1. General HS-SG109 Sound Strobe of notification appliances offers a wide range of Sound/strobes, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC systems.
1. General Conventional Fire Alarm Control Panel with four Zones 2. Specifications Two Style B (Class B) Initiating Device Circuits (IDCs). All zones accept two-wire smoke detectors and any normally-open contact devices. One built-in Fire Fighting Ouput. 24-volt operation. Resettable four-wire smoke detector power 500 mA. Non-resettable power 500 mA. One-man walk-test programmable for silent or audible test. Disable/Enable control per IDC. Reverse polarity protection. 3. Packaging and shipping Conventional Fire Alarm Control Panel with four Zones 1 pc/carton box;carton M:43*17*51cm
Model No. SR-812PC-2 Operating voltage DC9~35V Alarm temperature N/A Static current 20uA Alarm current 35mA@DC12V;83m@DC24V Alarm output Remote LED indicator Installation Ceiling mounted Sensitivity 2.06%ft±1.3%ft Working environment -10~+50(â?¤95%RH No congelation) Dimension 100*46mm
1. General HS-JL188-6 Electric bell of notification appliances offers a wide range of Sound, for wall and ceiling applications, indoors and outdoors. They are designed to be used in 24 volt DC systems. 2. Specifications Name 6" Alarm Bell Item No. HS-JL188-6 Operating voltage DC24V Alarm current 70mA @ DC24V Alarm sound intensity Minimum 95dB Dimension Diameter 155mm, height 45mm Weight 650g Features Easy to install bracket 3. Features Operating Voltage : DC24V Alarm Current: Maximum 70 mA Alarm Sound Intensity: Minimum 95dB
Conventional fire fighting control panel with 4 zones and 3 sound output, designed to connect with 2/4 wired smoke detector, heat detector, manual call point, manual release, gas release lamp etc. 1. Specifications a. Four Style B (Class B) Initiating Device Circuits (IDCs). b. All zones accept two-wire smoke detectors and any normally-open contact devices. c. One built-in Fire Fighting Ouput. d. 24-volt operation. e. Resettable four-wire smoke detector power @ 500 mA. f. Non-resettable power @ 500 mA. g. One-man walk-test programmable for silent or audible test. h. Disable/Enable control per IDC. i. Reverse polarity protection.
The device is an Ultraviolet-only flame detector designed to detect fires and provide alarm outputs directly from the detector while maintaining false alarm immunity. It detects in the ultraviolet (UV) spectral range for optimized speed of response. It is fast and capable to detecting the ultraviolet (UV) rays emitted by a burning substance and is used in high hazard applications such as petrochemical plants, munitions factories and other areas where flammable or explosive liquids or solids are handled or stored. The flame sensor adopts an ultraviolet photosensitive tube, with qualities of highly sensitive, reliable, dust-resistant, corrosion proof and moisture-resistant, therefore is not sensitive in sunlight, dust, oil, tolerance of fume, and humidity. Set in a standard calibration to detect a flames at a distance of 25 meters, which flame created by 2Kg ethanol in a Container of Base 33cmX33cm, Height 5cm.
Smoke, heat, gas, co detectors alarm, conventional, addressable fire alarm control panel, sounder.
The 640 addressable audio/visual alarm devices are suitable for connection to 2-wire addressable fire detection And alarm systems. 640 is loop-powered and activation is initiated by a dedicated initiation message from the control and indicating Equipment. Up to 125 devices can be connected to each alarm zone loop. Visual, audible and audio/visual models available Red or white body available for audible alarm device Loop-powered from control and indicating equipment Operates when a dedicated activation message is received from the control and indicating equipment Loud sounder output of 85 db at 1 m Long-life leds Low quiescent current Dip switch address setting
Grains like corn, corn gluten meal, ddgs, soybeans, soybean meal, soy hull pellets, canola meal and pellets, cotton seeds and meal, and wheat, conventional or organic (non gmo), dairy products, frozen meats and seafood, plastic scraps, fish meal, fish oil, whey powder, flax seeds, beet pulp pellets, meat and bone meal, poultry meal, feed, 3d printers, beans, peas, nuts.Commodities brokerage firm
AC POWER: 220VAC, 50 Hz. BATTERY: Sealed lead-acid batteries only. Maximum charging circuit: 27.6VDC @ 0.8 amp for normal flat charge. Maximum battery charger capacity: 18AH battery. NOTE: Two 10AH batteries can be housed in the cabinet. Larger batteries require a separate battery box. Total DC24V system power: 3.0 amps. Maximum current per NAC: 1.25 amps. Maximum battery charging capability: 18 AH. Resettable four-wire smoke detector power output. Non-resettable power output. Integral Form-A Alarm, Trouble and Supervisory relays, rated at: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive).
Conventional fire alarm smoke detector smoke probe sensor This device is photoeletronic detector uses a state-of-the-art optical sensing chamber. This smoke detector is compatible with all conventional fire alarm control panel Dual leds, two leds blink standby, provide 360dgree visibility With unique optical sensing chamber, engineered to sense smoke by a wide range of combustion sources. Unpolarized wire input to prevent the likelihood of wiring errors Specifications Operating voltage range: 9 to 28vdc volts non-polarized Standby current: 60µa @ 24 vdc Maximum alarm current (led on: ) 30ma @ 24 vdc Operating humidity range: 10% to 93% relative humidity, non-condensing Operating temperature range: 14°f to 122°f (-10°c to50°c) Adjustable sensitivity: 0.15ï½?0.3db/m Height: 2.2ë� (55 mm) installed in base Diameter: 4.0ë� (103 mm) Weight: 5.5 oz. (155 g)
Power Supply: AC 240V 50/60Hz Stand-by Battery: DC24V Sealed Maintenance-Free Lead-Acid Battery Charging Voltage: DC26.4V Below 450mA Trickle Charging Circuit Voltage: DC24V Short Circuit Voltage 5V below 32mA Loop Resistance: Below 50+ back and forth Detector Installation: No limit in the number of differential detector & constant-temperature detectors used; smoke detectors or electronic differential detectors; each ciruit can connect to a maximum of 16 smoke detectors (monitoring current for detectors: DC24V 40¦A) Terminal Resistor: 10k+ Number of indicators: 1 time the number of panel circuits Number of Local Alarm: 1 time the number of panel circuits. Number of circuit & Dimension: 1L/2L/4L/5L/8L (330x280x120mm) 12L/16L(400x300x120mm) 24L(495x300x120mm).
Backlight Digital LCD Alarm Clock Smart back-light: smart light(auto light at night) Auto on when into dark,when you put the clock into dark, it will light up by itself. Dim brightness of backlight, with on/off of sensor for smart light Light up when press the button, normal brightness different from smart light. 5 minutes repeating ascending snooze alarm,with on/off setting of snooze. Big digits time display, big LCD size digits display screen: Alarm time display,12/24 hour time format, calendar display Battery Digital Clock: digital clock battery operated, No USB cable. Need 3* AAA 1.5V batteries (NOT INCLUDED) Big LCD screen, energy saving, clear boldface number display, easy to read. Convertible , 12HR & 24HR with simple operation. Mini small digital clock, whole size of a palm , it can be stashed in bag when travel. Kids alarm clocks for girls: 4 Color choose. pink clock for girls; blue/ black/white alarm clock for kids teens When alarm is activated, the clock sounds beep for 60 seconds in a crescendo Smart Alarm light,built in light sensor,LCD backlight turns on automaticaly when the room or circumstance becomes dark.and don't worry,this also wont disturb the sleepness.
2 wire 9V-28VDC powered conbined Smoke detector and Heat Detector electronic conbined fire alarm HS-FT103 1pc/blister box(103*103*55mm,155g) ;60pcs/carton box They work perfectly with all conventional intelligent fire control panels Advanced MCU Expert Algorithm Software. Easy installation and maintenance Durable sensor head, no need for replacement
1. Current overload or line surge shutdown 2. High temperature compressor shutdown. 3. High pressure alarm shutdown. 4. Low pressure alarm shutdown. 5. Low oxygen cocentrator alarm. Oxygen concentrator: 0.5-5L/min Purity: 95%+_3% Working system Continuous Power Supply AC230V.50Hz/AC220V.60HZ AC120V.60Hz Power: 390VA Net Weight: 16kg( Gross weight: 18.5kgs) Warranty: Long-life compressor designed for 1000 hours of maintenance-free use. Size: 33*26*54cm
Specifications 1.odorless 2.low VOC 3.antimicrobial 4. mildew resistant 5.environmentally friendly 6.waterproof 7.Scrub resistance Description It is an enhanced mildew proof product adopting nano-scale Ag+ antimicrobial and mildew proof technology, integrating odorless formula, with fresh product smell, smooth paint film, durable and beautiful paint.As an affordable and environmentally friendly product with excellent decorative performance, it is characterized by fresh smell, environmental health, strong covering power, large painting area, convenient constructionapplication, short constructionapplication period, etc. Specification Data Solvent: Water Pigment: Non-lead pigment Theoretical Solids By Volume: more than 50% Theoretical Coverage: Theoretically 1 litre of this product covers 12 sqm in 1 coat Coverage varies considerably depending on application methods and surface roughness and porosity. Shelf Life: Minimum 12 months at 77F(25C) unopened and store in cool and dry places. Recommended Film Thickness: Wet: 80 micron Dry: 30 micron Dry Time: At 77F (25C) and 50% R.H. to recoat Touch Dry: 1 hours Recoat : 2-3 hours Application: Brush, Roll, conventional spray or Airless Spray. Thinner: Thin up 15% depend on different application methods & temperature. Do not over thin by adding more than 30% water. Brush or Roller: For sealing new or bare surfaces thin with up to 1 part of clean water to 5-10 parts of paint(10%-20%) Conventional Spray: Add up to 1 part clean water to 5 parts paint(20%) Airless spray: do not thin Clean-up: Clean up equipment with water Typical painting system Substrate System All kinds of Wall surfaces 1.Alkali Resistance Primer (1 coat) 2.Emulsion Wall Paint (2 coats)
We supply 25mm, 26mm Plain Particle Boards for filling inside the doors. 2440x1220x26mm plain particle board shall weigh about 40kgs. We do particle board starting 9mm to 40mm and above for various purposes like lamination grade fully sanded on both faces, for routing purpose, furniture backing etc. 26mm(non sanded) :520Kg/m3 - E2 Grade 30 to 64mm- E1, High Moisture Resistance, Both Sides sanded 26mm(non sanded) :520Kg/m3 - E2 Grade 30 to 64mm- E1, High Moisture Resistance, Both Sides sanded, suitable for Fire door -tested to BS standard We can also adjust the density of board as per our customer requirement. Our plain particle boards are priced competitive. Please contact us for more details.