Specifications
Display: 4 digits LCD, backlit
Range: 0~1250 »m/0~50mil
(other ranges can be specified )
Min.radius workpiece: F: Convex 1.5mm/Concave 25mm
N: Convex 3mm/ Concave 50mm
Min. measuring area: 6mm
Min.Sample thickness : 0.3mm
Resolution: 0.1 »m (0~99.9»m);
1 »m (over 100»m)
Accuracy: f+1~3%n or 2.5 »m or 0.1mil
(Whichever is the greater)
Bttery Indicator: Low batter indicator.
PC interface: with RS-232C interface
Power supply: 2x1.5 AAA(UM-4) battery
Operating condition: Temp. 0~50f¦ .
Humidity <95% .
Standard accessories:
Carrying case ...................1 pc.
Operation manual ............ 1 pc.
F probe in built .................1 pc.
NF probe in built...............1 pc.
Calibration foils ..............1set.
Substrate (Iron) ................1 pc.
Substrate (Aluminium)......1 pc.
Optional accessories: RS-232C cable & software:
1.USB adaptor for RS-232C
2.Bluetooth interface
Size: 126x65x35 mm; 5.0x2.6x1.6 inch
Weight: about 81g(not including batteries)
Product synopsis Application:used for measuring thickness and corrosion of pressure vessels,chemical equipment,boilers,oil storage tanks,etc.in industries of petroleum,shipbuilding,power station,and machine manufacturing. Model: CM8829S With separate probe(s) Operating principle: magnetic induction/eddy current (F/NF) Measuring range:0-1250um/0-50mil Resolution: 0.1/1 Accuracy: í+1-3%n or í+2.5um Min. measuring area:6mm Min. sample thickness:0.3mm Battery indicator: low battery indicator Metric/ imperial: convertible Power supply: 4x1.5V AAA(UM-4)battery Auto power off Operating conditions:0-+45íµ(32¿H-104¿H),í_90%RH Dimensions: 126x65x27mm Weight: 81g(not including battery)
Coating thickness meter cm-8823 Application: Product synopsis Measurement range 0200um/500um/1000um/15000um Resolution 0.1/1 Tolerance +(13%n) or +2um Power supply 4x1.5v aa(um-3)battery Dimension 161x69x32
Ultrasonic thickness meter Ultrasonic thickness gauge series Tr-8812 /tr-8811 tr-8810 Measuring range:1.0~225mm /1.2~200mm / 1.2~200mm 0.05~9 inch /0.06~8 inch /0.06~8 inch Sound velocity: 500~9000m/s. Resolution : 0.1mm. Accuracy: +/-(0.5%n+0.1).Operating conditions : 0~400c/10~90%rh. Dimensions: 120*62*30mm /160*68*32mm . Weight: 164g/208g
Applications: *Measture the cast iron thickness,aluminum thickness,quartz glass thickness,PVC thickness,PE thickness,red copper thickness etc. Details: Case Material: Aluminum Alloy Operating Principle: Ultrasonic Measuring Range (metric / Imperial):0.75~400 mm ( 45 # steel, Depend on Probe ) Sound Velocity: 500~9,990 m/s Resolution:0.01 mm / 0.1 mm Accuracy: � (0.5%n + 0.05) For more details,please do not hesitate to contact us.Thank you!
This instrument is compatible with four standards of site to measure surface roughness of various machinery-processed parts, calculate corresponding and clearly display all measurement parameter. When measuring the roughness of a surface, the sensor is placed on the surface and then uniformly slides along the surface by driving the mechanism by the sharp built-in probe. This roughness causes displacement of the probe which results in change of Inductive amount of induction coils so as to generate analogue signal, which is in proportion to the surface roughness at output end of phase-sensitive rectifier. The exclusive dsp processes and calculates and then Outputs the measurement results on lcd. * multiple parameter measurement: ra, rz, rq, rt * highly sophisticated inductance sensor * four wave filtering methods : rc, pc-rc, Gauss and d-p * built-in lithium ion chargeable battery and control Circuit with high capacity * small in size, light in weight and easy to use * can communicate with pc computer for statistics, Print and analyz by the optional cable and the Software for rs232c interface. *manual or automatic shut down. The tester can be Switched off by pressing the power key at any time. On the other hand, the tester will power itself off About 5 minutes after the last key operation.
Moisture meter mc7806 Model: Moisture meter mc7806 Measurement range: moisture content 0-50% Temperature +c10-60f Resolution: 0.1 Accuracy: Moisture: f+(0.5%n+0.1) Temp: f+0.8f Calibration: automatic Power supply: 4x1.5v aa (um-3) battery Dimensions: 182x68x38mm Probe dimension: 170x44x25mm Weight (not including probe):334g Dimensions: 182x68x38mm Probe dimension: 170x44x25mm
Tachometer Eatures: Measuring rpm is safe & accurate without attachment to object. Wide measuring range & high resolution. Digital display gives exact rpm with no guessing or errors. Used the exclusive micro-computer lsi-circuit and crystal time base to offer the high accuracy measurement & fast measuring time. The last value/max. Value/min. Value will be automatically stored in memory and can be displayed by turn. The use of durable, long-lasting components, including a strong, light weight abs-plastic housing assures maintenance free performance for many years. Product synopsis Model: dt Measuring range: rotative velocity laser . - r/min Contact . - r/min Laser tach detecting distance: - mm Accuracy: f+( . %n+ d) Resolution: . / . / Memory: max/min/last value Power supply: x . V aa (um- ) battery Battery indicator: low battery indicator Dimensions: x x mm Weight (not including probe): g
Acceleration 10Hz-1KHz 0.1-400m/ms+ 0.3-1312ft/ms+ 10Hz-10KHz 0.1-400m/ms+ 0.3-1312ft/ms+ Velocity 10Hz-1K 0.1-400mm/s 0.004-16.0inch Displacement 10Hz-1KHz 0.001-4.0mm 0.04-160 mil Accuracy:++5% Auto power off RPM(revolution):5-100000r/min Frequency:0.1 to 10KHz Metric/imperial conversion With RS232C interface Max hold Operating conditions:0-+45f+(32=¬-104=¬),f-90%RH Power supply:4x1.5V AAA(UM-4)battery Battery indicator: low battery indicator Optional accessories: RS-232C cable & software: 1.USB adaptor for RS-232C 2.Bluetooth interface Dimensions : 124x62x30mm Weight: 120g(not including battery)
Application: Used for measuring periodic motion, to check the imbalance and deflecting of moving machinery.Is pecifically designed for present measuring various mechanical vibration. So as to prove the data for the quality control, run time and equipment upkeep. Iuse the high-performance acceleration meter, realize the repetitiveness and accurate measurement.It has the function of testing axle bearing situation. Specifications: Acceleration 0.1-200m2/s (10Hz to 1KHz 10Hz to 10KHz ) Velocity : 0.1-200mm/s0. (10Hz to 1KHz) Displacement: 0.001-2.0mm(10Hz to 1KHz) Accuracy:·+5¼t Auto power off Max hold Operating conditions:0-+40f¦(32+H-104+H),f_90%RH Power supply: 4x1.5V AA(UM-3)battery Battery indicator: low battery indicator Dimensions : 160x68x32mm Weight: 181g(not including battery)