Vacuum Circuit Breaker HVD7 40.5KV 1250A outdoor HV AC VCB from Hubei JUCRO Electric
1. Introduction
HVD7 40.5KV 1250A outdoor HV AC vacuum circuit breaker VCB has many visual advantages like reasonable design, fashionable appearance, high safety and reliability, simple maintenance, long electric life. It is the ideal upgraded products of 35KV outdoor oil circuit breakers.
HVD7-40.5 1250A vacuum circuit breaker is applicable for three-phase power system of AC 50HZ.It is used to make and break the load current ,overload current and short-circuit current.
2. Applicable environment
2.1The ambient temperature should be -30degree~ +40degree(-40degree in the frosty area);
2.2Altitude should not exceed 2000m(over 2000m is plateau type);
2.3The wind pressure should not exceed 700Pa(equal to wind speed 34m/s);
2.4Air pollution degree: 3,that of antifouling type:4;
2.5The installation site should be free from the fire, explosion, chemical corrosion and serious vibration.
Model No.: TD 12kv 1250A 31.5KA (JUC618) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage: 42 KV Rated lightning impulse withstand voltage: 75 KV Rated short circuit breaking current: 31.5KA Rated short circuit making current(peak value): 80KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 31.5KA Rated withstand current(peak value): 80KA Rated duration of short circuit: 4S Mechanical life: 20,000 times Closing force due to bellows and atmosphere: 120±50N Force required to hold contacts opening at full stroke: 190±50N Circuit resistance at lowest rated contacts force: =20µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1 mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 3150±200 N Contacts bouncing duration at closing operation: =2 ms Contacts re-bouncing clearance at opening operation: =2 mm Synchronism of three phases: =1 ms
Model No.: TD 12kv 1250A 31.5KA (JUC619A) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage: 48 KV Rated lightning impulse withstand voltage: 85 KV Rated short circuit breaking current: 31.5KA Rated short circuit making current(peak value): 80KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 31.5KA Rated withstand current(peak value): 80KA Rated duration of short circuit: 4 s Mechanical life: 10,000 times Closing force due to bellows and atmosphere: 120±50 N Force required to hold contacts opening at full stroke: 190±50 N Circuit resistance at lowest rated contacts force: =20µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1 mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 3150±200 N Contacts bouncing duration at closing operation: =2 ms Contacts re-bouncing clearance at opening operation: =2 mm Synchronism of three phases: =1 ms * It Needs additional insultating protection.
Model No.: TD 12kv 1250A 25KA (JUC613) vacuum interrupter for VCB Main technical parameters Rated voltage: 12 KV Rated current: 1250A Rated power frequency withstand voltage: 42 KV Rated lightning impulse withstand voltage: 75 KV Rated short circuit breaking current: 25KA Rated short circuit making current(peak value): 63KA Breaking operations under rated short circuit breaking current: 30 times Rated short time withstand current: 25KA Rated withstand current(peak value): 63KA Rated duration of short circuit: 4S Mechanical life: 20,000 times Closing force due to bellows and atmosphere: 120±50N Force required to hold contacts opening at full stroke: 190±50N Circuit resistance at lowest rated contacts force: =20µO Storage life: 20 years Limiting abrasion of contacts: 3 mm Mechanical requiements of vacuum circuit breaker Clearance between opening contacts: 11±1mm Average opening speed(Contacts closing position~75% contacts opening distance): 1.1±0.2 m/s Average closing speed(30% contacts opening distance~contacts closing position): 0.6±0.2 m/s Rated contacts pressure: 2000±200N Contacts bouncing duration at closing operation: =2ms Contacts re-bouncing clearance at opening operation: =2mm Synchronism of three phases: =1ms
1. Introduction HVD7 33KV 36kv outdoor HV AC vacuum circuit breaker VCB has many visual advantages like reasonable design, fashionable appearance, high safety and reliability, simple maintenance, long electric life. It is the ideal upgraded products of 35KV outdoor oil circuit breakers. HVD7-40.5 vacuum circuit breaker is applicable for three-phase power system of AC 50HZ.It is used to make and break the load current ,overload current and short-circuit current. 2. Applicable environment 3.1The ambient temperature should be -30degree~ +40degree(-40degree in the frosty area); 3.2Altitude should not exceed 2000m(over 2000m is plateau type); 3.3The wind pressure should not exceed 700Pa(equal to wind speed 34m/s); 3.4Air pollution degree: 3,that of antifouling type:4; 3.5The installation site should be free from the fire, explosion, chemical corrosion and serious vibration. 1. Main technical parameters Rated voltage: 33kv 36KV 1 minute power frequency withstand voltage, dry test: 95 kv 1 minute power frequency withstand voltage, wet test: 80 kv Lightning impulse withstand voltage(peak value): 185 kv Rated current: 1600A / 2000A Rated short-circuit breaking current: 20KA, 25KA, 31.5KA Rated short-circuit making current(peak): 50KA, 63KA, 80KA Rated operating sequence: O-0.3s-CO-180s-CO Rated short-time withstand current: 20KA, 25KA, 31.5KA Rated peak withstand current: 50KA, 63KA, 80KA Rated short-circuit duration: 4 s Rated control voltage: AC220,110;DC220,110 Rated short-circuit breaking current break times: 20 times Full-break time:
Instrumentation circuits cable is used for computer based automatic control system, especially for computer distributed control system, transmission of production device process variable detection, control, interlocking, alarm lamp analog and digital signals, the product has excellent anti-interference performance, long-term working temperature -40~105.
10 To 40 Degree C Stainless Steel K Type Thermocouples, For Industrial IN tune with diversified applications, we are engaged in offering an excellent quality K Type Thermocouples. Our offered thermocouples are manufactured with precision using advance techniques in order to meet various needs of customers. Additionally, a series of quality tests are performed by our quality controllers on these thermocouples so as to eradicate any defect from this range.
LV power air circuit-breakers and switch-disconnectors Masterpact Merlin Gerin Masterpact circuit breakers are used to protect and control low-voltage distribution systems. They may be installed in main LV switchboards (incoming units, main and secondary outgoers). Masterpact is a complete range offering a large selection of performance levels: c ratings from 800 to 6300 A AC, from 1000 to 8000 A DC; c breaking capacity from 40 to 150 kA rms; c operational voltages 690 V AC, 1000 V DC.
VACCUM CIRCUIT BREAKER ALL TYPE OF ABB VACCUM CIRCUIT BREAKER VD4 12.12.25 , VD4 12.12.40, VD4 07.12.25.... MANY MORE 11 KV , 33KV . VD4Medium voltage vacuum circuit-breaker12 kV - 1250...4000 A - 63 kA36/40.5 kV - 630...3150 A - 16...40 kAMedium Voltage Products The VD4 are a synthesis of the renownedtechnology in designing and constructing vacuuminterrupters embedded in resin poles, and ofexcellency in design, engineering and productionof medium voltage circuit-breakers.Embedding the interrupter in resin makes thecircuit-breaker poles particularly sturdy andprotects the interrupter against shocks, accumula-tion of dust and humidity.The vacuum interrupter houses the contacts andmakes up the interrupting chamber.
GBCDG21AF103ZMCH 1 POLE INV.TIME O/C OR E/F RELAY WITH IN Model No : CDG21AF103ZM(M) CDG21/CAG17(MRK-III) APPLICATION - E/F BURDEN / D.M.T - 3 VA / 3 SEC. C.T. SECONDARY - 5 AMP C.T. CASE SIZE - 1D V 10T CONTACTS (S/R OR H/R) - 2 N/O S/R E/F SETTING - 1 - 4 Amps. FLAG - YES FREQUENCY - 50 HZ HIGH SET TYPE - CAG17 HIGHSET CONTACTS - 2M S/R HIGHSET E/F SETTING - 5 - 40 Amps. MOUNTING - FLUSH Name Plate RFG9126 696 Outline Diagram MFJ 012