Features:
1. Supply Voltage: Loop Power 18~32 Vdc
2. DCV Input: 0~500 mV/ 0~1V/ 0~5V/ 0~10V/ 0~20V
3. DCA Input: 0~20 mA/ 4~20 mA
4. Thermocouple Input: K / J / T / E / R / S / B / N
5. RTD/ Resistance Input: PT100/0~400W
6. Analog Output: 4~20 mA (Loop Power)
7. Ambient temperature: -20~60°C
8. Communication: HART
9. Galvanic Isolation: 1500V
Specification: 1.Supply voltage: loop power 18~32 vdc 2.Dcv input: 0~500 mv/ 0~1v/ 0~5v/ 0~10v/ 0~20v 3.Dca input: 0~20 ma/ 4~20 ma 4.Thermocouple input: k / j / t / e / r / s / b / n 5.Rtd/ resistance input: pt100/0~400w 6.Analog output: 4~20 ma (loop power) 7.Ambient temperature: -20~60c 8.Communication: hart 9.Galvanic isolation: 1500v Feature: 1.Isolation voltage: 1500 vac 2.Loop power 12~32vdc 3.Linear current output 4.Lcd display with 3 press buttons 5.Universal type with multi-signal input 6.With communication port for programming 7.Optional: hart Transmitter
Features: Designed for industrial application. Resistant to high temperature and high pressure. Sensor type: Capacitive Humidity Sensor & Pt 100 A class Measuring range: 0 . +180C Output: 0 . 20 mA / 4 . 20 mA / 0 ... 10 V Accuracy: Temperature 0.15 C / Humidity 2%RH IP rating: IP65
High precision temperature transmission Optimized for precision industry Configurable analog signal transmission (4-20mA) Communication via RS485 MODBUS (PC-HMI and PLC) Built-in LCD Simple and sleek design
Features: 1. Real-time monitoring of grain temperature to prevent spoilage 2. 1-wire digital temperature sensors 3. Unique temperature/level (EST120) monitoring cable 4. 98.5ft (30m) maximum cable length 5. Customizable number and location of temperature sensors 6. Simplified and lower installation costs using digital technology, wired or wireless 7. Operator interface with remote monitoring PC-software
MS182 is a smart in-head transmitter module with HART® -protocol. It has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection, and converts various input signals into a standard 4 to 20 mA analog output signal after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use PC or the hand operator Measuring range Set via PC or by the hand operator Input type RTD, TC, R or Millivolt signal Convert accuracy 0.1£¥FS Cold junction accuracy ¡À1(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output HART ¨CProtocol output Max-load £¨V -13V£©/0.025A£¨Current output £© Limit current 25mA Response time 1s Isolated voltage 1500V AC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: 3.6mA or ¡Ý21.0mA Power supply 13¡«30V DC Temperature drift 0.01£¥ FS/1 Long-term stability 0.1 per year or 0.05 £¥per year Ambient -40¡«+85.
MS181 is an intelligent temperature transmitter module which can be programmed through a PC with Configuration Kit. It has measurement input for resistance thermometers (RTD) ,thermocouples, resistances or millivolt signals in 2-,3- or 4-wire connection, and converts various input signals into a 4~ 20mA analog output signal after linear processing. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use the MS181 programming tool Measuring range Set via PC PC Interface USB/RS232 Input type RTD, TC, R or Millivolt signal Convert accuracy ¡Ü0.1£¥FS Cold junction accuracy ¡À1(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output Max-load £¨V -8V£©/0.025A£¨Current output £© Limit current ¡Ü25mA Response time 1s Isolated voltage 1500V AC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: ¡Ü3.6mA or¡Ý21.0mA Power supply 8¡«30V DC Temperature drift 0.01£¥ FS / 1 Long-term stability ¡Ü0.1 per year or 0.05£¥ per year Ambient -40¡«+85
MS183 , a smart 2-wire in-head and dual-input transmitter module with HART® -protocol, has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection and converts various input signals into a standard 4 to 20 mA analog(high selector, average value or D-value) output signal or 2-way digtal output signals with HART® -protocol after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation also is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use PC or the hand operator Measuring range Set via PC or by the hand operator Input type Dual-input ( RTD, TC, R or Millivolt signal) Convert accuracy ¡Ü0.1£¥FS Cold junction accuracy ¡À1¡æ(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output HART ¨CProtocol output (2-way) Max-load £¨V -16V£©/0.025A£¨Current output £© Limit current ¡Ü25mA Response time 1s Isolated voltage 1500VAC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: ¡Ü3.6mA or ¡Ý21.0mA Automatic switching while sensor damaged Power supply 16¡«30V DC Temperature drift 0.01£¥ FS/1¡æ Long-term stability ¡Ü0.1¡æ per year or 0.05 £¥per year.
• Universal PC programmable (PCP) • 2 wire technology, 4 to 20 mA analogue output • High accuracy in total ambient temperature range • Configuration during measurement using configuration kit • Customer specific measurement range setting • Wide measurement range, according to requirement Field of application • PC programmable (PCP) Temperature head transmitter for converting the input signal into a standard 4 to 20 mA analog output signal • Input: Resistance thermometer (RTD) Pt100 • Configuration using a PC with MS180 configuration kit (MS180-PC). Appearance and Size (in mm) NOTE: When order, please specify the measuring range, we’ll offer programming tool if needed.
Humidity and temperature sensor transmitter Digital frequential ouput Nominal frequency 6.5 khz Std sensitivity 13 hz/%rh Response time 0.3 s Response time with Optional protection : 20 s Accurcy-interchangeability : 3 %hr de 3 a 97%rh Hysttrtsis