Cable Standard
Generally conforms to, Based on IS:9857-1990 VDE 0282,
IEC 245-6, BS 6899
Silent Features
- Ultra high performance flexible welding lead, double insulated
for longer life and added safety
- Better flame retardant properties
- Outstanding toughness & durability
- High resistance to cuts, tears & abrasion
- Resistance to oil, solvents and chemicals
- Excellent ozone and weather resistant
Technical Data
Fixed Installation : -20C to max.+90C
Nominal Voltage : 600 V
Spark Test : 3.5 KV(ac)
Color : Orange / Black Jacket
Min. Bending Radius : 6 x Cable Diameter
Standard Packing
Coils 100, 200, 300 and 500m
Conductor
High conductivity, bare annealed copper flexible
conductor, EC copper class 5 & class 6 generally
conforms to IS:8130-1984, IEC 60228
Separation
Polyester tape
Insulation
Double Insulated/single insulated flexible Nitrile
rubber HOFR insulated as per IS:6380-1984
Color
Orange / Black Jacket
Current Rating
The maximum current ratings of flexible welding cables for different
duly cycles are based on an ambient air temperature of 25 C and a
maximum conductor temperature of 90 C. The percentage duly cycles
for various processes and applications are as follows:
- Automobile Welding : up to 100%
- Semi Automatic Welding : 30% to 85%
- Manual Welding : 0% to 60%
- Very intermittent or Occasional Welding : up to 20%
Voltage Drop
When total cable lengths in excess of 15mtr., are involved, it may be necessary
to use cables of larger cross section to ensure that the voltage drop is not
excessive & welding currents are maintained at adequate levels.
Application
Designed for the secondary (high current) connection to automatic or hand - held metal arc welding electrodes. It is suitable for flexible use
under rugged conditions, on assembly lines & conveyor systems, in machine tool and automatically operated line & spot welding machines
Cable Standard According to DIN 72551-6 & ISO 6722 B JIS C 3406, JASO D 611/608, IS 2465, BS 6862 : PART 1 Cable Features - Excellent flexibility - The NESKEB Auto cables is impervious to water, petrol, diesel, acids, engine and lubricating oils and grease resistant - High mechanical strength - Excellent flame retardant properties - Excellent mechanical & electrical properties Standard Packing Coils 100, 200, 500 and 1000m Conductor Flexible Bare Copper Wire Insulation Pvc Insulation Cables Type FLRY-A and FLRY-B Color Blue, Black, Brown, Grey, Orange, Pink, Red, Violet, White, Green, Yellow, Yellow / Green, Lining Strip Color Also and as per Customer Requirement Temperature 20�?�°c to 105�?�°c Application These cables are used as original equipment's for wiring automobiles and in the auto harnesses
Cable Standard SAE J1127 VDE 0295, IEC 60228, IS 2465, BS 6862 Cable Features - Excellent flexibility - The NESKEB Auto cables is impervious to water, petrol, diesel, acids, engine and lubricating oils and grease resistant - High mechanical strength - Excellent flame retardant properties - Excellent mechanical & electrical properties - Special heat resistant insulation - Minimum bending radius Standard Packing Coils 25, 50, 100, 200 And 500m. Conductor Flexible Battery Cables: Flexible bare copper class 5 conductors to IEC 60228 Extra Flexible Battery Cables: Flexible bare copper class 6 conductors to IEC 60228 Insulation Flexible Battery Cables: HR PVC Extra Flexible Battery Cables: HOFR(TPR Rubber) Separator Polyester tape over conductor for HOFR insulated extra flexible battery cables Color : Red, Black Application These wires used low voltage circuit in automobiles such a Vehicles and Motor cycles. Where high flexibility is required.
Cable Standard Generally conforms to IS 694:2010, IEC60228, BS 6004 Silent Features - Special heat resistant insulation - Higher current carrying capacity - Fine copper wires - Highly thermal stable insulation - High electrical conductivity - Long Life - Excellent mechanical & electrical properties Technical Data Operating Temp : -10�?�°C to max.+90�?�°C Nominal voltage : 1.1 KV Test voltage : 3.0 KV Standard Packing Coils 100, 200, 500 and 1000m. Conductor Bare Copper class1 or class-2 as per IS:8130, IEC 60228 Insulation PVC FR, FRLS,HRFR,ZHFR as per IS:5831-1984 Color Black, Green, Yellow/green or as per customer requirement Application Neskeb - Earth : Installation in surface mounted or embedded conduits, or similar closed systems
Cable Standard Generally conforms to DIN VDE 0281-5&2, BS:6500, EN-50525-2-11, IEC 60227-5 Cable Features - Special heat resistant insulation - High current carrying capacity - Less heat energy radiation - Longer life - High compatibility of cores - Excellent resistance to moisture, abrasion, grace, oil - Excellent mechanical & electrical properties - Insulation is highly thermal stable - Harmonized acc. to European standards Technical Data Working Temp : -5C to 70C Operating Temp : 20c to +80C Nominal Voltage : 300/500 V Test Voltage : 2000V Min. Bending Radius : 6x Cable Diameter Standard Packing Coils 100, 200, 500 and 1000m Conductor Annealed flexible bare Copper (Class 5 - Flexible Plain Copper) according to VDE 0295 IEC 60228. Insulation PVC T12 to according to EN 50363-3, BS 7655 Sheath PVC TM2.to according to EN 50363-3, BS 7655 Color White, Black, Blue or as per customer order Core Identification 2 Core - Blue & Brown 3 Core - Yellow/green, Blue, Brown 4 Core - Yellow/green, Blue, Brown, Black or Yellow/green, Brown, Black, Grey 5 Core - Yellow/green, Blue, Brown, Black and Grey Application H05VV-F cordage is a flexible PVC insulated, PVC jacketed harmonized cord recommended for use in electronic and electrical equipment such as office.
Cable Standard Generally conforms to EN-50525-2-21, DIN VDE 0282 part 810,IEC 245 Cable Features - Special heat resistant insulation - High current carrying capacity - Less heat energy radiation - Longer life - High compatibility of cores - Excellent resistant to moisture, abrasion, grace, oil - Excellent mechanical & electrical properties - Insulation is highly thermal stable - Harmonized acc. to European standards Technical Data Working Temp : -25�?�°C to 70�?�°C Operating Temp : -20�?�°C to max. +90�?�°C Nominal Voltage : 450/750 V Test Voltage : 2500V Min. Bending Radius : 6 x cable Diameter Flame propagation : Flame retardant test as per IEC 60332-1-2 Standard Packing Coils 100, 200,500 and 1000m Conductor Flexible bare Class 5 copper conductor according to DIN VDE 0295,IEC 60228 Insulation Rubber Type El-4 to VDE 0282 Part-1 Sheath Neoprene Jacket Rubber Type EM-2 Color White, Black, Blue or as per customer order Core Identification 1 Core - Black 2 Core - Blue & Brown 3 Core - Yellow/green, Blue, Brown 4 Core - Yellow/green, Blue, Brown, Black or Yellow/Green, Brown, Black, Grey 5 Core - Yellow/Green, Blue, Brown, Black and Grey Application H07RN-F rubber insulated and sheathed cables are intended for flexible connection to electrical equipment. They are suitable for both indoor and outdoor use in industrial and agricultural plant and on construction sites
Electrical Characteristics - Rated Voltage : 0.6/1 kV AC - Rated DC Voltage : 1.5 kV - Maximum Permitted DC Voltage : 1.8 kV (conductor/conductor, non earthen system, circuit not under load) - Maximum Permitted AC Voltage : 1 KV - Working Voltage : DC 1000 V - Spark Test : 6000 V. ac (8400 Vdc) - Voltage Withstand : 6500 V as per EN50395 for 5 min - Ampacity : According to requirements for cables for PV systems Technical Data - Ambient Temperature : -40C +90C - Minimum Bending Radius : 5 x OD (fixed), 15 x OD (occasional flexing) - Flame retardant according to IEC 60332-1-2 - Low smoke emission < 20% as per ASTM D-2843 - Halogen free according to EN 50267-2-1/-2, IEC 60754-2 - Maximum Temperature at Conductor : 120C (20000h) - Short Circuit Temperature : 200�?�°C (at conductor max. 5sec) - Thermal Endurance Test : According to EN 60216-2 (temperature index +120C) - High Temperature Pressure : Test according to EN 60811-3-1 - Excellent mechanical and electrical properties. - UV resistance & OZONE resistance - Flexibility & suitability for fast & easy installation Cable Standard EN 50618 Standard Packing Coils 100, 200,300, 500, 1000m Conductor Flexible Electrolytic fine Tinned copper class-5 conductor according to IEC 60228 Insulation XLPO (Crosslinked Halogen Free & Flame Retardant) Sheath XLPO (Crosslinked Halogen Free & Flame Retardant) Color Red, Black and also available black color with red lining. Application For Solar Panel, Solar Power Plant, Solar Pump Installation.
Cable Standard BS:5308 (172) IEC 189 (1&2) Silent Features - Wear & Tear Resistance - Long Life - Easy to Cable Slitting - Fire Resistance Technical Data Working Temp : 70C / 90C / 105C as per Insulation Nominal Voltage : 300/500 V Application To Transmit signals from Field Instruments to Control Penal with No. disturbance. A.C. drive application Standard Packing Coils 100, 200, 500 & 1000m Conductor Annealed Plain Bare Copper or Tinned Copper As per IEC 60228 Insulation PVC/ XLPE/ PE/ LSZH/ EPR Sheath PVC/ Rubber/ LSZH/ FRLS Type Armoured or Unarmoured. Elements Insulated core/Pairs / Tried / Quads Color / multi core cable number marking on core Shield Aluminum mylar tape screen with tinned copper drain wire individual shielding or Overall Shielding Braiding Tinned copper braiding as per requirement Application To Transmit signals from Field Instruments to Control Penal with No. disturbance. A.C. drive application
Welding Cable.