Please click here to check who's online and chat with them.

Temperature & Level Monitoring Transmitter

Supplier From Taiwan
Mar-30-16

Features:

1. Real-time monitoring of grain temperature to prevent spoilage
2. 1-wire digital temperature sensors
3. Unique temperature/level (EST120) monitoring cable
4. 98.5ft (30m) maximum cable length
5. Customizable number and location of temperature sensors
6. Simplified and lower installation costs using digital technology, wired or wireless
7. Operator interface with remote monitoring PC-software


Recent User Reviews

This user has not received any reviews yet!

Verification Status


 
 
Contact Supplier
Renew

More Items Similiar to: Temperature & Level Monitoring Transmitter

Nov-01-16
Supplier From Ansan-si, South Korea (Republic Of Korea)
 
High precision temperature transmission
Optimized for precision industry
Configurable analog signal transmission (4-20mA)
Communication via RS485 MODBUS (PC-HMI and PLC)
Built-in LCD
Simple and sleek design
Oct-17-11
 
MS182 is a smart in-head transmitter module with HART® -protocol. It has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection, and converts various input signals into a standard 4 to 20 mA analog output signal after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short.
Primary Technical Characteristics
Programmable Use PC or the hand operator
Measuring range Set via PC or by the hand operator
Input type RTD, TC, R or Millivolt signal
Convert accuracy 0.1£¥FS
Cold junction accuracy ¡À1(TC)
Output 4¡«20mA/20¡«4mA Electrical isolation output
HART ¨CProtocol output
Max-load £¨V -13V£©/0.025A£¨Current output £©
Limit current 25mA
Response time 1s
Isolated voltage 1500V AC (input/output)
Alarm signal Programmable
Underranging linear drop to 3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit:
3.6mA or ¡Ý21.0mA
Power supply 13¡«30V DC
Temperature drift 0.01£¥ FS/1
Long-term stability 0.1 per year or 0.05 £¥per year
Ambient -40¡«+85.
Oct-17-11
 
MS181 is an intelligent temperature transmitter module which can be programmed through a PC with Configuration Kit. It has measurement input for resistance thermometers (RTD) ,thermocouples, resistances or millivolt signals in 2-,3- or 4-wire connection, and converts various input signals into a 4~ 20mA analog output signal after linear processing. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short.
Primary Technical Characteristics
Programmable Use the MS181 programming tool
Measuring range Set via PC
PC Interface USB/RS232
Input type RTD, TC, R or Millivolt signal
Convert accuracy ¡Ü0.1£¥FS
Cold junction accuracy ¡À1(TC)
Output 4¡«20mA/20¡«4mA Electrical isolation output
Max-load £¨V -8V£©/0.025A£¨Current output £©
Limit current ¡Ü25mA
Response time 1s
Isolated voltage 1500V AC (input/output)
Alarm signal Programmable
Underranging linear drop to 3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit:
¡Ü3.6mA or¡Ý21.0mA
Power supply 8¡«30V DC
Temperature drift 0.01£¥ FS / 1
Long-term stability ¡Ü0.1 per year or 0.05£¥ per year
Ambient -40¡«+85
Oct-17-11
 
MS183 , a smart 2-wire in-head and dual-input transmitter module with HART® -protocol, has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection and converts various input signals into a standard 4 to 20 mA analog(high selector, average value or D-value) output signal or 2-way digtal output signals with HART® -protocol after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation also is provided between the input and output. A special signal can be set in advance while the sensor burnout or short.
Primary Technical Characteristics
Programmable Use PC or the hand operator
Measuring range Set via PC or by the hand operator
Input type Dual-input ( RTD, TC, R or Millivolt signal)
Convert accuracy ¡Ü0.1£¥FS
Cold junction accuracy ¡À1¡æ(TC)
Output 4¡«20mA/20¡«4mA Electrical isolation output
HART ¨CProtocol output (2-way)
Max-load £¨V -16V£©/0.025A£¨Current output £©
Limit current ¡Ü25mA
Response time 1s
Isolated voltage 1500VAC (input/output)
Alarm signal Programmable
Underranging linear drop to 3.8 mA
Overranging linear rise to 20.5 mA
Sensor break or short-circuit:
¡Ü3.6mA or ¡Ý21.0mA
Automatic switching while sensor damaged
Power supply 16¡«30V DC
Temperature drift 0.01£¥ FS/1¡æ
Long-term stability ¡Ü0.1¡æ per year or 0.05 £¥per year.
Oct-17-11
 
• Universal PC programmable (PCP)
• 2 wire technology, 4 to 20 mA analogue output
• High accuracy in total ambient temperature range
• Configuration during measurement using configuration kit
• Customer specific measurement range setting
• Wide measurement range, according to requirement
Field of application
• PC programmable (PCP) Temperature head transmitter for converting the input signal into a standard 4 to 20 mA analog output signal
• Input: Resistance thermometer (RTD) Pt100
• Configuration using a PC with MS180 configuration kit (MS180-PC).



Appearance and Size (in mm)

NOTE: When order, please specify the measuring range, we’ll offer programming tool if needed.
Jan-31-06
Supplier From Champigny Marne, France
 
Humidity and temperature sensor transmitter
Digital frequential ouput
Nominal frequency 6.5 khz
Std sensitivity 13 hz/%rh
Response time 0.3 s
Response time with
Optional protection : 20 s
Accurcy-interchangeability :
3 %hr de 3 a 97%rh
Hysttrtsis <1.5%rh
Measurement range 0 a 100 %hr
Operating range : -40ªc a +80ªc
Supply voltage : 4 a 12v
Ouput resistor : 0, 2 k
Output courant : ª2 ma
Thermistance ntc 10 k a 25ªc
Operating range : -40ªc a +80ªc
Courant max : 0.3 ma

8x9x4 mm3
Nov-01-16
Supplier From Ansan-si, South Korea (Republic Of Korea)
 
- Integrated module with temperature, humidity sensor
- Up to 100 nodes can be connected (RS485 models)
- Compact design, slim size
- Easy installation, offer 3 meter cable
- Support the various types of communications protocol
Jul-12-17
 
Specification:
1.Supply voltage: loop power 18~32 vdc
2.Dcv input: 0~500 mv/ 0~1v/ 0~5v/ 0~10v/ 0~20v
3.Dca input: 0~20 ma/ 4~20 ma
4.Thermocouple input: k / j / t / e / r / s / b / n
5.Rtd/ resistance input: pt100/0~400w
6.Analog output: 4~20 ma (loop power)
7.Ambient temperature: -20~60c
8.Communication: hart
9.Galvanic isolation: 1500v

Feature:
1.Isolation voltage: 1500 vac
2.Loop power 12~32vdc
3.Linear current output
4.Lcd display with 3 press buttons
5.Universal type with multi-signal input
6.With communication port for programming
7.Optional: hart

Transmitter
Sep-04-19

Temperature And Humidity Monitoring

$12.00K
MOQ: Not Specified
Supplier From Sharjah, Dubai, United Arab Emirates
 
We offer stand-alone Environmental monitoring appliance that provides dynamic, real-time temperature monitoring, humidity monitoring for server room, Datacentre and computer rooms or any critical environment. It has following features:

1) Real time monitoring of Humidity and Temperature.
2) Includes dry contact for alarms from critical equipment include power monitoring, water sensors, smoke and fire alarms, motion detectors, airflow, and access/entry sensors.
3) Permits remote monitoring of temperature, humidity and digital dry contact.
4) Notification of alarms via email, SMS, SNMP traps when specified temperature and humidity thresholds or the change of status of a digital dry contact signal
5) Simple integration to a Building Management System (BMS).
6) Capable of Modbus over TCP/IP. Built-in Web server.
7) Option of additional humidity & Temperature sensor.
8) Datacenter & Server room Environment monitoring & control.

We also offer Facility Monitoring system (FMS) equipment which extreme versatility that simplifies and consolidates monitoring of numerous types of signals and equipment available at facilities. These equipments can be UPS, water leak detection, Close control unit (CCU), access control or any equipment that has dry contact etc. Environmental monitoring, humidity monitoring, temperature monitoring, humidity & temperature monitoring, datacenter, server room, server room, rle, enviromux, nti, liebert, APC, netboltz, Aqualeak, SecurityProbe, openxtra, server room monitoring

Verification Status