Load Bank parameter:
Rated Voltage & Frequency: 400VAC; 3 phase 4 wire, 50/60Hz, single phase 230V
Max Load Power: 200kW
Load Resolution: 1, 2, 2, 5, 10, 20, 40, 40, 80kW
Power Factor: 1
Load Tolerance (overall): 3%
Fan Control Power: AC110-240V single phase 50/60Hz
Wire Connection: Load bank input terminal block
Control power input 3-pin plug
Communication Interface: RS485
Insulation: F
Way of Working: Continuous Working
Cooling Forced air, horizontal exhausting or vertical exhausting
Transportation: With handle
Dimensions Horizontal exhausting: 748*509*661mm (LH)
Vertical exhausting: 663*512*746mm (LH)
Weight: About 70kgs
Operating Environment Parameter
Ambient Temperature 20 50
Relative Humidity: 95%
Atmospheric Pressure: 86 106kPa
Brands of Main Components
PLC: Siemens
Alloy Resistor: Kaixiang
Data Processing Software: Kaixiang
Technical Parameter Rated Voltage & Frequency 400VAC; 3 phase 4 wire, 50/60Hz Max Load Power 510kW at 400V Load Steps Resistive Load: 1, 2, 2, 5, 10, 20, 20, 50, 100, 100, 200kW Power Factor 1 Load Tolerance (each step) 5% Load Tolerance (overall) 3% Display Meter Multiple function meter Fan Control Power External power 380VAC 3 phase 4 wire 50Hz Wire Connection Load bank input busbar (star coupling ) Control power input terminal block Communication Interface RS232/RS485 Insulation F Way of Working Continuous Working Cooling Forced air, horizontal air intake and exhaust cooling, there will be louver at air outlet and inlet Transportation With lifting eyes and wheel castors Color Gray RAL7035 or yellow Dimensions 1800*1300*1070mm LWH Weight 700kgs Operating Environment Parameter Ambient Temperature 20C50C Using Place Outdoor Altitude 2500 meters Relative Humidity 95% Atmospheric Pressure 86 106kPa Brands of Main Components Contactor Fuse MIRO PLC Siemens Alloy Resistor Data Processing Software
Diesel generator Specifications 1. Powered by reliable engines 2. Branded alternator 3. Open type, silent type or super silent type generator 4. ISO, CE certified Generator specs: Rated output: 2 to 2,000kW/2 to 2,500kVA Rated voltage: L-N 110 to 277V, L-L 220 to 480V Rated frequency: 50/60Hz Engine: Brands: Cummins, Perkins, Lovol, Deutz, Doosan, Mitsubishi, Kubota, Yanmar or other reliable Chinese engines such as Fawde and Laidong. Cooling method: closed water-cooled or air-cooled Starting method: electric start or recoil start Noise level: 56 to 75dB, 7 meters away Alternator: Brands: Stamford, Leroy Somer, Mecc Alte and Keypower brushless alternator Rated output: 8 to 2,000kW/10 to 2,500kVA Rated voltage: L-N 110 to 277V, L-L 220 to 480V Rated frequency: 50/60Hz Phase: 3-phase, 4-wire or 1-phase, 2-wire Connection: y or other type connection Rated speed: 1,500/1,800rpm Excitation: harmonic excitation or phase compound or brushless Voltage regulation: AVR automatic 1.0% voltage regulation in static conditions (maximum) Protection class: IP23 Control panel: Deepsea, ComAp, Keypower PE film with hard paper corner protector
Supplier: Winding components eg. servo controlled voltage stabilizer, transformer, dimmer, choke, cvt, battery charger,ups inductive load banks,dc rectifier
Supplier: Generator, load bank, ATS
Sikes offers a complete line of industrial control transformers, which provide stepped-down voltages to machine tool control devices. It¡¡¥s specifically designed to meet high inrush industrial applications where electromagnetic components such as relay, solenoids and magnetic motor starters are used. Technical parameters Insulation class: h Environment exists without gas, steam, chemical deposition, dust or dirt that will affect transformer¡¡¥s insulation seriously, explosive or corrosive medium is not allowed. Standard: iec726:1982 dry power transformer , gb6450-86(equivalent to iec726:1982) Standard carton or wooden case based on the custom made product.
Isolation transformer is used for low-voltage distribution system, isolate load from power, reject stray common mode and dc voltages, ground loop potentials, electromagnetic interference (emi) and radio frequency interference (rfi) from Dielectric strength: l-l, l-g 4000vac/50hz/60s. Free of arcing breakage I se is less than 65db (to be measured at the point 1 meter away from the reactor horizontally) . Protection class: ip00 or as customer required. Insulation class: h Environment exists without gas, steam, chemical deposition, dust or dirt that will affect transformer¡¡¥s insulation seriously, explosive or corrosive medium is not allowed. Standard: iec726:1982 dry power transformer , gb6450-86(equivalent to iec726:1982) Standard carton or wooden case to the custom made transformer
Supplier: Transformer, inductance reactor, active front end, power resistor, load bank, EMI, EMC filter, dynamic braking unit
Supplier: Intelligent battery charge, discharge tester, intelligent battery activation instrument, automatic charge, discharge dual set, single cell test & discharge set, battery charger, marine AC load bank, automatic AC load bank
Supplier: Backup Power Supply Emergency Power Supply DC Battery Load Tester AC Resistive Load Bank Solar Controller Inverter Battery Impedance Tester Battery Conductance Tester UPS Uninterruptible Power Supply Battery Jump Starter Battery Regenerator Lead Acid Battery Charger Battery Charge Discharge Tester Wide Range Battery Load Bank Tester DC Ground Fault Locator