• Universal PC programmable (PCP)
• 2 wire technology, 4 to 20 mA analogue output
• High accuracy in total ambient temperature range
• Configuration during measurement using configuration kit
• Customer specific measurement range setting
• Wide measurement range, according to requirement
Field of application
• PC programmable (PCP) Temperature head transmitter for converting the input signal into a standard 4 to 20 mA analog output signal
• Input: Resistance thermometer (RTD) Pt100
• Configuration using a PC with MS180 configuration kit (MS180-PC).
Appearance and Size (in mm)
NOTE: When order, please specify the measuring range, we’ll offer programming tool if needed.
MS181 is an intelligent temperature transmitter module which can be programmed through a PC with Configuration Kit. It has measurement input for resistance thermometers (RTD) ,thermocouples, resistances or millivolt signals in 2-,3- or 4-wire connection, and converts various input signals into a 4~ 20mA analog output signal after linear processing. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use the MS181 programming tool Measuring range Set via PC PC Interface USB/RS232 Input type RTD, TC, R or Millivolt signal Convert accuracy ¡Ü0.1£¥FS Cold junction accuracy ¡À1(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output Max-load £¨V -8V£©/0.025A£¨Current output £© Limit current ¡Ü25mA Response time 1s Isolated voltage 1500V AC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: ¡Ü3.6mA or¡Ý21.0mA Power supply 8¡«30V DC Temperature drift 0.01£¥ FS / 1 Long-term stability ¡Ü0.1 per year or 0.05£¥ per year Ambient -40¡«+85
MS183 , a smart 2-wire in-head and dual-input transmitter module with HART® -protocol, has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection and converts various input signals into a standard 4 to 20 mA analog(high selector, average value or D-value) output signal or 2-way digtal output signals with HART® -protocol after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation also is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use PC or the hand operator Measuring range Set via PC or by the hand operator Input type Dual-input ( RTD, TC, R or Millivolt signal) Convert accuracy ¡Ü0.1£¥FS Cold junction accuracy ¡À1¡æ(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output HART ¨CProtocol output (2-way) Max-load £¨V -16V£©/0.025A£¨Current output £© Limit current ¡Ü25mA Response time 1s Isolated voltage 1500VAC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: ¡Ü3.6mA or ¡Ý21.0mA Automatic switching while sensor damaged Power supply 16¡«30V DC Temperature drift 0.01£¥ FS/1¡æ Long-term stability ¡Ü0.1¡æ per year or 0.05 £¥per year.
MS182 is a smart in-head transmitter module with HART® -protocol. It has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection, and converts various input signals into a standard 4 to 20 mA analog output signal after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use PC or the hand operator Measuring range Set via PC or by the hand operator Input type RTD, TC, R or Millivolt signal Convert accuracy 0.1£¥FS Cold junction accuracy ¡À1(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output HART ¨CProtocol output Max-load £¨V -13V£©/0.025A£¨Current output £© Limit current 25mA Response time 1s Isolated voltage 1500V AC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: 3.6mA or ¡Ý21.0mA Power supply 13¡«30V DC Temperature drift 0.01£¥ FS/1 Long-term stability 0.1 per year or 0.05 £¥per year Ambient -40¡«+85.
Product Overview NCS-TT106 smart temperature module, using the fieldbus technology, is a new generation of smart fieldbus temperature transmitter and it is an indispensable field device for process control. Features Support multiple thermal resistance and thermocouples Thermal resistance supports 2/3/4-wire connection mode Thermocouple can use cold end compensation function Better accuracy: PT100 ±0.3 ; K-type ±0.4 Universally programmable for various input signals Available protocols: HART /FF H1 /PROFIBUS PA Parameter Value Input Signal Resistance: PT100, CU50, CU100, 0~500Ω, 0~4000Ω Thermocouple: B, E, J, N, K, R, S, T Voltage signal: -100mV~100mV Channel Single RTD Wiring 2-wire, 3-wire, 4-wire Bus Power 9~32 VDC Current consumption (static): â?¤14mA Bus Signal Communication ratio 31.25Kbit/s, current mode Isolation Between terminal and housing: 1kV Working Temperature -40~85 Humidity Range 10%~90%RH Start Time â?¤5s Refresh Time 0.5s EMC GB/T 18268-2000 Protection IP20 Signal Type Suggested Range () Accuracy Resistance 0~500Ω,0~4000Ω ±0.05% PT100 -200 ~ 850 ±0.2 PT1000 -200~ 850 ±0.1 CU50 -50 ~ 150 ±0.3 CU100 -50 ~ 150 ±0.2 mV -100mV ~ 100mV 0.05% B 500 ~ 1810 ±1.0 E -200 ~ 1000 ±0.4 J -190 ~ 1200 ±0.4 K -200 ~ 1372 ±0.4 N -190 ~ 1300 ±0.8 R 0 ~ 1768 ±1.0 S 0 ~ 1768 ±1.0 T -200 ~ 400 ±0.4
The ZP series Temperature Transmitter is designed to meet common Single Point measurement application requirements. This transmitter can easily work with a variety of sensors (RTDs and thermocouples) and thermowells. It provided in a head mount configuration suitable for installation in a wide variety of connection heads and housings. A PC-programmable interface is available, providing an easy-to-use configuration method from any PC. Basic temperature transmitter offers a reliable solution for temperature monitoring points, provides flexible and reliable performance in process environments, Excellent performance with low temperature drift and auto zero calibration, reducing the need for expensive extension wires and multiplexers. Power Supply 8.5VDC~32VDC Input Types 4-20mA / 20-4mA; RTD(PT100,PT200,PT500,PT1000,Cu50); R(0-400 ,0-4000 ); TC(K,E,S,B,R,J,T,N); mV(-80-+80mV); V(0-1V) Output signal types 4-20mA or 0...1/5V, 0...1/10V Response Time < 0.4S (0-90%,100%-10%) Precision �±0.05% Temp. Drift 0.01% per Celsius Volt fluctuation influence �±0.005% X span / below V DC Load Capacity < 700 in 24VDC; (mA output) < 1060 in 36VDC (Volt output) Isolation Strength AC1500v 1min between the input / output IP Ranking Casing/Terminal IP50/IP20
High precision temperature transmission Optimized for precision industry Configurable analog signal transmission (4-20mA) Communication via RS485 MODBUS (PC-HMI and PLC) Built-in LCD Simple and sleek design
Features: 1. Real-time monitoring of grain temperature to prevent spoilage 2. 1-wire digital temperature sensors 3. Unique temperature/level (EST120) monitoring cable 4. 98.5ft (30m) maximum cable length 5. Customizable number and location of temperature sensors 6. Simplified and lower installation costs using digital technology, wired or wireless 7. Operator interface with remote monitoring PC-software
Humidity and temperature sensor transmitter Digital frequential ouput Nominal frequency 6.5 khz Std sensitivity 13 hz/%rh Response time 0.3 s Response time with Optional protection : 20 s Accurcy-interchangeability : 3 %hr de 3 a 97%rh Hysttrtsis
- Integrated module with temperature, humidity sensor - Up to 100 nodes can be connected (RS485 models) - Compact design, slim size - Easy installation, offer 3 meter cable - Support the various types of communications protocol