JDZX10-12 voltage transformer, epoxy resin casting and single pole insulated VT, is widely used indoor for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50-60Hz and highest voltage for equipment 12 kV. Usage Terms J: Voltage transformer D: Single-phase Z: Casting insulation X: Residual voltage winding 10: Design No. 12: Rated voltage Main technical parameter 1. Rated primary voltage:11/kV or 10/kV etc. 2. Rated secondary voltage:100/V?110/V ? 115/V? 120/V 3. Rated voltage of residual voltage windings:100/ 3V ?110/ 3V? 115/ 3V? 120/ 3V 4. Burden power factor: cosF=0.8(lagging) 5. Standards: IEC60044-2.2003 Instrument transformers-Part2: Inductive Voltage transformers Other technical parameters pls see as follow: x1204.png Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.
A disadvantage of the classical P core design has always been the narrow wire slots, making it diffi cult to make strong coil formers with integrated solder pins. In the PTS design this problem is solved by cutting away the sides of both core halves. This creates ample room for wires and coil former fl anges. A range of special PTS coil formers is available but also most standard P core accessories can be used.
A disadvantage of the classical P core design has always been the narrow wire slots, making it diffi cult to make strong coil formers with integrated solder pins. In the PT design this problem is solved by cutting away the sides of one core half. This creates ample room for wires and coil former fl anges. A range of special PT coil formers is available but also most standard P core accessories can be used.
Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA,1s Rated insulation level 12/42/75 kV Ambient temperature 25~40 Altitude Up to 1000m above sea level Indoor device Standards The product performance is in accordance with GB20840.1 GB20840.2 and IEC61869-1 IEC61869-2 standards.
FEATURES Most cost-effective Faster installation Safe and easy installations High accuracy 0.5 Holding wire diameter: 32mm Ratio ranging from 60/1A to 600/5A CE, UL PARAMETERS Technical parameters Standards IEC/EN60044-1 & IEC61010-1 & IEC61869-2&ANSI C57.13 Ratio 400: 5 or 200:5 , customized Nominal input current Primary current 100A/150A/200A/300A/400A/500A/600A Overload withstand 1.2 times rated current continuously Accuracy 0.2%, 0.5 %, 1%/60Hz System Voltage 720V(0.72kV) Output signal 1A or 5A 333mV AC or 100mV-2V optional Burden 2.5VA Frequency range 40 Hz-500 Hz Dielectric strength 3KV 50Hz/60Hz at 1 minute Output Standard 2.5 meter cable Max. jaw opening 32 mm Mechanical parameters Dimensions (DH) (mm) 110mm130mm 41mm Weight(g) 700 Operating conditions Operating temperature -25 C to +55 C Relative Humidity 0-85% non-condensing Altitude
For current tansformer: ratio: 5a/5a to 5000a/5a & 5a/1a to 5000a/1a, va/cl ; 0 va to 50va cl from 0.2, 0.2s, 0.5, 0.5s, 1.0, 3.0 5.0 Str: upto 40ka/3, upto 33 kv For potential transformer: 1phase & 3 phase draw out type upto 33 kv, class from 0.2 to 1.0 Voltage factor : 1.2 continous , 1.5 for 30sec.& 1.9 for 8 hrs
GE TRANSFORMER PROTECTION RELAY The T60 Transformer Protection System is part of the Universal Relay (UR) series of products. It is a microprocessor-based relay for protection of small, medium, and large three-phase power transformers. The relay can be configured for a maximum of six three-phase current inputs and six ground current inputs, and can satisfy applications with transformer windings connected between two breakers, such as in a ring bus or in breaker-and-a-half configurations. The T60 performs magnitude and phase shift compensation internally, eliminating requirements for external CT connections and auxiliary CTs.
These Current Transformers are manufactured in Wound Primary type and Window type construction. It is manufactured using Automatic Pressure Gelation casting and Vacuum Casting Technique. It ranges from 3.3 kV to 33 kV.
These Current Transformers are manufactured in Wound Primary type and Window type construction. It is manufactured using Automatic Pressure Gelation casting and Vacuum Casting Technique. It ranges from 3.3 kV to 33 kV.