Technical Parameter
Rated Voltage
& Frequency 400VAC; 3 phase 4 wire, 50/60Hz
Max Load Power 510kW at 400V
Load Steps Resistive Load: 1, 2, 2, 5, 10, 20, 20, 50, 100, 100, 200kW
Power Factor 1
Load Tolerance (each step) 5%
Load Tolerance (overall) 3%
Display Meter Multiple function meter
Fan Control Power External power 380VAC 3 phase 4 wire 50Hz
Wire Connection Load bank input busbar (star coupling )
Control power input terminal block
Communication Interface RS232/RS485
Insulation F
Way of Working Continuous Working
Cooling Forced air, horizontal air intake and exhaust cooling, there will be louver at air outlet and inlet
Transportation With lifting eyes and wheel castors
Color Gray RAL7035 or yellow
Dimensions 1800*1300*1070mm LWH
Weight 700kgs
Operating Environment Parameter
Ambient Temperature 20C50C
Using Place Outdoor
Altitude 2500 meters
Relative Humidity 95%
Atmospheric Pressure 86 106kPa
Brands of Main Components
Contactor
Fuse MIRO
PLC Siemens
Alloy Resistor
Data Processing Software
Load Bank parameter: Rated Voltage & Frequency: 400VAC; 3 phase 4 wire, 50/60Hz, single phase 230V Max Load Power: 200kW Load Resolution: 1, 2, 2, 5, 10, 20, 40, 40, 80kW Power Factor: 1 Load Tolerance (overall): 3% Fan Control Power: AC110-240V single phase 50/60Hz Wire Connection: Load bank input terminal block Control power input 3-pin plug Communication Interface: RS485 Insulation: F Way of Working: Continuous Working Cooling Forced air, horizontal exhausting or vertical exhausting Transportation: With handle Dimensions Horizontal exhausting: 748*509*661mm (LH) Vertical exhausting: 663*512*746mm (LH) Weight: About 70kgs Operating Environment Parameter Ambient Temperature 20 50 Relative Humidity: 95% Atmospheric Pressure: 86 106kPa Brands of Main Components PLC: Siemens Alloy Resistor: Kaixiang Data Processing Software: Kaixiang
* Wide voltage range battery discharger: 12V to 280V * 5.7 inch LCD touch screen for easy operation and showing various parameters real time * Selectable discharge mode: constant current/power / resistance * 4 adjustable stop points and multiple alarm designs to control the discharge process intelligently * Support RS232 real time monitoring by PC or USB download data after discharge * PC software for capacity evaluation and report generation * Optional wireless modules for 1.2V/2V/6V/12V cells voltage real-time measuring. Overview: Although battery resistance testing methods are improving and very popular, battery discharge test still is the most accurate and reliable method for actual capacity evaluation of battery groups. Because only constant current discharge can perfectly simulate the working status under loading for batteries, power supply departments in many companies and utilities keep the periodic discharge testing in their maintenance management. Because the DC power systems in various industrial utilities are using different voltage level battery groups (24V, 48V, 110V, 120V, 220V, 240V etc.), and most of professional users hope to find an unattended and automatic instrument to simplify discharge process, the battery discharge tester with intelligent designs and super voltage variability for almost all battery types would be preferable. Features: Wide Range 840CT can support 10-300V battery groups, the application of 840CT includes: Battery Nominal Voltage: Max Discharge Current 240 V / 220 V: 60 A 120 V / 110 V: 120 A 96 V: 120 A 48 V: 120 A 24 V: 120 A 12 V: 60 A Multiple Adjustable Stop Points 840CT offers 4 adjustable points for test stop points to avoid excessive discharge: Stop Point: Setting Range Group Low Voltage: 0-250.0 V Discharge Time: 0-99 Hour 99 Min Discharge Capacity: 0-9999 AH Cell Low Voltage: 0-15.00 V. 840CT also offer selectable quantity of cells which voltages below the stop point, this design could help you to locate more lag batteries in once constant discharging. Selectable Discharge Modes 840CT provides 3 discharge modes for different test requirement: Discharge Mode: Range Constant Current: 0-120 A Constant Power: 0-14 Kw Constant resistance: 0.16 5.7 inch Touch LCD Display Super big size touch LCD can display all real time data and graphs and support the click operations directly, humanized input method and menu designs simplified operating process. Presetting Function: The presetting function for discharge parameters provide 8 locations for setting up all discharge parameters in advance, this design can skip the setting procedures for the same discharging, simplified the operation and speed up the test. Internal Memory: * 840CT can save several independent discharge records automatically without Laptop monitoring, non-volatile internal memory guarantee the data security even in unexpected shutdown. * The menu interface provides some management operations like reviewing, deleting, downloading to PC by USB disk or RS232. Optional wireless cells voltage monitoring * Wireless modules for cells voltage measuring are available for 1.2V/2V/6V/12V batteries voltage monitoring during discharge test. * Each wireless module can monitor 4 batteries simultaneously. Comparing with the traditional cable voltage measuring method that each module only can monitor 1 battery, the new wiring operation is much easier. * With proper number wireless modules, main tester can real time scan and display the voltage data of each battery during the discharging, and display the histogram of all batteries to follow the battery voltage tracks in whole discharging process. * Intelligent judge program: 840CT can identify the situations that the battery voltages reach the threshold value or the signal missing by manual mistake. Avoiding manual interruption in the discharging, this revolutionary program makes the test stable and smooth. * 840CT also supports cable modules for special requirements. Multiple Protections & Alarms: Malfunctions: LCD prompt: beep warning Input over-voltage Reverse polarity Overload Overheat 840CT provides ample protective measures for various abnormal situations during discharge. Automatic termination, LCD prompt and beep warning would assist users to make proper treatments. Extendable & Compatible: Connecting with clamp current, 840CT cooperate other types in -CT series or any other load units, and clamp current can count external current in. PC ANALYSIS SOFTWARE: * Support data downloading and analyzing through real time communication or USB memory devices * The software interface includes: battery voltages curve and bar chart, battery resistances bar chart, group voltage curve, current curve, capacities histogram, data form and so on. * Powerful capacity estimating function, the software can predict the capacity of each battery in the tested group. * The software shows the data by various ways like bar charts, curve, and form. And users can magnify or minify any windows to read more details. * Automatically create EXCEL data report, it¡¯s so convenient to send or download the data. SPECIFICATIONS: Discharge Ranges Voltage range: current range 10-15V: 0-60A 15V-60V: 0-120A 86-150V: 0-120A 190-280V: 0-60A Current measurement: Internal current range: 0-120A Accuracy &resolution: 0.5%, 0.1 A External current range: 0-600A(optional current clamp) Accuracy &resolution: 1%, 0.1 A Voltage measurement Group voltage range: 0-300 V Accuracy &resolution: 0.5%, 0.1 V Cell voltage range: 0-15V Accuracy &resolution: 0.5%, 0.01 V Power Supply Power supply voltage: 220 V AC (-20% to +30%) Frequency: 50/60 Hz Power consumption:: 350W(max) Communication & Storage Communicate port: USB/RS232 Internal memory: 8Mbit Flash CE Certificate: LVD standards : 2006/95/EC:EN 61010-1:200 EMC standards: 2004/108/EC Annex II: EN 61000-6-1:2007 EN 61000-6-3:2007 EN 61000-3-2:2006+A2:2009 EN 61000-3-3:2008 Environment: Operation temperature: -5 to 50o C Storage temperature: -40 to 70o C Humidity: 5% - 95% RH Altitude: below 4000 m Working noise:
Diesel generator Specifications 1. Powered by reliable engines 2. Branded alternator 3. Open type, silent type or super silent type generator 4. ISO, CE certified Generator specs: Rated output: 2 to 2,000kW/2 to 2,500kVA Rated voltage: L-N 110 to 277V, L-L 220 to 480V Rated frequency: 50/60Hz Engine: Brands: Cummins, Perkins, Lovol, Deutz, Doosan, Mitsubishi, Kubota, Yanmar or other reliable Chinese engines such as Fawde and Laidong. Cooling method: closed water-cooled or air-cooled Starting method: electric start or recoil start Noise level: 56 to 75dB, 7 meters away Alternator: Brands: Stamford, Leroy Somer, Mecc Alte and Keypower brushless alternator Rated output: 8 to 2,000kW/10 to 2,500kVA Rated voltage: L-N 110 to 277V, L-L 220 to 480V Rated frequency: 50/60Hz Phase: 3-phase, 4-wire or 1-phase, 2-wire Connection: y or other type connection Rated speed: 1,500/1,800rpm Excitation: harmonic excitation or phase compound or brushless Voltage regulation: AVR automatic 1.0% voltage regulation in static conditions (maximum) Protection class: IP23 Control panel: Deepsea, ComAp, Keypower PE film with hard paper corner protector
Supplier: Winding components eg. servo controlled voltage stabilizer, transformer, dimmer, choke, cvt, battery charger,ups inductive load banks,dc rectifier
Supplier: Perkins Spare Parts, Perkins Diesel Generator Supplier, Construction Equipment, Industrial Equipment , Dewatering Pumps, Generator Load Bank Testing
Supplier: Generator, load bank, ATS
Supplier: Spare Parts For Generators, Load Banks, Compressors And Other Industrial Machines
Buyer: Solid State Regulator 440/660 Vac
Sikes offers a complete line of industrial control transformers, which provide stepped-down voltages to machine tool control devices. It¡¡¥s specifically designed to meet high inrush industrial applications where electromagnetic components such as relay, solenoids and magnetic motor starters are used. Technical parameters Insulation class: h Environment exists without gas, steam, chemical deposition, dust or dirt that will affect transformer¡¡¥s insulation seriously, explosive or corrosive medium is not allowed. Standard: iec726:1982 dry power transformer , gb6450-86(equivalent to iec726:1982) Standard carton or wooden case based on the custom made product.
Isolation transformer is used for low-voltage distribution system, isolate load from power, reject stray common mode and dc voltages, ground loop potentials, electromagnetic interference (emi) and radio frequency interference (rfi) from Dielectric strength: l-l, l-g 4000vac/50hz/60s. Free of arcing breakage I se is less than 65db (to be measured at the point 1 meter away from the reactor horizontally) . Protection class: ip00 or as customer required. Insulation class: h Environment exists without gas, steam, chemical deposition, dust or dirt that will affect transformer¡¡¥s insulation seriously, explosive or corrosive medium is not allowed. Standard: iec726:1982 dry power transformer , gb6450-86(equivalent to iec726:1982) Standard carton or wooden case to the custom made transformer