MS181 is an intelligent temperature transmitter module which can be programmed through a PC with Configuration Kit. It has measurement input for resistance thermometers (RTD) ,thermocouples, resistances or millivolt signals in 2-,3- or 4-wire connection, and converts various input signals into a 4~ 20mA analog output signal after linear processing. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use the MS181 programming tool Measuring range Set via PC PC Interface USB/RS232 Input type RTD, TC, R or Millivolt signal Convert accuracy ¡Ü0.1£¥FS Cold junction accuracy ¡À1(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output Max-load £¨V -8V£©/0.025A£¨Current output £© Limit current ¡Ü25mA Response time 1s Isolated voltage 1500V AC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: ¡Ü3.6mA or¡Ý21.0mA Power supply 8¡«30V DC Temperature drift 0.01£¥ FS / 1 Long-term stability ¡Ü0.1 per year or 0.05£¥ per year Ambient -40¡«+85
MS183 , a smart 2-wire in-head and dual-input transmitter module with HART® -protocol, has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection and converts various input signals into a standard 4 to 20 mA analog(high selector, average value or D-value) output signal or 2-way digtal output signals with HART® -protocol after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation also is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use PC or the hand operator Measuring range Set via PC or by the hand operator Input type Dual-input ( RTD, TC, R or Millivolt signal) Convert accuracy ¡Ü0.1£¥FS Cold junction accuracy ¡À1¡æ(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output HART ¨CProtocol output (2-way) Max-load £¨V -16V£©/0.025A£¨Current output £© Limit current ¡Ü25mA Response time 1s Isolated voltage 1500VAC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: ¡Ü3.6mA or ¡Ý21.0mA Automatic switching while sensor damaged Power supply 16¡«30V DC Temperature drift 0.01£¥ FS/1¡æ Long-term stability ¡Ü0.1¡æ per year or 0.05 £¥per year.
• Universal PC programmable (PCP) • 2 wire technology, 4 to 20 mA analogue output • High accuracy in total ambient temperature range • Configuration during measurement using configuration kit • Customer specific measurement range setting • Wide measurement range, according to requirement Field of application • PC programmable (PCP) Temperature head transmitter for converting the input signal into a standard 4 to 20 mA analog output signal • Input: Resistance thermometer (RTD) Pt100 • Configuration using a PC with MS180 configuration kit (MS180-PC). Appearance and Size (in mm) NOTE: When order, please specify the measuring range, we’ll offer programming tool if needed.
MS182 is a smart in-head transmitter module with HART® -protocol. It has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection, and converts various input signals into a standard 4 to 20 mA analog output signal after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use PC or the hand operator Measuring range Set via PC or by the hand operator Input type RTD, TC, R or Millivolt signal Convert accuracy 0.1£¥FS Cold junction accuracy ¡À1(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output HART ¨CProtocol output Max-load £¨V -13V£©/0.025A£¨Current output £© Limit current 25mA Response time 1s Isolated voltage 1500V AC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: 3.6mA or ¡Ý21.0mA Power supply 13¡«30V DC Temperature drift 0.01£¥ FS/1 Long-term stability 0.1 per year or 0.05 £¥per year Ambient -40¡«+85.
MS150 Series multi-channel temperature monitor is a multi-point temperature measurement instrument. It takes the highest measured temperature in measuring loops as its output signal which is sent out in the form of a 4 to 20 mA standard current signal and the temperature is displayed by the built-in LED. If required, temperature at any measuring point can be shown by operating the keys on panel. Isolation is provided between the input and output. It is mainly used in the applications of multi-point temperature measurement or alarm warning system. By adopting SMT technology, it offers excellent accuracy, reliability and anti-disturbance. Primary Technical Characteristics Measuring range 0¡«100¡æ¡¢0¡«150¡æ¡¢0¡«200¡æ £¨according to user's demand£© Input type Pt100,Cu50£¨TC if specially required£© Measuring Points 2,3,4,5,6 points Convert accuracy ¡Ü0.5£¥FS linearity error < 0.1% Output 4¡«20mA Electrical isolation output Digital display LED Display accuracy 0.5% Voltage drop for display 3V Isolated voltage Drop 2V Isolate Voltage 1500V AC (Input/Output¡¢with isolator) Max-load £¨V -14V~16V£©/0.025A£¨Current output £© Limit current ¡Ü25mA Response time 1s Power supply 14~30V DC Temperature draft 0.025% FS/ 1¡æ Long-term stability ¡Ü0.1¡æper year or 0.05£¥ per year Ambient -40~+85¡æ£¨Aluminium alloy .Casing£© -25 ~+75¡æ£¨Plastic Casing£© Protection level IP66£¨Aluminium alloy£©/IP62£¨Plastic£© Anti-RFI >10v/m(80MHz¡¡1000MHz).
1. Current overload or line surge shutdown 2. High temperature compressor shutdown. 3. High pressure alarm shutdown. 4. Low pressure alarm shutdown. 5. Low oxygen cocentrator alarm. Oxygen concentrator: 0.5-5L/min Purity: 95%+_3% Working system Continuous Power Supply AC230V.50Hz/AC220V.60HZ AC120V.60Hz Power: 390VA Net Weight: 16kg( Gross weight: 18.5kgs) Warranty: Long-life compressor designed for 1000 hours of maintenance-free use. Size: 33*26*54cm
Product's name: Wood Charcoal Keywords: Flat cube charcoal,Flat cube burning,Lump charcoal , Lump Shisha Charcoal, Silver Charcoal. Specification as following: Specification: Grade A Material (Composition) 90% bamboo charcoal & 10% pure nature bonding Moisture Content less than 6% Fixed Carbon More than 85% Ash 4% Heat value 7000J-8000J Volatile Matter 2% Hardness 90% Temperature (Burning) 700-880°C Burning Time 4-5 hours Others feature smokeless,odourless,innocuity, no bursting it is an environment-friendly products , no any chemicals Size: hexagon shape square diameter outer diameter Æ 40mm 40x40mm inner diameter Æ 10mm Æ 10mm Length 18-25cm 18-25cm Weight (Average) 285g-295/pc 285-295g/pc
Specifications 1.odorless 2.low VOC 3.antimicrobial 4. mildew resistant 5.environmentally friendly 6.waterproof 7.Scrub resistance Description It is an enhanced mildew proof product adopting nano-scale Ag+ antimicrobial and mildew proof technology, integrating odorless formula, with fresh product smell, smooth paint film, durable and beautiful paint.As an affordable and environmentally friendly product with excellent decorative performance, it is characterized by fresh smell, environmental health, strong covering power, large painting area, convenient constructionapplication, short constructionapplication period, etc. Specification Data Solvent: Water Pigment: Non-lead pigment Theoretical Solids By Volume: more than 50% Theoretical Coverage: Theoretically 1 litre of this product covers 12 sqm in 1 coat Coverage varies considerably depending on application methods and surface roughness and porosity. Shelf Life: Minimum 12 months at 77F(25C) unopened and store in cool and dry places. Recommended Film Thickness: Wet: 80 micron Dry: 30 micron Dry Time: At 77F (25C) and 50% R.H. to recoat Touch Dry: 1 hours Recoat : 2-3 hours Application: Brush, Roll, conventional spray or Airless Spray. Thinner: Thin up 15% depend on different application methods & temperature. Do not over thin by adding more than 30% water. Brush or Roller: For sealing new or bare surfaces thin with up to 1 part of clean water to 5-10 parts of paint(10%-20%) Conventional Spray: Add up to 1 part clean water to 5 parts paint(20%) Airless spray: do not thin Clean-up: Clean up equipment with water Typical painting system Substrate System All kinds of Wall surfaces 1.Alkali Resistance Primer (1 coat) 2.Emulsion Wall Paint (2 coats)