Isolation transformer is used for low-voltage distribution system, isolate load from power, reject stray common mode and dc voltages, ground loop potentials, electromagnetic interference (emi) and radio frequency interference (rfi) from
Dielectric strength: l-l, l-g 4000vac/50hz/60s. Free of arcing breakage
I se is less than 65db (to be measured at the point 1 meter away from the reactor horizontally) .
Protection class: ip00 or as customer required.
Insulation class: h
Environment exists without gas, steam, chemical deposition, dust or dirt that will affect transformer¡¡¥s insulation seriously, explosive or corrosive medium is not allowed.
Standard: iec726:1982 dry power transformer , gb6450-86(equivalent to iec726:1982)
Standard carton or wooden case to the custom made transformer
SGB (DGB) series three-phase (single-phase) dry-type, isolating, voltage transformer is a multi-coil (double coil and above) structure voltage transformer, the primary and secondary windings are insulated from each other. Its transformation ratios are of fixed and tapping type, which enable voltage bucking and boosting. It can also electrically isolate input and output windings from each other to avoid risks of simultaneous access to electrified body (or electrified metal parts due to insulation damage) and ground hazard. Besides, it also has certain inhibiting effect of various kinds of interference.
2450Kva threee phase dry type transformer Our products got certificate of ISO9001,ISO14001 and OHSAS18001. And 18 low voltage products get national certificate of CCC. Also our products get quality testing report from China Quality Certification Center(CQC). Our customers include urban distribution network, power station, transformer substation, oil, chemical, railway and big construction companies. And products export to America, Brazil, Peru, Kenya, Ethiopia, India, Myanmar, Vietnam etc. We sincerely welcome all friends from domestic and overseas to come to cooperate and develop together.
Dry-type transformer.Power range is:100-20000-30000 kVA. Durable to instantenous temperature changes and also to short-circuit. 100% protected from moisture.It cant get fired has an ability to extinguish the fire. Does not contain any Halogen or Nitrogen.Price changes due to power range.
Introduce: This product has advantages of low no-load losses, oil-free, flame self-extinguishing, moisture, crack-resistant and maintenance free. Now the entire place which used the ordinary dry type transformer can be replaced by amorphous one. It can be used for high-rise buildings, commercial centers, subways, airports, railway stations, factories and power plants, especially suitable for flammable, explosive high-demand places. Performance: - low-energy saving - high corrosion resistance - strong ability to withstand short circuit - low noise - low temperature and long service life Application area: - altitudeâ?¤1000m - environmental temperature -25+40 - indoor use
Our dry-type transformers, also known as "dry transformers," are designed to provide efficient and reliable electrical power distribution. These transformers use air or resin as the cooling medium instead of traditional oil. This design minimizes the risk of environmental contamination and allows for safe operation in various settings. Key features of our dry-type transformers include: 1. **Safety and Environmental Friendliness:** As there is no oil involved, the risk of fire and environmental impact is significantly reduced. This makes them a safer and more environmentally friendly option. 2. **Versatility:** Dry-type transformers are suitable for a wide range of applications, including industrial facilities, commercial buildings, and residential areas. They can be customized to meet specific voltage and power requirements. 3. **Low Maintenance:** These transformers generally require lower maintenance compared to oil-filled transformers, resulting in cost savings over their lifecycle. 4. **Compact Design:** The absence of oil allows for a more compact and lightweight design, making them easier to install and suitable for locations with space constraints. 5. **Efficiency:** Our dry-type transformers are designed for high efficiency, ensuring minimal energy loss during power distribution. Whether for upgrading existing infrastructure or implementing new projects, our dry-type transformers are engineered to deliver optimal performance, reliability, and safety in diverse electrical applications.
SC(B)10 Series Resin-insulated Dry Type Transformer,cast resin transformer,dry-type transformerï¼?cast resin dry transformerï¼?step up dry transformer Dry Type Transformer Flame retardant, non-pollution, it can be installed directly in the load center. Maintenance-free, easy to be installed, low operating costs. Product Features Function Characteristics: Flame retardant, non-pollution, it can be installed directly in the load center. Maintenance-free, easy to be installed, low operating costs. The enclosure can be of Good moisture resistance, transformer can be put into operation without pre-drying under 100% humidity in the normal operation. Low loss, light weight and small volume, low noise, good dissipation of heat, it can be 150% rated load operation under forced air cooling conditions. Equipped with a complete temperature protection control system to provide reliable protection for the safe operation of transformers. High reliability. The results of checking for the products that has been put into operation show that the reliability index has reached the international advanced level. Structural Characteristics: Foil Coil: Adopting the entire section of copper foil, together with the F-class turn insulation, low voltage winding is wound by the special low-voltage foil winding machine. The foil coil resolves problems such as large short-circuit stress, ampere turn unbalance, poor heat dissipation, existing the winding spiral angle and unsteady manual welding quality due to low voltage and large current coil. At the same time, the end of winding is treated with cast resin, solidification to make shape, moisture-proof and anti-fouling, the lead for copper bar is welded by argon arc welding automatically. Temperature Control Device: the transformer adopts BWDK series of signal thermometer. The temperature components are embedded in the upper half of the low-voltage coil, can detect and display the temperature of separate phase coil automatically and continuously, also have the functions of over-temperature alarm and trip. We are pleased to deliver Transformer, Distribution Transformer, Power Transformer, Oil Transformer, Dry Type Transformer. Safe payment and on time deliver time will give you.If you want to know more about the product, please click here.
Three-phase transformers are used to convert the available 3-phase mains voltage into any load voltage. To cater for the wide range of application areas involved,these transformers are essentially available in the same kinds of designs as the single-phase transformers, e.g. Three-phase dry-type transformer: separate winding version Three-phase series transformer: autotransformer winding version Three-phase safety, isolating, mains or insulating transformer: separate winding version In terms of how the 3 coils are connected, there are various options available and each of these provides the transformers with specific properties. The vector group code is composed of the following elements: The upper-case letter indicates the higher-voltage winding (the highest voltage in terms of operation). The lower-case letter indicates the lower-voltage winding. The brought-out neutral is indicated by means of N or n (depending on voltage level). â?¢ The distinctive number indicates the phase angle of the lower voltage in relation to the higher voltage (distinctive number multiplied by 30). The following winding connection options are available Delta: D, d Wye (or star): Y, y Zigzag: Z, z Example: Dyn5 Higher-voltage winding is delta-connected. Lower-voltage winding is star-connected with a brought-out neutral. The lower voltage lags behind the higher voltage by 150�° (5 x 30�°). Unless specifically requested otherwise, the transformers are configured with a double-star connection and a brought-out neutral (vector group Yyn0); for autotransformers the vector group is YNa0. Our three-phase transformer range includes all our standardised types for the 25 30.0 kVA performance range and a frequency of 50/60 Hz
1.Dry transformers with high and low voltage windings are coated by a thin layer of epoxy resin.It has the advantages of flame retardant, self-extinguishing, moisture-proof, heat dissipation and so on. 2.Equipped with a low-noise air-cooled device, the fan can be automatically controlled to start and close through the thermostat, so that the transformer can be operated with a 40% increase in capacity. 3.It can go deep into load centers, such as high-rise buildings, airports, wharfs, power plants, residential communities or complete sets of substations. 4.The temperature sensing element and the sensing system embedded in the low voltage winding can start and turn off the fan or alarm or trip according to the set value for protection.
Brief Description The insulation non-encapsulated dry-type power transformer is approved by America technology. With the advantages of safety, reliability, environmental friendliness, energy saving, fire and explosion protection, humidity and pollution resistance, strong overload capability, small volume and simple maintenance, and main performance indexes superior to domestic standards such as advanced design, reasonable structure and beautiful appearance, the product is a brand new transformer value-added scheme and is a new-generation energy-saving, safe, green and environmentally-friendly high-tech product!