Technical Parameter
Rated Voltage
& Frequency 400VAC; 3 phase 4 wire, 50/60Hz
Max Load Power 510kW at 400V
Load Steps Resistive Load: 1, 2, 2, 5, 10, 20, 20, 50, 100, 100, 200kW
Power Factor 1
Load Tolerance (each step) 5%
Load Tolerance (overall) 3%
Display Meter Multiple function meter
Fan Control Power External power 380VAC 3 phase 4 wire 50Hz
Wire Connection Load bank input busbar (star coupling )
Control power input terminal block
Communication Interface RS232/RS485
Insulation F
Way of Working Continuous Working
Cooling Forced air, horizontal air intake and exhaust cooling, there will be louver at air outlet and inlet
Transportation With lifting eyes and wheel castors
Color Gray RAL7035 or yellow
Dimensions 1800*1300*1070mm LWH
Weight 700kgs
Operating Environment Parameter
Ambient Temperature 20C50C
Using Place Outdoor
Altitude 2500 meters
Relative Humidity 95%
Atmospheric Pressure 86 106kPa
Brands of Main Components
Contactor
Fuse MIRO
PLC Siemens
Alloy Resistor
Data Processing Software
Load Bank parameter:
Rated Voltage & Frequency: 400VAC; 3 phase 4 wire, 50/60Hz, single phase 230V
Max Load Power: 200kW
Load Resolution: 1, 2, 2, 5, 10, 20, 40, 40, 80kW
Power Factor: 1
Load Tolerance (overall): 3%
Fan Control Power: AC110-240V single phase 50/60Hz
Wire Connection: Load bank input terminal block
Control power input 3-pin plug
Communication Interface: RS485
Insulation: F
Way of Working: Continuous Working
Cooling Forced air, horizontal exhausting or vertical exhausting
Transportation: With handle
Dimensions Horizontal exhausting: 748*509*661mm (LH)
Vertical exhausting: 663*512*746mm (LH)
Weight: About 70kgs
Operating Environment Parameter
Ambient Temperature 20 50
Relative Humidity: 95%
Atmospheric Pressure: 86 106kPa
Brands of Main Components
PLC: Siemens
Alloy Resistor: Kaixiang
Data Processing Software: Kaixiang