Features:
1. Real-time monitoring of grain temperature to prevent spoilage
2. 1-wire digital temperature sensors
3. Unique temperature/level (EST120) monitoring cable
4. 98.5ft (30m) maximum cable length
5. Customizable number and location of temperature sensors
6. Simplified and lower installation costs using digital technology, wired or wireless
7. Operator interface with remote monitoring PC-software
High precision temperature transmission Optimized for precision industry Configurable analog signal transmission (4-20mA) Communication via RS485 MODBUS (PC-HMI and PLC) Built-in LCD Simple and sleek design
MS182 is a smart in-head transmitter module with HART® -protocol. It has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection, and converts various input signals into a standard 4 to 20 mA analog output signal after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use PC or the hand operator Measuring range Set via PC or by the hand operator Input type RTD, TC, R or Millivolt signal Convert accuracy 0.1£¥FS Cold junction accuracy ¡À1(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output HART ¨CProtocol output Max-load £¨V -13V£©/0.025A£¨Current output £© Limit current 25mA Response time 1s Isolated voltage 1500V AC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: 3.6mA or ¡Ý21.0mA Power supply 13¡«30V DC Temperature drift 0.01£¥ FS/1 Long-term stability 0.1 per year or 0.05 £¥per year Ambient -40¡«+85.
MS181 is an intelligent temperature transmitter module which can be programmed through a PC with Configuration Kit. It has measurement input for resistance thermometers (RTD) ,thermocouples, resistances or millivolt signals in 2-,3- or 4-wire connection, and converts various input signals into a 4~ 20mA analog output signal after linear processing. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use the MS181 programming tool Measuring range Set via PC PC Interface USB/RS232 Input type RTD, TC, R or Millivolt signal Convert accuracy ¡Ü0.1£¥FS Cold junction accuracy ¡À1(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output Max-load £¨V -8V£©/0.025A£¨Current output £© Limit current ¡Ü25mA Response time 1s Isolated voltage 1500V AC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: ¡Ü3.6mA or¡Ý21.0mA Power supply 8¡«30V DC Temperature drift 0.01£¥ FS / 1 Long-term stability ¡Ü0.1 per year or 0.05£¥ per year Ambient -40¡«+85
MS183 , a smart 2-wire in-head and dual-input transmitter module with HART® -protocol, has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection and converts various input signals into a standard 4 to 20 mA analog(high selector, average value or D-value) output signal or 2-way digtal output signals with HART® -protocol after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation also is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use PC or the hand operator Measuring range Set via PC or by the hand operator Input type Dual-input ( RTD, TC, R or Millivolt signal) Convert accuracy ¡Ü0.1£¥FS Cold junction accuracy ¡À1¡æ(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output HART ¨CProtocol output (2-way) Max-load £¨V -16V£©/0.025A£¨Current output £© Limit current ¡Ü25mA Response time 1s Isolated voltage 1500VAC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: ¡Ü3.6mA or ¡Ý21.0mA Automatic switching while sensor damaged Power supply 16¡«30V DC Temperature drift 0.01£¥ FS/1¡æ Long-term stability ¡Ü0.1¡æ per year or 0.05 £¥per year.
• Universal PC programmable (PCP) • 2 wire technology, 4 to 20 mA analogue output • High accuracy in total ambient temperature range • Configuration during measurement using configuration kit • Customer specific measurement range setting • Wide measurement range, according to requirement Field of application • PC programmable (PCP) Temperature head transmitter for converting the input signal into a standard 4 to 20 mA analog output signal • Input: Resistance thermometer (RTD) Pt100 • Configuration using a PC with MS180 configuration kit (MS180-PC). Appearance and Size (in mm) NOTE: When order, please specify the measuring range, we’ll offer programming tool if needed.
Humidity and temperature sensor transmitter Digital frequential ouput Nominal frequency 6.5 khz Std sensitivity 13 hz/%rh Response time 0.3 s Response time with Optional protection : 20 s Accurcy-interchangeability : 3 %hr de 3 a 97%rh Hysttrtsis
- Integrated module with temperature, humidity sensor - Up to 100 nodes can be connected (RS485 models) - Compact design, slim size - Easy installation, offer 3 meter cable - Support the various types of communications protocol
Specification: 1.Supply voltage: loop power 18~32 vdc 2.Dcv input: 0~500 mv/ 0~1v/ 0~5v/ 0~10v/ 0~20v 3.Dca input: 0~20 ma/ 4~20 ma 4.Thermocouple input: k / j / t / e / r / s / b / n 5.Rtd/ resistance input: pt100/0~400w 6.Analog output: 4~20 ma (loop power) 7.Ambient temperature: -20~60c 8.Communication: hart 9.Galvanic isolation: 1500v Feature: 1.Isolation voltage: 1500 vac 2.Loop power 12~32vdc 3.Linear current output 4.Lcd display with 3 press buttons 5.Universal type with multi-signal input 6.With communication port for programming 7.Optional: hart Transmitter
We offer stand-alone Environmental monitoring appliance that provides dynamic, real-time temperature monitoring, humidity monitoring for server room, Datacentre and computer rooms or any critical environment. It has following features: 1) Real time monitoring of Humidity and Temperature. 2) Includes dry contact for alarms from critical equipment include power monitoring, water sensors, smoke and fire alarms, motion detectors, airflow, and access/entry sensors. 3) Permits remote monitoring of temperature, humidity and digital dry contact. 4) Notification of alarms via email, SMS, SNMP traps when specified temperature and humidity thresholds or the change of status of a digital dry contact signal 5) Simple integration to a Building Management System (BMS). 6) Capable of Modbus over TCP/IP. Built-in Web server. 7) Option of additional humidity & Temperature sensor. 8) Datacenter & Server room Environment monitoring & control. We also offer Facility Monitoring system (FMS) equipment which extreme versatility that simplifies and consolidates monitoring of numerous types of signals and equipment available at facilities. These equipments can be UPS, water leak detection, Close control unit (CCU), access control or any equipment that has dry contact etc. Environmental monitoring, humidity monitoring, temperature monitoring, humidity & temperature monitoring, datacenter, server room, server room, rle, enviromux, nti, liebert, APC, netboltz, Aqualeak, SecurityProbe, openxtra, server room monitoring