1100 volts grade, LT Cable, multiple core, Cross linked Polyethylene (XLPE) insulated, PVC sheathed, Armoured power cables.
Cable Standard
BS 6500 & IS 694:2010, IEC 60227
Silent Features
- High flexibility
- Excellent resistant to moisture, abrasion,
grease, oil
- Long Life
- Excellent mechanical & electrical properties
Technical Data
Working Temp : Max.+70�°C
Nominal Voltage : 1.1 KV
Test Voltage : 3.0 KV
Min. Bending Radius : 6 x Cable Diameter
Standard Packing
Coils 100, 200, 300 , 500, 1000m
Conductor
Flexible Bare Bunch Copper as per
IS:8130
Insulation
PVC As Per IS:5831
Inner Sheath
PVC
Outer Sheath
PVC As Per IS:5831
Core Color
As per IEC 60227 3C -Blue, Brown, Black or Yellow/
Green, 4C -Blue, Brown, Black, Grey or Yellow/Green
As per IS 694 : 2010 - 3C - Red, Yellow and Blue
4C - Red, Yellow, Blue and Green
Application
Ideal For Irrigation Pumps, Drinking Water Supply
Pumps, Submersible Pump Motor Power Supply.
Cable Standard
DIN VDE 0282 PART 810, IEC 245 & BS 6007,
BS 6899
Silent Features
- Temperature range -40�° to +90�°
- Excellent Impact Resistant
- Excellent Weather Resistant
Technical Data
Operating Temp : Temp. range -40 to +90
Nominal Voltage : 1.1 KV
Test Voltage : 2.5 KV
Min. Bending Radius : 6 x Cable Diameter
Standard Packing
Coils 100, 200,300, 500, 1000m
Conductor
Flexible Bare Bunch Copper as per
IS:8130, IEC 60228
Insulation
EPR Rubber as per IS:6380,
VDE 0282 (Part-1)
Inner Sheath
NBR/TPR Rubber as per IS:6380,
VDE 0282 (Part-1)
Outer Sheath : NBR/TPR Rubber as per IS:6380,
VDE 0282 (Part-1)
Core Color
As per IEC 60227 3C - Blue, Brown, Black or Yellow/
green, 4C - Blue, Brown, Black, Grey or Yellow/green
As per IS 694 : 2010 -3C - Red, Yellow and Blue
4C - Red, Yellow, Blue and Green
Application
Ideal For Irrigation Pumps, Drinking Water Supply Pumps & Submersible Motor Power Supply.
Cable Standard
According to DIN 72551-6 & ISO 6722 B
JIS C 3406, JASO D 611/608, IS 2465,
BS 6862 : PART 1
Cable Features
- Excellent flexibility
- The NESKEB Auto cables is impervious
to water, petrol, diesel, acids, engine and
lubricating oils and grease resistant
- High mechanical strength
- Excellent flame retardant properties
- Excellent mechanical & electrical properties
Standard Packing
Coils 100, 200, 500 and 1000m
Conductor
Flexible Bare Copper Wire
Insulation
Pvc Insulation
Cables Type
FLRY-A and FLRY-B
Color
Blue, Black, Brown, Grey, Orange,
Pink, Red, Violet, White, Green,
Yellow, Yellow / Green, Lining Strip
Color Also and as per Customer
Requirement
Temperature
20�?�°c to 105�?�°c
Application
These cables are used as original equipment's
for wiring automobiles and in the auto harnesses
Cable Standard
SAE J1127 VDE 0295, IEC 60228,
IS 2465, BS 6862
Cable Features
- Excellent flexibility
- The NESKEB Auto cables is impervious
to water, petrol, diesel, acids, engine and
lubricating oils and grease resistant
- High mechanical strength
- Excellent flame retardant properties
- Excellent mechanical & electrical properties
- Special heat resistant insulation
- Minimum bending radius
Standard Packing
Coils 25, 50, 100, 200 And 500m.
Conductor
Flexible Battery Cables: Flexible bare copper class 5 conductors to IEC 60228
Extra Flexible Battery Cables: Flexible bare copper class 6 conductors to IEC 60228
Insulation
Flexible Battery Cables: HR PVC
Extra Flexible Battery Cables: HOFR(TPR Rubber)
Separator
Polyester tape over conductor for HOFR insulated extra flexible battery cables
Color : Red, Black
Application
These wires used low voltage circuit in automobiles such a Vehicles and Motor cycles. Where high flexibility is required.
Cable Features - Special heat resistant insulation - Higher current carrying capacity. - Fine copper wires - Highly thermal stable insulation - Excellent resistant to moisture, abrasion, grace, oil - Long Life - Excellent mechanical & electrical properties Cable Standard IS : 694 : 2010 & BS 6004, BS EN 50525-2-31 Application Fixed installation in conduits and under plaster, for appliance wiring and distribution stations. Standard Packing Coils 90 and 180m Conductor Flexible Bare Copper conductor class-2 and class-5 as per IS: 8130 EN 60228 Insulation HR/FR/FRLS-H/ZHFR Insulation compound with a high insulation resistance value as per IS:5831 Color Red, Yellow/green, Blue, Black, Brown, Grey, Orange, White, Green, Yellow Properties PVC Self-extinguishing and flame retardant according to EN 60332-1-2
Cable Standard
Generally conforms to IS 694:2010, IEC60228, BS 6004
Silent Features
- Special heat resistant insulation
- Higher current carrying capacity
- Fine copper wires
- Highly thermal stable insulation
- High electrical conductivity
- Long Life
- Excellent mechanical & electrical properties
Technical Data
Operating Temp : -10�?�°C to max.+90�?�°C
Nominal voltage : 1.1 KV
Test voltage : 3.0 KV
Standard Packing
Coils 100, 200, 500 and 1000m.
Conductor
Bare Copper class1 or class-2 as per IS:8130,
IEC 60228
Insulation
PVC FR, FRLS,HRFR,ZHFR as per IS:5831-1984
Color
Black, Green, Yellow/green or as per customer requirement
Application
Neskeb - Earth : Installation in surface mounted or embedded
conduits, or similar closed systems
Cable Standard
Generally conforms to DIN VDE 0281-5&2,
BS:6500, EN-50525-2-11, IEC 60227-5
Cable Features
- Special heat resistant insulation
- High current carrying capacity
- Less heat energy radiation
- Longer life
- High compatibility of cores
- Excellent resistance to moisture, abrasion,
grace, oil
- Excellent mechanical & electrical properties
- Insulation is highly thermal stable
- Harmonized acc. to European standards
Technical Data
Working Temp : -5C to 70C
Operating Temp : 20c to +80C
Nominal Voltage : 300/500 V
Test Voltage : 2000V
Min. Bending Radius : 6x Cable Diameter
Standard Packing
Coils 100, 200, 500 and 1000m
Conductor
Annealed flexible bare Copper
(Class 5 - Flexible Plain Copper)
according to VDE 0295 IEC 60228.
Insulation
PVC T12 to according to
EN 50363-3, BS 7655
Sheath
PVC TM2.to according to
EN 50363-3, BS 7655
Color
White, Black, Blue or
as per customer order
Core Identification
2 Core - Blue & Brown
3 Core - Yellow/green, Blue, Brown
4 Core - Yellow/green, Blue, Brown, Black or
Yellow/green, Brown, Black, Grey
5 Core - Yellow/green, Blue, Brown, Black and Grey
Application
H05VV-F cordage is a flexible PVC insulated, PVC
jacketed harmonized cord recommended for use in
electronic and electrical equipment such as office.
Silent Features (FR and FRLS)
- Good Flame Retardant Properties
- Excellent resistant to moisture, abrasion, grace, oil
- Long Life
- Excellent mechanical & electrical properties
- Steam and boiling water resistant
Silent Features (ZHFR)
- Zero Halogen acid gas Evolution
- Non-corrosive and non-toxic insulation
- High-temperature resistant insulation
- Better Flame retardant property
- Excellent resistance to moisture, abrasion, grace, oil
- Long Life
Technical Data
Operating Temp : -10Cto max.+90C
Nominal voltage : 1.1 KV
Test voltage : 3.0 KV
Flame propagation : Flame retardant test
as per IS 10810-58,64, IEC 60332-1
Standard Packing
Coils 90m, 180m and 360m
Conductor
Annealed flexible bare Copper class-2
and class-5 Conductor
as per IS:8130-1984
Insulation
PVC FR, FRLS,HRFR,ZHFR
as per IS:5831-1984
Color
Red, yellow, Blue, Black, Brown, Grey, Orange, White,
Green, Yellow/green or as per customer requirement
Application
Fixed installation in conduits and under plaster, for appliance wiring &
distribution stations.
Fixed Wiring in Conduits & Building wire Application
Cable Standard
IS 694:2010, BS 6500
Silent Features
- High Flexibility
- Excellent resistant to moisture, abrasion,
grace, oil
- Long Life
- Excellent mechanical & electrical properties
Technical Data
Working Temp : Max.+70�°C
Nominal Voltage : 1.1 KV
Test Voltage : 3.0 KV
Min. Bending Radius : 6 x Cable Diameter
Standard Packing
Coils 100, 200, 300 , 500, 1000m.
Conductor
Flexible Bare or Tinned Bunch
Copper as per IS:8130-1984
Insulation
PVC as per IS:5831-1984
Sheath
PVC as per IS:5831-1984
Core Color
As per IS 694 : 2010
2 Core â?? Red & Black
3 Core â?? Red, Black, Green or Red, Yellow and Blue
4 Core - Red, Yellow, Blue and Green or Black
Application
Ideal For industrial induction motor, power tools,
electrical machinery etc.
Cable Standard
Generally conforms to EN-50525-2-21,
DIN VDE 0282 part 810,IEC 245
Cable Features
- Special heat resistant insulation
- High current carrying capacity
- Less heat energy radiation
- Longer life
- High compatibility of cores
- Excellent resistant to moisture, abrasion,
grace, oil
- Excellent mechanical & electrical properties
- Insulation is highly thermal stable
- Harmonized acc. to European standards
Technical Data
Working Temp : -25�?�°C to 70�?�°C
Operating Temp : -20�?�°C to max. +90�?�°C
Nominal Voltage : 450/750 V
Test Voltage : 2500V
Min. Bending Radius : 6 x cable Diameter
Flame propagation : Flame retardant test
as per IEC 60332-1-2
Standard Packing
Coils 100, 200,500 and 1000m
Conductor
Flexible bare Class 5 copper
conductor according to
DIN VDE 0295,IEC 60228
Insulation
Rubber Type El-4 to
VDE 0282 Part-1
Sheath
Neoprene Jacket Rubber
Type EM-2
Color
White, Black, Blue or
as per customer order
Core Identification
1 Core - Black
2 Core - Blue & Brown
3 Core - Yellow/green, Blue, Brown
4 Core - Yellow/green, Blue, Brown, Black or
Yellow/Green, Brown, Black, Grey
5 Core - Yellow/Green, Blue, Brown, Black and Grey
Application
H07RN-F rubber insulated and sheathed cables
are intended for flexible connection to electrical
equipment. They are suitable for both indoor and
outdoor use in industrial and agricultural plant
and on construction sites
Cable Standard
IS 694:2010, BS 6500, IEC 60227
Silent Features
- Excellent flexibility
- Excellent resistant to moisture, abrasion,
grease, oil
- Long Life
- Excellent mechanical & electrical properties
Technical Data
Working Temp : Max.+70�°C
Nominal Voltage : 1.1 KV
Test Voltage : 3.0 KV
Min. Bending Radius : 6 x Cable Diameter
Standard Packing
Coils 100, 200,300, 500, 1000m
Conductor
Flexible Bare Bunch Copper as per
IS:8130
Insulation
PVC As Per IS:5831
Outer Sheath
PVC As Per IS:5831
Core Color
As per IS: 694:2010 â?? 3C - Red, Yellow, Blue, 4C -
Red, Yellow, Blue, Black
As per IEC:60227 - 3C - Black, Blue, Brown.
4C - Black, Blue, Brown, Green or Yellow/Green
Application
Ideal For Irrigation Pumps, Drinking Water Supply
Pumps, Submersible Pump Motor Power Supply
Cable Standard
DIN VDE 0282 part 810, IEC 245 & BS 6007,
BS 6899
Silent Features
- Temperature range -40�° to +90�°
- Exceptional long term performance
- Excellent Impact Resistant
- Excellent Weather Resistant
Technical Data
Operating Temp : -20�°c to Max.+90�°C
Nominal Voltage : 1.1 KV
Test Voltage : 3.0 KV
Min. Bending Radius : 6 x Cable Diameter
Standard Packing
Coils 100, 200,300, 500, 1000m
Conductor
Flexible Bare Bunch Copper as per
IS:8130, IEC 60228
Insulation
EPR Rubber
Outer Sheath
EPR Rubber
Core Color
3C - Red, Yellow, Blue, Or Black, Blue, Brown
4C- Red, Yellow, Blue, Black Or Black, Blue, Brown,
Green or Yellow/Green
Application
Ideal For Irrigation Pumps, Drinking Water Supply
Pumps, Submersible Pump Motor Power Supply.
Cable Standard
Generally conforms to, Based on IS:9857-1990 VDE 0282,
IEC 245-6, BS 6899
Silent Features
- Ultra high performance flexible welding lead, double insulated
for longer life and added safety
- Better flame retardant properties
- Outstanding toughness & durability
- High resistance to cuts, tears & abrasion
- Resistance to oil, solvents and chemicals
- Excellent ozone and weather resistant
Technical Data
Fixed Installation : -20C to max.+90C
Nominal Voltage : 600 V
Spark Test : 3.5 KV(ac)
Color : Orange / Black Jacket
Min. Bending Radius : 6 x Cable Diameter
Standard Packing
Coils 100, 200, 300 and 500m
Conductor
High conductivity, bare annealed copper flexible
conductor, EC copper class 5 & class 6 generally
conforms to IS:8130-1984, IEC 60228
Separation
Polyester tape
Insulation
Double Insulated/single insulated flexible Nitrile
rubber HOFR insulated as per IS:6380-1984
Color
Orange / Black Jacket
Current Rating
The maximum current ratings of flexible welding cables for different
duly cycles are based on an ambient air temperature of 25 C and a
maximum conductor temperature of 90 C. The percentage duly cycles
for various processes and applications are as follows:
- Automobile Welding : up to 100%
- Semi Automatic Welding : 30% to 85%
- Manual Welding : 0% to 60%
- Very intermittent or Occasional Welding : up to 20%
Voltage Drop
When total cable lengths in excess of 15mtr., are involved, it may be necessary
to use cables of larger cross section to ensure that the voltage drop is not
excessive & welding currents are maintained at adequate levels.
Application
Designed for the secondary (high current) connection to automatic or hand - held metal arc welding electrodes. It is suitable for flexible use
under rugged conditions, on assembly lines & conveyor systems, in machine tool and automatically operated line & spot welding machines
Electrical Characteristics
- Rated Voltage : 0.6/1 kV AC
- Rated DC Voltage : 1.5 kV
- Maximum Permitted DC Voltage : 1.8 kV (conductor/conductor,
non earthen system, circuit not under load)
- Maximum Permitted AC Voltage : 1 KV
- Working Voltage : DC 1000 V
- Spark Test : 6000 V. ac (8400 Vdc)
- Voltage Withstand : 6500 V as per EN50395 for 5 min
- Ampacity : According to requirements for cables for PV systems
Technical Data
- Ambient Temperature : -40C +90C
- Minimum Bending Radius : 5 x OD (fixed), 15 x OD
(occasional flexing)
- Flame retardant according to IEC 60332-1-2
- Low smoke emission < 20% as per ASTM D-2843
- Halogen free according to EN 50267-2-1/-2, IEC 60754-2
- Maximum Temperature at Conductor : 120C (20000h)
- Short Circuit Temperature : 200�?�°C (at conductor max. 5sec)
- Thermal Endurance Test : According to EN 60216-2
(temperature index +120C)
- High Temperature Pressure : Test according to EN 60811-3-1
- Excellent mechanical and electrical properties.
- UV resistance & OZONE resistance
- Flexibility & suitability for fast & easy installation
Cable Standard
EN 50618
Standard Packing
Coils 100, 200,300, 500, 1000m
Conductor
Flexible Electrolytic fine Tinned
copper class-5 conductor according
to IEC 60228
Insulation
XLPO (Crosslinked Halogen Free &
Flame Retardant)
Sheath
XLPO (Crosslinked Halogen Free &
Flame Retardant)
Color
Red, Black and also available black color with red lining.
Application
For Solar Panel, Solar Power Plant,
Solar Pump Installation.
Cable Standard
BS:5308 (172) IEC 189 (1&2)
Silent Features
- Wear & Tear Resistance
- Long Life
- Easy to Cable Slitting
- Fire Resistance
Technical Data
Working Temp : 70C / 90C / 105C
as per Insulation
Nominal Voltage : 300/500 V
Application
To Transmit signals from Field Instruments
to Control Penal with No. disturbance.
A.C. drive application
Standard Packing
Coils 100, 200, 500 & 1000m
Conductor
Annealed Plain Bare Copper or
Tinned Copper As per IEC 60228
Insulation
PVC/ XLPE/ PE/ LSZH/ EPR
Sheath
PVC/ Rubber/ LSZH/ FRLS
Type
Armoured or Unarmoured.
Elements
Insulated core/Pairs / Tried /
Quads Color / multi core cable
number marking on core
Shield
Aluminum mylar tape screen with
tinned copper drain wire individual
shielding or Overall Shielding
Braiding
Tinned copper braiding
as per requirement
Application
To Transmit signals from Field Instruments
to Control Penal with No. disturbance.
A.C. drive application