Technical Parameters
Method of Display 7 inch color touch LCD with English display
Method of Testing MPU controlled electrolysis(Karl Fischer Coulometric Method)
Rate of Electrolysis 2.4mgH2O/min
Electrolysis Current Auto-control within 430Ma
Testing Range 0.01ugH2O-200mgH2O
Water Content Range 0.0001%(1ppm)—100%
Sensitivity 0.01ugH2O
Accuracy Water Content: 2ugH2O-100ugH2O; Deviations=±1ug,
Water Content: 100ugH2O-1000ugH2O; Deviations=±2.9ug,
Water Content: >1000ugH2O; Deviations=±0.2%(excluding deviations of sample injection)
Drift Compensation Auto-control via MPU
Stirring Speed Adjustable and steerable
End-point Indication LCD display /output via printing / voice warning / end-point indication light
Data Input Input via touch screen
Sample Number Numbered by users
Storage Infinite storage capacity
Printer Thermal printer, high-speed, low-consumption, with 44 millimeter-wide paper
Printing Content ug / ppm / mg/L / sample number /experimenter / date
Calendar/Clock automatic display and print analyzing time and date
Self-checking Breakdown self-checking
Special Function Work independently or connected with laptop or other computers
Power Consumption <40W
Dimension 390×270×190mm
Working Environment Temperature: 5?-40?,Humidity: <85%
Power Supply AC220V±10% 50HZ±2.5HZ
Weight About 7kg
Application:
This TP-2100 water content tester adopts the global recognized classical moisture testing method - Karl Fischer Coulometric Method which is the most accurate method with low cost. With the universal standard and analyzing method, it can quickly analyze the moisture content in liquid, solid and gas and directly display testing results, with testing range from 0.0001%(1ppm) to 100%. Therefore, this testing method has been widely used in institutions and enterprises of petroleum, chemical industry, power, pharmaceuticals, pesticide, railways, research, etc.
Features:
1. Powerful Itanium and double CPU; direct A/D conversion of testing electrode data.
2. 7 inch color touch LCD display in English. Function of reagent failure prompt, extending the service time of it.
3. Completely closed titration system avoids direct touch between people and the reagent as well as the influence of environmental humidity.
4. The outer shell is made of high-quality cold-rolled steel plate with electrostatic sprayed surface, anti-corrosion and easy to clean.
5. Auto-control and compensation of electrical current via MCU contributes to quick balance of reagent.
6. Auto-control electrolysis current within 430mA ensures high sensitivity and fast analyzing speed.
7. Preinstalled with cubature (including 3 pieces of formula), statistical calculation (including average calculation, standard deviation calculation and rate of change calculation) and elementary arithmetic, with the advantages of auto-analysis and calculation.
Supplier: Solvent distillation plant , ethanol distillation plant , etp, water treatment plant , effluent treatment plant, evaporator , dryer, zld plant, lab equipment supplier, lab chemical supplier, industrial equipment , storage tank , bulk tank, petrochemical plant, ethyl acetate distillation plant, supplier of chemicals, reactor , pressure vessel , instruments, plc panel ,dcs panel, mcc panel , steam boiler, agitator tank, mixing tank, blending tank, bottling plant , vodka plant , ena distillation plant , fermentation plant , cooking plant, cpu plant, dg set, dpr report. etc, industrial dryer, industrial storage tanks, lab equipment, bio cng plant, biogas plant, bioreactor, sludge settling tank, wash settling tanks, pre fermenters, culture vessel, blender, blending tank, agitator, mixing tank, shell and tube heat exchanger, reboiler, reactor, mcc electrical panel, pressure vessel, evaporator, industrial dryer, beer plant, brewery plant, ethanol distillery , grain alcohol distiller plant
SANDI SERIES charging module is for electric vehicle charging station. With single-phase non neutral conductor AC input, it has the advantages of high efficiency, high power density and low harmonic. Functional details 1. Hot plug Plug technology is applied to the charging module to provide convenience for installation and maintenance. The access of the charging module to the system shall not disturb the output voltage of the system. 2. Advanced current sharing technology Under constant voltage working mode, the charging modules can share current automatically within 10S, with degree of unbalance less than �±0.5A. 3. Control of input limited power Refer to Fig. 1-10 for the relation between the output power and input voltage of the charging module. When the input voltage is within 360 Vac ~ 450 Vac (return difference is less than 5V), the module can output the maximum power of 20 KW; when the input voltage is within 260 Vac ~ 320 Vac, the module can still work normally under limited power mode. 4. Control of output constant power When there is a rated input voltage, the output power of the module is 20 KW. Refer to Fig. 11 for the relation between the output voltage and the output current of the module. The SD75050 module uses two operating modes with output voltage ranges of 50 to 750V. The module only selects the operating mode based on the value of the received demand voltage, and does not select the operating mode based on the actual output voltage. 5. Temperature limited power 6. Regulation of output current limiting point 8. Regulation of output voltage The output voltage of the module can be regulated constantly through the external monitoring module, with regulation range of 50Vdc ~ 750Vdc and minimum regulation step of 0.1 Vdc. 9. Fan control The built-in processor of the module can regulate the speed of the fan according to the internal temperature and output current of the module. 10. Protection of input overvoltage/ voltage shortage 11. Output overvoltage protection The overvoltage protection point is 260Vdc ~770Vdc (�±10 Vdc). Default is 778Vdc.The module can be started after manual intervention upon overvoltage protection. 12. Over-temperature protection The environmental over-temperature protection point is 80�°C. When the DC panel has a temperature over 100�°C, the module will stop working; when the DC panel has a temperature below 90�°C, the module will automatically work again. 13. Protection of internal bus fault When the internal bus voltage of the module is beyond the overvoltage/ voltage shortage protection point, the module will be powered off automatically. At this time, there is no output from the module and the fault indicator light is on. 14. Short circuit protection In case of short circuit of the module, it will be subjected to protective shutdown and the red indicator light of the panel is on, and this condition will be transmitted to the monitor of the "module fault".
Supplier: Agriculture product and garment product, marine oil, ship engine oil low sulphur fuel, propulsion oil, high sulphur fuel, gl4 oil, water resistant oil, cycle rickshaw & thela, stabilizer, electronic voltage corrector
Floating cable which can be applied to underwater robot equipment, either in fresh water environment or in seawater environment. It is widely used in marine exploration robot, underwater ROV UAV remote control submersible, underwater camera, underwater construction, underwater search and rescue robot, pipeline detection robot, submersible pump and the link between various underwater electrical equipment and shore based equipment; Link of signal transmission, power supply and equipment control system from underwater to water.
Application :- These single core flexible cables are used for wiring in control panels, machines and various electrical installations In small, medium and large industries. Features :- Manufactured from bright annealed 99.97% pure bare copper conductors, these cables have low conductor resistance. These wires are insulated with a special grade PVC compound formulated and manufactured in-house which is impervious to water, oil, grease, acids, etc. and are tough to protect from any mechanical abuses. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C Sizes : 0.50 to 50.00 Sq. mm with ISI mark & 70.0 to 40.0 Sq. mm generally conforming to IS:694 Color Codes : Red, Yellow, Blue, Black, Grey, White, Pink, Green, Violet, Brown, Orange Specification : IS:694 Packing : In 90 meter coils, higher sizes in drums.
Instrumentation circuits cable is used for computer based automatic control system, especially for computer distributed control system, transmission of production device process variable detection, control, interlocking, alarm lamp analog and digital signals, the product has excellent anti-interference performance, long-term working temperature -40~105.
6-35kv medium vollage power cable selection with cross-linked polyethylene insulation and plastic Sheath material, insulation layer USES the three co-extrusion technology, full automatic Change control. Such products, aging resistance, corrosion resistance, environmental stress not only electricity Gas properties and good mechanical properties, and has a simple structure and outer diameter Small, light weight, easy to use and elaborate divide not restricted, Public places such as crowed, place closed space.
Inverter cables is mainly used as power supply cable or connecting cable in frequency control drive system. This kind of cable is especially suitable for transmission machine and transmission line of automatic production line of iron and steel, petrochemical, power plant, paper making, textile, metal processing and food processing, as well as all kinds of pressure pump, blower and centralized air conditioning. The shielding layer of the Inverter cable has the function of uniform electric field and improving the electromagnetic radiation level of the cable; At the same time, the product has excellent anti-interference performance.