-in networking capabilities for remote access and system integration. It is compatible with a range of Notifier fire detectors, modules, and accessories, offering flexibility and customization for specific fire protection needs. The NFS2-640 is a feature-rich and reliable fire alarm control panel from Notifier.
FSM-10H-01 Pre-calibrated Module for LPG Gas FSM-10H-01 is Pre-calibrated Module for LPG gas alarm which applies TGS2610-D00 sensor together, it features durability and stability. The module outputs PWM signal which is proportional to LPG gas concentration (The module has a memory which is stored with factory calibration data), also is capable of detecting sensor wire breakage and short. The module can operate at wide temperature from -10~70'C. Furthermore, the unit is less sensitivity to VOCs gas, it immunes poison by silicon compounds, it suits to work at rugged environment. FSM-10H-01 Combustible Gas Sensor Module Features * PWM, USART digital output proportional to gas concentration * Maintain Free * Compact size, low cost * Meets RoHS requirement FSM-10H-01 Combustible Gas Sensor Module Applications * Detect flammable gas leakage * Flammable gas leakage Detector * Industrial detector FSM-10H-01 Combustible Gas Sensor Module Specification * Gas sensor: TGS2610-D00(Semiconductor) * Detection range: 0 ~ 4,000ppm H2 * Error: ± 300ppm * Response time (T90): �30S * Operation temperature: -10'C ~+70'C * Operation humidity: 20~95%RH(No condensing) * Input voltage (VIN): 5.00.2V DC * Power consumption: 15W
Fsm-t-04a combustible gas sensor module description The fsm-t-04a combustible gas sensor module is a new unit which utilizes tgs6812, catalytic pellistor type gas sensor which features durability and stability. This module provides analog output voltage proportional to hydrogen gas concentration.(there is a memory in module, where factory calibration data has been store). Fsm-t-04a has conformal coatings for moisture proofing and electrical insulation purposes, and is also capable of detecting sensor wire breakage. The unit has a wide range of operating temperature from -10 to +70'c. Furthermore, the unit can detect ch4, lpg, h2. It is less sensitivity to vocs gas, it immunes poison by silicon compounds, it suits to work at rugged environment. Fsm-t-04a combustible gas sensor module features: * linear analog output proportional to gas concentration * maintenance free * compact size * meets rohs requirements Fsm-t-04a combustible gas sensor module applications: * gas leak detection in fuel cell systems * hydrogen & combustible gas leak detectors Fsm-t-04a combustible gas sensor module specification * gas sensor: tgs6812 (catalyâ??tic type) * detection range: 0 ~ 50, 000ppm ch4 * error: 3%lel * response time (t90): 30s * operating temperature: -10'c ~ +70'c * operating humidity: 20~95%rh (no condensing) * input voltage: 5.00.2v dc, 3.00.1v dc * power consumption: 1.5w