1 RFT8100 wireless temperature and humidity detection system is composed by wireless temperature detection probes, humidity detection probes and display terminals. Adopting the advanced wireless temperature detection technology, RFT8100 transmits and displays the real time value detected from the local detection probes for the purpose of inspecting temperature and humidity on-site routinely. The alarm relay sends out signal when the temperature and humidity data exceeds or lowers the setting alarm value, and the alarm points can be found quickly by checking the alarm information. RFT8100 also provides curve diagram for checking temperature and humidity variation in short period for equipments management purpose. RFT8100 can achieve the remote monitoring function by transmitting the measured data to DCS monitor centre or equipments management centre thru RS-485 port or Ethernet port. 2 EMC and safety standard IEC61000-4-2 (GB/T17626.2) IEC61000-4-8 (GB/T17626.8) IEC61000-4-4 (GB/T17626.4) IEC61010-1 (GB/T4793.1). Exterior Size:91*91*72mm 0.5KGS.
Humidification (heating)/dehumidification (cooling) output Switching display of temperature and humidity High/low limit alarm Sensor calibration Sensor error detection and on/off output control Minimum on/off duration time
Temperature and Humidity Controller XM-18 Function: 1. Digital displaying of temperature, humidity 2. Full automatic temperature controlling 3. Full automatic humidity controlling 4. Full automatically turning 5. Full automatically alarming 6.Full automatically ventilator 7. Back emergency system Main Technical Index: 1. Temperature display range: 0 ~ 99.9â?? 2. Temperature measurement accuracy: �± 0.1â?? 3. Humidity display range: 0-99% RH 4. Humidity control accuracy: �± 3% RH 5. Output path: 7 Road ( over-temperature, temperature control, insufficient temperature, egg-left turning, egg right-turning, humidity control, alarm ) 6. The maximum output load current: temperature control, insufficient temperature less = 8A/AC 220V, over-temperature,egg-left turning, egg right-turning, humidity control, alarm less = 1A /AC 220V 7. Number of egg-turning : Maximum record 999 times. 8. Cycle of egg-turning: from 0 to 999 minutes (factory set at 90 minutes) 9. Turn the eggs time: 0 to 999 seconds (factory set at 180 seconds) 10. Ventilation cycle : 0-999 minutes (factory set at 120 minutes) 11. Ventilation time: 0-999 seconds (Factory set at 30 seconds) 12. The measuring line length: 1.5 meters Working conditions: 1. Power Supply: AC 160V ~ 240V, 50Hz or AC 110V ( choose the one you need ) 2. Relative humidity: less than 85% 3. Ambient temperature: -10 ~ 60â??Digital display of temperature, humidity Fully automatic temperature controlling Fully automatic humidity controlling Automatic turning
BJ-S series Intelligent temperature and humidity controller with completed FUZZY algorithm provides very precise of temperature and humidity monitor. FUZZY algorithm control fan or heater to maintain sensible & latent capacity follows temperature and humidity curve by automatically. Display unit can show environment humidity as per configure by user. The user also can adjust environment condition very easily. Accept customerized control logic modify details please contact our sales team. FEATURES Digital thermostat with 2 control port for fan & heater 3 digital or 4 digital LED screen for temperature and humidity value Sensor length max 10meter (default 3meter) Minimal size 48*48mm panel mounting, optional Din-rail mounting rack
B series temperature and humidity controller with completed FUZZY algorithm control fan or heater to maintain sensible & latent capacity follows temperature curve by automatically. And have an independent humidity input can monitor the environment RH and output control signal. User can adjust temperature value very easily to use dial and a LED indicator to show the relay. FEATURES Electromechanical thermostat, max with 2 control port for fan & heater Dial pad setting temperature / humidity threshold Sensor length max 10meter (default 3meter) 48*48mm panel mounting size, optional Din-rail mounting rack
XM452 Temperature Humidity Controller for Incubator With Indicators Thermometer Hygrometer Automatic XM452 Temperature Humidity Controller for Incubator With Indicators Thermometer Hygrometer Automaticpower supply :DC 12V Temperature measurement range:- 40~120? Humidity range?0~100%RH Control precision?0.1? 0.1% RH Test probe?Integrated sensor output:10A delay Size:65*55*28mm temperature control: 1. Set the temperature + ?Normal display mode, long press the + key for 3 seconds, start temperature numerical flashing, press the + / - key setting values, wrong operation after 5 seconds, automatically return to detect temperature display 2. Set the temperature ?- Normal display mode, long press - button for 3 seconds, stop numerical flashing temperature, press the + / - key set value 3. Restore the factory Settings:- At the same time long press temperature, and humidity Set the start temperature:Long press the + key, start the flashing temperature, set start temperature by + / - key set Stop temperature:- long press - button, stop flashing temperature, set stop temperature by + / - key Humidity Settings: Set to start humidity: long-press the + key, start the humidity value flashing, set by + / - key launch humidity value Set stop humidity:- long press - to stop humidity value, set by + / - key to stopping the humidity value Fault code:- display LLL means the sensor fault display HHH mean Test temperature exceeds the range of measurement
Temperature Humidity Controller XM452 power supply: DC 12V Temperature measurement range:- 40~120? Humidity range?0~100%RH Control precision?0.1? 0.1% RH Test probe?Integrated sensor output:10A delay Size:65*55*28mm temperature control: 1. Set the temperature + ?Normal display mode, long-press the + key for 3 seconds, start temperature numerical flashing, press the + / - key setting values, wrong operation after 5 seconds, automatically return to detect temperature display 2. Set the temperature ?- Normal display mode, long press - button for 3 seconds, stop numerical flashing temperature, press the + / - key set value 3. Restore the factory Settings:- At the same time long press temperature, and humidity Set the start temperature:Long press the + key, start the flashing temperature, set start temperature by + / - key set Stop temperature:- long press - button, stop flashing temperature, set stop temperature by + / - key Humidity Settings: Set to start humidity: long-press the + key, start the humidity value flashing, set by + / - key launch humidity value Set stop humidity:- long press - to stop humidity value, set by + / - key to stopping the humidity value Fault code:- display LLL mean the sensor fault display HHH mean Test temperature exceeds the range of measurement
Enerna IoTech Cellular 4G LTE IoT RTU Temperature Humidity Alarm Controller. It can Be controlled by SMS mode or 4G Data Network Mode. the 4G switch Controller support wide applications, such as access control system, Pump motor controlling, smart light fan switch, generation room monitor Control Enerna IoTech Cellular 4G LTE IoT RTU Temperature Humidity Alarm Controller Temperature & Humidity Control function: If the Temperature(humidity) is less than (more than ) the tempeareture (humidity ) you set, the device will switch on/off automatically as you Required. for example: If you need the device to work automatically when the device less than ( more than ) a certain temperature /humidity, you Can use this function. Skype: iotech(at)foxmail.com Whatsapp: 0086-137-2827-9456 Wechat: 13728279456 Web: Enerna-IoTech.com Enerna IoTech Cellular 4G LTE IoT RTU Temperature Humidity Alarm Controller Function: 1. Remote Control, no distance limitation 2. Dial Control first relay, SMS control 4 relays 3. 4G Data network Remote Control Via App 4. with 4 relay output (10A/30VDC, 10A/250VAC) 5. Support Temperature/Humidity Control 6. Scheduled/Timing Control 7. Industrial class design, Aluminum alloy material Packing List: 1* Enerna IoTech Cellular 4G LTE IoT RTU Temperature Humidity Alarm Controller 1* User Manual
Pioneer in the technology of GSM sms alarm devices, legato possesses a team of expertise in engineering and programming of communication controllers. GSM sms alarm messenger has been a success worldwide during the past few years. It is widely installed in control and alarm systems for industrial monitoring, power plant, water supply network, geographical control and security. Temperature & humidity sms alert controller is dedicatedly developed for environmental monitoring and control. It sends sms alarm when temperature or humidity is higher/lower than user preset levels. More importantly, it provides the on/off control of equipments e.g. Air ventilation for maintenance in temperature/humidity range. Application is unlimited where temperature and humidity needs to be monitored on site and remotely.
Intelligent temperature & humidity controller with completed FUZZY algorithm provides very precise of temperature monitor. FUZZY algorithm control fan or heater to maintain sensible & latent capacity follows temperature/humidity curve by automatically. Display unit can show environment temperature and humidity as per configure by user. The user also can adjust environment condition very easily. Function & Feature ·DIN(48X48mm) Controller ·Indication and control accuracy 0.1, high measurement ·Heat/Cool control and PID control mode ·All settings except time maintained permanently in non-volatile memory until changed by user ·Built-in digital filter reduce interfere ·Self calibration technology, keep stabilization ·LED display show the data, prevent dazzle, highly visible display ·Simple 4-Button user interface ·Switching power supply and low consumption. ·Use large capacity relay