NCS Series of Intelligent Transmitters are digital, intelligent, network-based, merged with advanced, reliable and stable sensor technology, to be designed as a new generation of Fieldbus Intelligent Transmitter.
NCS Series of Intelligent Transmitter have been designed with high precision and high reliability, high stability. The pressure, temperature, currents and other physical quantities are displayed on LCD module. Zero drift, range settings and many other functions, are realized by the magnetism bar operation. The interoperability between different systems and equipments are realized by the Equipment Description Document, which is compatible to a variety of device management software, and adapting to harsh electromagnetic environment. NCS Series of Intelligent Transmitter have been used in inflammable and explosive places according to Intrinsically Safety Design.
The Fieldbus Technology is used in NCS-TT105 Intelligent Temperature Transmitter, which is a new generation of Fieldbus Intelligent Temperature Transmitter, also an indispensable field device in control processing. It is integrated with a variety of functional modules, to realize not only the general testing functions, also the complicated control strategy.
Digital technology is applied in NCS-TT105, which has been used in a wide range of thermal resistance and thermocouple sensors. It has a wide measuring range. Because of the simple interface between the field and control room, the costs of installation, operation and maintenance are reduced a lot.
NCS-TT105 Series of Intelligent Temperature Transmitters, complied with FF Protocol, have been widely used in petroleum, chemical, metallurgy, electricity, cement,etc.
Thermo resistance additional parameters as follows:
Parameter
Function Description
COMP_WIRE1
Linearization compensation for thermo resistance 1 selecting 2-wire or 3-wire.
Unit is fixed as Ω.
COMP_WIRE2
Linearization compensation for thermo resistance 2 selecting 2-wire or 3-wire.
Unit is fixed as Ω.
SENSOR_CONNECTION
It can be used to connect sensor with 2-wire or 3-wire.
0: 2-wire
1: 3-wire
Dp-100 1.Specification: ¨®installing size: Panel size:64¨¢31mm Hole-opening size: 58.4¨¢25.7mm ¨® operating environment: Environment temperature range:0, 60 Environment humidity range:20%, 85%(no condensate) ¨® main function parameters: Temperature measuring and displaying range¡êo-40, 110 Display resolution¡êo¡ê¼100 0.1; y100 1 Accuracy¡êo¨¤1 Display eee when sensor error(short or open circuit) Power supply¡êo220vac¨¤10%¡ê¬50/60hz Power consumption¡êo, 3w Sensor:ntc Safety level of the front panel:ip54 Operating temperature¡êo0, 60 Storage temperature¡êo-30, 75 Relative humidity¡êo20, 85¡ê£¤¡ê¡§no condensate¡ê© 2.Features: ¨® led displays measuring temp.Values, clear, direct and not affected by the ray. ¨® inlaid panel, 220vac power supply, easy to install. ¨® wide temp, measuring range and high accuracy.
- Material : Stainless Steel Core, Polyethylene Yarn, Span Yarn - Number of Stitiches : 10 Gauge - Length : 14 inch - Cut Level : 5 - Color : Gray, Black, White - Packing : 1pair/individual packing (1pack=5pair, 1box=200pair) - Origin : Made in South Korea - Purpose : Cut Resistant
High precision temperature transmission Optimized for precision industry Configurable analog signal transmission (4-20mA) Communication via RS485 MODBUS (PC-HMI and PLC) Built-in LCD Simple and sleek design
Type Universal USB charger socket Charging Port 2 Ports Connection Universal USB charger socket Warranty 1 Year Combination Charger Socket Outlet Voltage 12-24v Model Number DS2014 Design Style New China-Chic Product name 4.2A Car Cigarette Lighter Socket Splitter Dual USB Charger Material ABS Input Voltage 12V-24V USB output 4.2A Size 3.7*5.4*2.9cm/1.5*2.12*1.14inch LED Blue LED Waterproof grade IP65 Working temperature Min.-20 Celsius Degree, Max. 80 Celsius Degree
Features: 1. Real-time monitoring of grain temperature to prevent spoilage 2. 1-wire digital temperature sensors 3. Unique temperature/level (EST120) monitoring cable 4. 98.5ft (30m) maximum cable length 5. Customizable number and location of temperature sensors 6. Simplified and lower installation costs using digital technology, wired or wireless 7. Operator interface with remote monitoring PC-software
MS182 is a smart in-head transmitter module with HART® -protocol. It has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection, and converts various input signals into a standard 4 to 20 mA analog output signal after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use PC or the hand operator Measuring range Set via PC or by the hand operator Input type RTD, TC, R or Millivolt signal Convert accuracy 0.1£¥FS Cold junction accuracy ¡À1(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output HART ¨CProtocol output Max-load £¨V -13V£©/0.025A£¨Current output £© Limit current 25mA Response time 1s Isolated voltage 1500V AC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: 3.6mA or ¡Ý21.0mA Power supply 13¡«30V DC Temperature drift 0.01£¥ FS/1 Long-term stability 0.1 per year or 0.05 £¥per year Ambient -40¡«+85.
MS181 is an intelligent temperature transmitter module which can be programmed through a PC with Configuration Kit. It has measurement input for resistance thermometers (RTD) ,thermocouples, resistances or millivolt signals in 2-,3- or 4-wire connection, and converts various input signals into a 4~ 20mA analog output signal after linear processing. Isolation is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use the MS181 programming tool Measuring range Set via PC PC Interface USB/RS232 Input type RTD, TC, R or Millivolt signal Convert accuracy ¡Ü0.1£¥FS Cold junction accuracy ¡À1(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output Max-load £¨V -8V£©/0.025A£¨Current output £© Limit current ¡Ü25mA Response time 1s Isolated voltage 1500V AC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: ¡Ü3.6mA or¡Ý21.0mA Power supply 8¡«30V DC Temperature drift 0.01£¥ FS / 1 Long-term stability ¡Ü0.1 per year or 0.05£¥ per year Ambient -40¡«+85
MS183 , a smart 2-wire in-head and dual-input transmitter module with HART® -protocol, has measurement input for resistance Thermometers (RTD), thermocouples, resistance or millivolt signals in 2-, 3- or 4-wire connection and converts various input signals into a standard 4 to 20 mA analog(high selector, average value or D-value) output signal or 2-way digtal output signals with HART® -protocol after linear processing. The transmitter is programmable directly from PC or via the HART communication. Isolation also is provided between the input and output. A special signal can be set in advance while the sensor burnout or short. Primary Technical Characteristics Programmable Use PC or the hand operator Measuring range Set via PC or by the hand operator Input type Dual-input ( RTD, TC, R or Millivolt signal) Convert accuracy ¡Ü0.1£¥FS Cold junction accuracy ¡À1¡æ(TC) Output 4¡«20mA/20¡«4mA Electrical isolation output HART ¨CProtocol output (2-way) Max-load £¨V -16V£©/0.025A£¨Current output £© Limit current ¡Ü25mA Response time 1s Isolated voltage 1500VAC (input/output) Alarm signal Programmable Underranging linear drop to 3.8 mA Overranging linear rise to 20.5 mA Sensor break or short-circuit: ¡Ü3.6mA or ¡Ý21.0mA Automatic switching while sensor damaged Power supply 16¡«30V DC Temperature drift 0.01£¥ FS/1¡æ Long-term stability ¡Ü0.1¡æ per year or 0.05 £¥per year.
• Universal PC programmable (PCP) • 2 wire technology, 4 to 20 mA analogue output • High accuracy in total ambient temperature range • Configuration during measurement using configuration kit • Customer specific measurement range setting • Wide measurement range, according to requirement Field of application • PC programmable (PCP) Temperature head transmitter for converting the input signal into a standard 4 to 20 mA analog output signal • Input: Resistance thermometer (RTD) Pt100 • Configuration using a PC with MS180 configuration kit (MS180-PC). Appearance and Size (in mm) NOTE: When order, please specify the measuring range, we’ll offer programming tool if needed.