JDZX10-12 voltage transformer, epoxy resin casting and single pole insulated VT, is widely used indoor for measuring current, electric energy and protective relaying in the isolated neutral system with the frequency 50-60Hz and highest voltage for equipment 12 kV.
Usage Terms
J: Voltage transformer
D: Single-phase
Z: Casting insulation
X: Residual voltage winding
10: Design No.
12: Rated voltage
Main technical parameter
1. Rated primary voltage:11/kV or 10/kV etc.
2. Rated secondary voltage:100/V?110/V ? 115/V? 120/V
3. Rated voltage of residual voltage windings:100/ 3V ?110/ 3V? 115/ 3V? 120/ 3V
4. Burden power factor: cosF=0.8(lagging)
5. Standards: IEC60044-2.2003 Instrument transformers-Part2: Inductive Voltage transformers
Other technical parameters pls see as follow:
x1204.png
Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.
LZZBJ9-12A1(A2) current transformer, epoxy resin casting insulation and fully enclosed support construction, encloses primary & secondary windings and annular core in the epoxy resin casting body. The product has the feature of light weight, omni-directional installation, withstanding nastiness and dampness. It is widely used for measuring current, electric energy and protective relaying in the electrical system with the rated frequency 50- 60Hz and highest voltage for equipment 7.2 kV /12 kV . Main technical parameter 1. Rated voltage: 6.6 kV or 11 kV etc. 2.Rated secondary current: 5A?1A 3.Rated insulation level: 7.2/20/60 kV or 12/28/75 kV 4.Standards: IEC60044-1.2003 Part 1: Instrument transformers-Part1: Current transformers 5.Other technical parameter pls see as follows Rated transformation ratio(A) Accuracy classes combination Rated output(VA) (ALF) (FS) Short-time thermal current Ith(kA/S) Rated dynamic current Idyn(kA) Measuring Protective 0.2(S) 0.5 10P 10-200/5 0.2(S)/0.2(S) 0.2(S)/0.5 0.2(S)/10P 0.5/10P 0.2S/0.5/10P 0.2/0.5/10P 10 15 15 15 10 15 20 5 (10) 150I1n 375I1n 300/5 31.5 80 400/5 31.5 80 500/5 40 100 600/5 50 125 800/5 20 63 125 1000/5 80 160 1200~1500/5 80 160 1500~2000/5 100 160 2000~3150/5 130 160 Rated transformation ratio(A) Accuracy classes combination Rated output(VA) (ALF) (FS) Short-time thermal current Ith(kA/S) Rated dynamic current Idyn(kA) Measuring Protective 0.2(S) 0.5 10P 10-200/5 0.2S//0.5/ 10P 0.5/0.5/10P 10 15 15 15 20 10 15 5 (10) 150I1n 375I1n 300/5 31.5 80 400/5 31.5 80 500/5 40 100 600/5 50 125 800/5 63 125 1000/5 80 160 1200~1500/5 80 160 1500~2000/5 100 160 2000~3150/5 130 160 Remarks: Upon request we are glad to offer transformers according to other standards or with non-standard technical specs.
Spec: Voltage Transformer (Brand: M/S Tianshui Changkai) IL: 12/45/75kV 1Kw, 50Hz, 1.9Un:8h
Transformer can transformer the voltage of a network into the voltage matching the system or load and fulfill power transferring and distributing.Taking the place of transformers with silicon steel core, AMDT can be widely applied in outdoor power distribution networks systems, which is magnificently energy saving and can lessen air pollution. It is especially applicable for areas with insufficient power supply and fluctuating load and where daily maintenance is hard. Since the transformer adopts a fully sealed structure, the insulating oil and the insulating medium are not polluted by the atmosphere, so it can be carried out in a humid environment, making the ideal power distribution equipment in the urban and rural distribution networks.
We manufacture transformer bushings for outdoor and indoor applications and our manufacturing program includes the following ranges : 1. Low voltage bushings in accordance with DIN 42539 - 1 kV , 250 A Low voltage bushing AB-250 - 1 kV ,630 A Low voltage bushing AB-630 - 1 kV ,1000 A Low voltage bushing AB-1000 - 1kV, 2000 A Low voltage bushing AB-2000 - 1 kV,3150 A Low voltage bushing AB-3150 2. Medium voltage Bushings in accordance with EN50180 & DIN42531 - 12.5kV,250A Indoor type transformer bushing 10Ni-250A - 12.5 kV,250A Outdoor type transformer bushing 10Nf -250A - 24 kV ,250A Outdoor type transformer bushing 20NF-250A - 36 kV,250A Outdoor type transformer bushing 30NF-250A
Product Details The Transformer used in the power supply unit manufactured as per the UL norms. Transformer will be potted/sealed in an enclosure using Epoxy (mixture of Resin & Hardener) which ensures high reliability and efficiency. The enclosure is made up of Prime Stainless Steel material SS 304 grade (also carbon steel with powder coated enclosure can be provided on request ) Circuit breaker(25A x 4) provided for circuit protection. Block Terminals will provide the easiest way for the customer to connect the secondary tappings. Photocell and timer connected as per the customer needs Technical Details Wattage - 1200w Frequency - 50/60 Hz Pry. voltage - 120V Sec... voltages As per customer requirements Insulation class F, H Max. regulation 7.5% Dielectric 2000v, primary to secondary for 1 second. Dielectric2000v, all windings to lamination for 1 second.
Product Details The Transformer used in the power supply unit manufactured as per the UL norms. Transformer will be potted/sealed in an enclosure using Epoxy (mixture of Resin & Hardener) which ensures high reliability and efficiency. The enclosure is made up of Prime Stainless Steel material SS 304 grade (also carbon steel with powder coated enclosure can be provided on request ) Circuit breaker(25A x 3) provided for circuit protection. Block Terminals will provide the easiest way for the customer to connect the secondary tappings. Photocell and timer connected as per the customer needs Technical Details Wattage - 900w Frequency - 50/60 Hz Pry. voltage - 120V /277V Sec... voltages As per customer requirements Insulation class F, H Max. regulation 7.5% Dielectric 2000v, primary to secondary for 1 second. Dielectric 2000v, all windings to lamination for 1 second.
Product Details The Transformer used in the power supply unit manufactured as per the UL norms. Transformer will be potted/sealed in an enclosure using Epoxy (mixture of Resin & Hardener) which ensures high reliability and efficiency. The enclosure is made up of Prime Stainless Steel material SS 304 grade (also carbon steel with powder coated enclosure can be provided on request ) Circuit breaker(25A x2) provided for circuit protection. Block Terminals will provide the easiest way for the customer to connect the secondary tappings. Photocell and timer connected as per the customer needs Technical Details Wattage - 600w Frequency - 50/60 Hz Pry. voltage - 120V /277V Sec... voltages 12, 13, 14, 15V Insulation class F, H Max. regulation 10% Dielectric 2000v, primary to secondary for 1 second. Dielectric 2000v, all windings to lamination for 1 second.
Description Multi Tap Transformers allow greater flexibility in managing multiple wire runs by moving cables up and down the multi range. Our Resin Sealed Transformers ensure highest possible efficiency & reliability. Features Low Voltage Transformer ranging from 75 W - 1200W 120, 277 /12, 13, 14, 15V with Toroidal /EI. 50/60 Hz Protection for each output circuit. Photo cell Option Rainproof Enclosure Stainless Steel / Powder Coated.
The transformer core is made of imported high-quality cold-rolled silicon steel sheet, which greatly reduces no-load loss and no-load current. The core is tightly bound to ensure the compactness and reduce noise. *� The high and low voltage windings are� made of oxygen-free copper. The low voltage winding of 500KVA and below is of double-layer cylinder structure, of 630kVA and above adopt double helix or four helix structure. High-voltage winding adopts multi-layer cylinder structure. Dyn11 is used in the transformer connection group to reduce the influence of harmonics on the power grid and improve the quality of power supply. *� The transformer is a fully sealed structure, with three coats of primer and one coat of finish paint applied on the inner and outer surfaces. The product is salt fog proof, moisture proof and fungus-proofing, beautiful, durable and reliable The measured noise value is lower than the standard and maintenance free under normal operation.