Scope
Standard ASTM D93, GB / T261-83 and ISO2719-1988 international standards.

Features
1, large-screen LCD, friendly user interface
2, also has a fault of Jane function, automatic fault prompts
3, automatic temperature control, automatic lid opening and ignition, automatic print, automatic cooling, automatic air pressure correction is completed and the machine automatically displays the flash point temperature, built-in mini thermal printer to automatically report the test results
4, using USB / 232 communication interface to communicate with the host machine, a centralized management system for easy composition
5, from Germany imported stainless steel temperature sensor for detecting the temperature data is accurate and reliable
6, mechanical moving part of the servo-driven belt drive, work without gaps, low noise, reliable easy to damage, no lubrication maintenance.
7, just set the expected flash point, the instrument automatically in strict accordance with the standard test, the test ends automatically print test results, and there is a tone. Without judgment and do not rely on the operator's proficiency.
8, thermocouple detection sensitivity high detection accuracy, durability and easy maintenance.
9, sample box with built-in cooling mode heating thermostat thermal compound, and the use of German imports whisk Dan Adams compressors, thermostats no lag reliable, easy to damage

Technical Parameters
1. Environment: Temperature 0 ~ 60 ? Relative humidity: = 80%
2, Display: large-screen LCD
3, heating rate: less than 50 ? 1 ? / min, higher than 50 ? 2-3 ? / min
4, temperature range: -30 ~ + 80 ?, accuracy ± 1 ?
5, the temperature measurement element: PT100 stainless steel temperature sensor
6, the ignition: gas flame ignition
7, Detection: Automatically detects a flash fire and automatically print test data.
8. Communication: USB / 232 communication interface.
9, cooling system: compressor cooling
10, print: You can print the results of this experiment or any print storage
11, using the power AC220V 50Hz, the total power: 1.5 kw

Price and Minimum Quantity

Price: $100
MOQ: Not Specified

Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Automatic Flash Point Tester

Jul-30-15
 
Scope of application
For flash and Fire points of all petroleum products, except fuel oils and those having an open cup flash below 79 C (175F).
Benefits
- Conforms to ASTM D92 and related specifications
- For flash points above 79 C (175F)
Function characteristics
1,english operating software prompts;
2, with the experimental date, test time parameter prompts;
3, automatic correction of atmospheric pressure and calculated correction values;
4 differential detection, automatic correction system deviation;
5, scan, ignition, detection, print test data computer is done automatically;
6, electronic ignition, the gas flame, forced air cooling detection of anti-fuel;


standard wooden case
Apr-23-21
Supplier From Pakistan
Jun-01-16
 
Place of Origin: Chongqing, China (Mainland)
Brand Name: TOP
Model Number: ACD-3000I
Power: Electronic
Usage: Auto Testing Machine
Type: Fully Automatic Oil Acidity Tester
Condition: New
Method of Display: 7 inch color LCD
Testing Range: 0.0005~0.5000mgKOH/g
Power supply: 220V±10%,50Hz±5%
Environmental Humidity:
Jul-26-18
 
FDT-0931 Automatic acid tester (extraction method)
Scope
This instrument is mainly used for measuring the acid value of petroleum products such as insulating oil and steam turbines. The instrument integrates optics, electronics, mechanical and electrical, chemical and other high-tech products. It has the characteristics of fast measurement, accuracy, reliability and good repeatability.

Features
1, large-screen LCD, English menu prompts, no identification keys;
2. Wrap Cup, automatic detection, automatic storage, automatic print test results;
3, the instrument can detect oil sample of six;
4, innovation introduced the US imports XECOM data processing chip, fast and accurate data processing;
5, the use of import VERDER accurate injection systems, precision control results progress;

Technical Parameters
1, supply voltage: ~ 220V ± 10% 50Hz
2, the maximum power consumption:
Jun-01-16
 
Technical Parameters
Method of Display 7 inch color touch LCD with English display
Method of Testing MPU controlled electrolysis(Karl Fischer Coulometric Method)
Rate of Electrolysis 2.4mgH2O/min
Electrolysis Current Auto-control within 430Ma
Testing Range 0.01ugH2O-200mgH2O
Water Content Range 0.0001%(1ppm)—100%
Sensitivity 0.01ugH2O
Accuracy Water Content: 2ugH2O-100ugH2O; Deviations=±1ug,
Water Content: 100ugH2O-1000ugH2O; Deviations=±2.9ug,
Water Content: >1000ugH2O; Deviations=±0.2%(excluding deviations of sample injection)     
Drift Compensation Auto-control via MPU
Stirring Speed Adjustable and steerable
End-point Indication LCD display /output via printing / voice warning / end-point indication light
Data Input Input via touch screen
Sample Number Numbered by users
Storage Infinite storage capacity
Printer Thermal printer, high-speed, low-consumption, with 44 millimeter-wide paper
Printing Content  ug / ppm / mg/L / sample number /experimenter / date
Calendar/Clock automatic display and print analyzing time and date
Self-checking Breakdown self-checking
Special Function Work independently or connected with laptop or other computers
Power Consumption <40W
Dimension 390×270×190mm
Working Environment Temperature: 5?-40?,Humidity: <85%
Power Supply AC220V±10% 50HZ±2.5HZ
Weight About 7kg

Application:
This TP-2100 water content tester adopts the global recognized classical moisture testing method - Karl Fischer Coulometric Method which is the most accurate method with low cost. With the universal standard and analyzing method, it can quickly analyze the moisture content in liquid, solid and gas and directly display testing results, with testing range from 0.0001%(1ppm) to 100%. Therefore, this testing method has been widely used in institutions and enterprises of petroleum, chemical industry, power, pharmaceuticals, pesticide, railways, research, etc.

Features:
1. Powerful Itanium and double CPU; direct A/D conversion of testing electrode data.
2. 7 inch color touch LCD display in English. Function of reagent failure prompt, extending the service time of it.
3. Completely closed titration system avoids direct touch between people and the reagent as well as the influence of environmental humidity.
4. The outer shell is made of high-quality cold-rolled steel plate with electrostatic sprayed surface, anti-corrosion and easy to clean.
5. Auto-control and compensation of electrical current via MCU contributes to quick balance of reagent.
6. Auto-control electrolysis current within 430mA ensures high sensitivity and fast analyzing speed.
7. Preinstalled with cubature (including 3 pieces of formula), statistical calculation (including average calculation, standard deviation calculation and rate of change calculation) and elementary arithmetic, with the advantages of auto-analysis and calculation.
Dec-17-21
 
Product description

Anti Emulsification performance automatic tester meets the requirement of GBT 7305-87 and GBT 7605-87, which adopts 32-bit high-performance microprocessor, high definition color touch screen and digital PID control algorithm to achieve high accuracy of temperature control, good repeatability, automatic lifting of stirrer, simultaneous test of four samples, smart storage and convenient check of test result.



Technical index

Temperature measurement Platinum resistance

Water bath temperature 54 Room temperature 100 can be set arbitrarily

Control accuracy 0.1

Stirring speed 1500 15 rmin

Number of cylinders 4

Self-check function Stirring device lifting and rotating

Display High definition color touch screen

Power supply AC 220V 22V

Power 1800VA

Frequency 50Hz 2.5Hz

Ambient temperature 10 35

Ambient humidity 85

Weight about 24kg

Profile size 358mm 302mm 858mm

Anti-emulsification performance automatic tester
Dec-22-14
Supplier From Changsha, Hunan, China
Jun-24-16
 
?equipment model and name
Csl-y impact specimen gap hydraulic broaching machine

? equipment usage
Impact specimen notch broaching machine is the dedicated and affiliated equipment with metallic pendulum impact testing machine, the machine adopts hydraulic drive, electric control the rise and fall of broach, broach lifting speed can be adjusted, adopting the lubricating oil to lubricate blade mouth parts at the same time, to ensure the sample accords with a requirement gap size and surface finish.The machine due to the use of a forming principle, the machining gap of good identity. Broach manufactured high-quality high-speed w18cr4v steel alloy, and its high hardness, good wear resistance, long service life, per knife can be processed more than 20000 samples.

? applicable standard
Gb/t229-2007« metal material charpy pendulum impact test method»;
Astm e23-02a«metal material gap specimen standard impact test method»;
Iso148-2008«metallic materials-charpy pendulum impact test»;
Din 50 115-1991«metal material impact test special sample size and fracture judge»

Iv main technical parameters
Sample notch type U type(u2, u3, u5), v type(v2)
Processing sample size 10×10(7.5 or 5)×55mm
Broach hardness =hrc65
Installed broach quantity 2
Cutting speed 2.5m/min ( can adjust)
System pressure 2.5mpa
Hysraulic oil storage 25l
Broach stroke 340mm(u2, v2), 390mm(u5)
Broach materials W18cv4v
Motor power 370w
Dimensions 480mm×660mm×1200mm (l×w×h)
Weight 200kg

V standard configuration
1.Host one
2.V2 broach one
3.U2 broach one

Vi optional accessories
1. U3 broach
2. U5 broach
Mar-19-06
Supplier From Jiangyan, Jiangsu, China
 
PH-903 Pen pH Tester WR

PH-903 Pen pH Tester WR (New)
Range: 0.00-f-¼14.00 pH,
Resolution: 0.01 pH,
Accuracy: -f+ú-f+¦0.03pH,
Temp. C: 5-f-¼50-f+¬, (ATC)
Calibration: Two-point at 6.86pH and 4.01pH (or 7.0pH and 4.01pH)
Features: Automatic switch-off function: After 10 minutes without pushing buttons, the meter will be switched off automatically.
Low battery: As long as there is any display, the accuracy is guaranteed.
Battery Life: DC 4x 1.5V
Flug: Fixed electrode


0

Verification Status