Specifications Display: 4 digits LCD, backlit Range: 0~1250 ¬ªm/0~50mil (other ranges can be specified ) Min.radius workpiece: F: Convex 1.5mm/Concave 25mm N: Convex 3mm/ Concave 50mm Min. measuring area: 6mm Min.Sample thickness : 0.3mm Resolution: 0.1 ¬ªm (0~99.9¬ªm); 1 ¬ªm (over 100¬ªm) Accuracy: f+1~3%n or 2.5 ¬ªm or 0.1mil (Whichever is the greater) Bttery Indicator: Low batter indicator. PC interface: with RS-232C interface Power supply: 2x1.5 AAA(UM-4) battery Operating condition: Temp. 0~50f¦ . Humidity
Acceleration 10Hz-1KHz 0.1-400m/ms+ 0.3-1312ft/ms+ 10Hz-10KHz 0.1-400m/ms+ 0.3-1312ft/ms+ Velocity 10Hz-1K 0.1-400mm/s 0.004-16.0inch Displacement 10Hz-1KHz 0.001-4.0mm 0.04-160 mil Accuracy:++5% Auto power off RPM(revolution):5-100000r/min Frequency:0.1 to 10KHz Metric/imperial conversion With RS232C interface Max hold Operating conditions:0-+45f+(32=¬-104=¬),f-90%RH Power supply:4x1.5V AAA(UM-4)battery Battery indicator: low battery indicator Optional accessories: RS-232C cable & software: 1.USB adaptor for RS-232C 2.Bluetooth interface Dimensions : 124x62x30mm Weight: 120g(not including battery)
Application: Used for measuring periodic motion, to check the imbalance and deflecting of moving machinery.Is pecifically designed for present measuring various mechanical vibration. So as to prove the data for the quality control, run time and equipment upkeep. Iuse the high-performance acceleration meter, realize the repetitiveness and accurate measurement.It has the function of testing axle bearing situation. Specifications: Acceleration 0.1-200m2/s (10Hz to 1KHz 10Hz to 10KHz ) Velocity : 0.1-200mm/s0. (10Hz to 1KHz) Displacement: 0.001-2.0mm(10Hz to 1KHz) Accuracy:·+5¼t Auto power off Max hold Operating conditions:0-+40f¦(32+H-104+H),f_90%RH Power supply: 4x1.5V AA(UM-3)battery Battery indicator: low battery indicator Dimensions : 160x68x32mm Weight: 181g(not including battery)
Features Used in production site to measure surface roughness of various machinery-processed parts, calculate corresponding parameters according to selected measuring conditions and clearly display all measurement parameters. Specifications Displayª 4 digits, 10 mm LCD, with blue backlight Parameters: Ra, Rz Display Range Ra: 0.05-10.00um/1.000-400.0uinch Rz: 0.020-100.0um/0.780-4000uinch Accuracy: Not more than 10% Fluctuation of display value: Not more than 6% Sensor : Test Principle: Inductance type Radius of Probe Pin: 10um Material of Probe Pin: Diamond Measurement Force of Probe: 16mN(1.6gf) Probe Angle: 90fp Vertical Radius of Guiding Head: 48mm Maximum driving stroke: 17.5mm/0.7inch Cutoff length (l): 0.25mm / 0.8mm / 2.5mm optional Evaluation length: 1~5 cut off optional Driving speed: sampling length = 0.25mm Vt=0.135mm/s sampling length = 0.8mm Vt=0.5mm/s sampling length = 2.5mm Vt=1mm/s returning Vt=1mm/s Resolution : 0.001¬ªm if reading ·+10¬ªm 0.01¬ªm if 10¬ªmf_reading·+100¬ªm 0.1¬ªm if reading fª100¬ªm Power Li-ion battery: rechargeable Operating conditions: Temp. 0-50f¦ Humidity
Features This instrument is compatible with four standards of site to measure surface roughness of various machinery-processed parts, calculate corresponding and clearly display all measurement parameters. When measuring the roughness of a surface, the sensor is placed on the surface and then uniformly slides along the surface by driving the mechanism by the sharp built-in probe. This roughness causes displacement of the probe which results in change of inductive amount of induction coils so as to generate Specifications Display·ª 4 digits, 10 mm LCD, with blue backlight Parameters: Ra, Rz, Rq, Rt Measuring Range Ra, Rq: 0.005-16.00um/0.020-629.9uinch Rz,Rt: 0.020-160.0um/0.078-6299uinch Accuracy: f_f+10% Fluctuation of display value: Not more than 6% Sensor : Test Principle: Inductance type Radius of Probe Pin: 5um Material of Probe Pin: Diamond Dynamo-measurement of Probe: 4mN(0.4gf) Probe Angle: 90fp Vertical Radius of Guiding Head: 48mm Maximum driving stroke: 17.5mm/0.7inch Cutoff length (l): 0.25mm / 0.8mm / 2.5mm optional Evaluation length: 5l Driving speed: sampling length = 0.25mm Vt=0.135mm/s sampling length = 0.8mm Vt=0.5mm/s sampling length = 2.5mm Vt=1mm/s returning Vt=1mm/s Profile digital filter Filtered Profile: RC Filtered Profile: PC-RC Filtered Profile: Gauss Non-Filtered Profile: D-P Resolution : .001¬ªm if reading ·+10¬ªm 0.01¬ªm if 10¬ªmf_reading·+100¬ªm 0.1¬ªm if reading fª100¬ªm Evaluation length : 5 cut-off Power Li-ion battery: rechargeable Operating conditions: Temp. 0~50f¦ Humidity
Ultrasonic thickness meter Ultrasonic thickness gauge series Tr-8812 /tr-8811 tr-8810 Measuring range:1.0~225mm /1.2~200mm / 1.2~200mm 0.05~9 inch /0.06~8 inch /0.06~8 inch Sound velocity: 500~9000m/s. Resolution : 0.1mm. Accuracy: +/-(0.5%n+0.1).Operating conditions : 0~400c/10~90%rh. Dimensions: 120*62*30mm /160*68*32mm . Weight: 164g/208g
Product synopsis Application:used for measuring thickness and corrosion of pressure vessels,chemical equipment,boilers,oil storage tanks,etc.in industries of petroleum,shipbuilding,power station,and machine manufacturing. Model: CM8829S With separate probe(s) Operating principle: magnetic induction/eddy current (F/NF) Measuring range:0-1250um/0-50mil Resolution: 0.1/1 Accuracy: í+1-3%n or í+2.5um Min. measuring area:6mm Min. sample thickness:0.3mm Battery indicator: low battery indicator Metric/ imperial: convertible Power supply: 4x1.5V AAA(UM-4)battery Auto power off Operating conditions:0-+45íµ(32¿H-104¿H),í_90%RH Dimensions: 126x65x27mm Weight: 81g(not including battery)
flow meter
Coating thickness meter cm-8823 Application: Product synopsis Measurement range 0200um/500um/1000um/15000um Resolution 0.1/1 Tolerance +(13%n) or +2um Power supply 4x1.5v aa(um-3)battery Dimension 161x69x32