Cable Standard
DIN VDE 0282 part 810, IEC 245 & BS 6007,
BS 6899
Silent Features
- Temperature range -40�° to +90�°
- Exceptional long term performance
- Excellent Impact Resistant
- Excellent Weather Resistant
Technical Data
Operating Temp : -20�°c to Max.+90�°C
Nominal Voltage : 1.1 KV
Test Voltage : 3.0 KV
Min. Bending Radius : 6 x Cable Diameter
Standard Packing
Coils 100, 200,300, 500, 1000m
Conductor
Flexible Bare Bunch Copper as per
IS:8130, IEC 60228
Insulation
EPR Rubber
Outer Sheath
EPR Rubber
Core Color
3C - Red, Yellow, Blue, Or Black, Blue, Brown
4C- Red, Yellow, Blue, Black Or Black, Blue, Brown,
Green or Yellow/Green
Application
Ideal For Irrigation Pumps, Drinking Water Supply
Pumps, Submersible Pump Motor Power Supply.
Cable Standard IS 694:2010, BS 6500, IEC 60227 Silent Features - Excellent flexibility - Excellent resistant to moisture, abrasion, grease, oil - Long Life - Excellent mechanical & electrical properties Technical Data Working Temp : Max.+70�°C Nominal Voltage : 1.1 KV Test Voltage : 3.0 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200,300, 500, 1000m Conductor Flexible Bare Bunch Copper as per IS:8130 Insulation PVC As Per IS:5831 Outer Sheath PVC As Per IS:5831 Core Color As per IS: 694:2010 â?? 3C - Red, Yellow, Blue, 4C - Red, Yellow, Blue, Black As per IEC:60227 - 3C - Black, Blue, Brown. 4C - Black, Blue, Brown, Green or Yellow/Green Application Ideal For Irrigation Pumps, Drinking Water Supply Pumps, Submersible Pump Motor Power Supply
Cable Standard DIN VDE 0282 PART 810, IEC 245 & BS 6007, BS 6899 Silent Features - Temperature range -40�° to +90�° - Excellent Impact Resistant - Excellent Weather Resistant Technical Data Operating Temp : Temp. range -40 to +90 Nominal Voltage : 1.1 KV Test Voltage : 2.5 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200,300, 500, 1000m Conductor Flexible Bare Bunch Copper as per IS:8130, IEC 60228 Insulation EPR Rubber as per IS:6380, VDE 0282 (Part-1) Inner Sheath NBR/TPR Rubber as per IS:6380, VDE 0282 (Part-1) Outer Sheath : NBR/TPR Rubber as per IS:6380, VDE 0282 (Part-1) Core Color As per IEC 60227 3C - Blue, Brown, Black or Yellow/ green, 4C - Blue, Brown, Black, Grey or Yellow/green As per IS 694 : 2010 -3C - Red, Yellow and Blue 4C - Red, Yellow, Blue and Green Application Ideal For Irrigation Pumps, Drinking Water Supply Pumps & Submersible Motor Power Supply.
Cable Standard BS 6500 & IS 694:2010, IEC 60227 Silent Features - High flexibility - Excellent resistant to moisture, abrasion, grease, oil - Long Life - Excellent mechanical & electrical properties Technical Data Working Temp : Max.+70�°C Nominal Voltage : 1.1 KV Test Voltage : 3.0 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200, 300 , 500, 1000m Conductor Flexible Bare Bunch Copper as per IS:8130 Insulation PVC As Per IS:5831 Inner Sheath PVC Outer Sheath PVC As Per IS:5831 Core Color As per IEC 60227 3C -Blue, Brown, Black or Yellow/ Green, 4C -Blue, Brown, Black, Grey or Yellow/Green As per IS 694 : 2010 - 3C - Red, Yellow and Blue 4C - Red, Yellow, Blue and Green Application Ideal For Irrigation Pumps, Drinking Water Supply Pumps, Submersible Pump Motor Power Supply.
3 Core & 4 Core Submersible Flat & Round Cables CONDUCTOR: Bunched flexible EC grade bright annealed bare, copper conductor according to international standards like IS 8130, BS 6360, IEC 228 & VDE 0295. INSULATION: PVC Compound resistant to water, oils, grease etc. SHEATH: Flexible PVC sheath with high abrasion resistance APPLICATION: With submersible pumps in a deep well and irrigation equipment, Drinking Water Supply, Dewatering applications, Swimming Pools, Fountains, Offshore Drilling Rigs SPECIAL FEATURES: Generally Conforming to : CENELEC HD 21, IEC 60227, BS 6500, DIN VDE 0281, IS 694, Excellent resistant to moisture, abrasion, grease, oil. Excellent mechanical & electrical properties, Temperature range -15C to +70C
Silent Features (FR and FRLS) - Good Flame Retardant Properties - Excellent resistant to moisture, abrasion, grace, oil - Long Life - Excellent mechanical & electrical properties - Steam and boiling water resistant Silent Features (ZHFR) - Zero Halogen acid gas Evolution - Non-corrosive and non-toxic insulation - High-temperature resistant insulation - Better Flame retardant property - Excellent resistance to moisture, abrasion, grace, oil - Long Life Technical Data Operating Temp : -10Cto max.+90C Nominal voltage : 1.1 KV Test voltage : 3.0 KV Flame propagation : Flame retardant test as per IS 10810-58,64, IEC 60332-1 Standard Packing Coils 90m, 180m and 360m Conductor Annealed flexible bare Copper class-2 and class-5 Conductor as per IS:8130-1984 Insulation PVC FR, FRLS,HRFR,ZHFR as per IS:5831-1984 Color Red, yellow, Blue, Black, Brown, Grey, Orange, White, Green, Yellow/green or as per customer requirement Application Fixed installation in conduits and under plaster, for appliance wiring & distribution stations. Fixed Wiring in Conduits & Building wire Application
Cable Standard IS 694:2010, BS 6500 Silent Features - High Flexibility - Excellent resistant to moisture, abrasion, grace, oil - Long Life - Excellent mechanical & electrical properties Technical Data Working Temp : Max.+70�°C Nominal Voltage : 1.1 KV Test Voltage : 3.0 KV Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200, 300 , 500, 1000m. Conductor Flexible Bare or Tinned Bunch Copper as per IS:8130-1984 Insulation PVC as per IS:5831-1984 Sheath PVC as per IS:5831-1984 Core Color As per IS 694 : 2010 2 Core â?? Red & Black 3 Core â?? Red, Black, Green or Red, Yellow and Blue 4 Core - Red, Yellow, Blue and Green or Black Application Ideal For industrial induction motor, power tools, electrical machinery etc.
Cable Standard Generally conforms to EN-50525-2-21, DIN VDE 0282 part 810,IEC 245 Cable Features - Special heat resistant insulation - High current carrying capacity - Less heat energy radiation - Longer life - High compatibility of cores - Excellent resistant to moisture, abrasion, grace, oil - Excellent mechanical & electrical properties - Insulation is highly thermal stable - Harmonized acc. to European standards Technical Data Working Temp : -25�?�°C to 70�?�°C Operating Temp : -20�?�°C to max. +90�?�°C Nominal Voltage : 450/750 V Test Voltage : 2500V Min. Bending Radius : 6 x cable Diameter Flame propagation : Flame retardant test as per IEC 60332-1-2 Standard Packing Coils 100, 200,500 and 1000m Conductor Flexible bare Class 5 copper conductor according to DIN VDE 0295,IEC 60228 Insulation Rubber Type El-4 to VDE 0282 Part-1 Sheath Neoprene Jacket Rubber Type EM-2 Color White, Black, Blue or as per customer order Core Identification 1 Core - Black 2 Core - Blue & Brown 3 Core - Yellow/green, Blue, Brown 4 Core - Yellow/green, Blue, Brown, Black or Yellow/Green, Brown, Black, Grey 5 Core - Yellow/Green, Blue, Brown, Black and Grey Application H07RN-F rubber insulated and sheathed cables are intended for flexible connection to electrical equipment. They are suitable for both indoor and outdoor use in industrial and agricultural plant and on construction sites
Cable Standard Generally conforms to, Based on IS:9857-1990 VDE 0282, IEC 245-6, BS 6899 Silent Features - Ultra high performance flexible welding lead, double insulated for longer life and added safety - Better flame retardant properties - Outstanding toughness & durability - High resistance to cuts, tears & abrasion - Resistance to oil, solvents and chemicals - Excellent ozone and weather resistant Technical Data Fixed Installation : -20C to max.+90C Nominal Voltage : 600 V Spark Test : 3.5 KV(ac) Color : Orange / Black Jacket Min. Bending Radius : 6 x Cable Diameter Standard Packing Coils 100, 200, 300 and 500m Conductor High conductivity, bare annealed copper flexible conductor, EC copper class 5 & class 6 generally conforms to IS:8130-1984, IEC 60228 Separation Polyester tape Insulation Double Insulated/single insulated flexible Nitrile rubber HOFR insulated as per IS:6380-1984 Color Orange / Black Jacket Current Rating The maximum current ratings of flexible welding cables for different duly cycles are based on an ambient air temperature of 25 C and a maximum conductor temperature of 90 C. The percentage duly cycles for various processes and applications are as follows: - Automobile Welding : up to 100% - Semi Automatic Welding : 30% to 85% - Manual Welding : 0% to 60% - Very intermittent or Occasional Welding : up to 20% Voltage Drop When total cable lengths in excess of 15mtr., are involved, it may be necessary to use cables of larger cross section to ensure that the voltage drop is not excessive & welding currents are maintained at adequate levels. Application Designed for the secondary (high current) connection to automatic or hand - held metal arc welding electrodes. It is suitable for flexible use under rugged conditions, on assembly lines & conveyor systems, in machine tool and automatically operated line & spot welding machines