Enerna IoTech Cellular 4G LTE IoT RTU Temperature Humidity Alarm Controller. It can Be controlled by SMS mode or 4G Data Network Mode. the 4G switch Controller support wide applications, such as access control system, Pump motor controlling, smart light fan switch, generation room monitor Control
Enerna IoTech Cellular 4G LTE IoT RTU Temperature Humidity Alarm Controller Temperature & Humidity Control function: If the Temperature(humidity) is less than (more than ) the tempeareture (humidity ) you set, the device will switch on/off automatically as you Required. for example: If you need the device to work automatically when the device less than ( more than ) a certain temperature /humidity, you Can use this function.
Skype: iotech(at)foxmail.com
Whatsapp: 0086-137-2827-9456
Wechat: 13728279456
Web: Enerna-IoTech.com
Enerna IoTech Cellular 4G LTE IoT RTU Temperature Humidity Alarm Controller Function:
1. Remote Control, no distance limitation
2. Dial Control first relay, SMS control 4 relays
3. 4G Data network Remote Control Via App
4. with 4 relay output (10A/30VDC, 10A/250VAC)
5. Support Temperature/Humidity Control
6. Scheduled/Timing Control
7. Industrial class design, Aluminum alloy material
Packing List:
1* Enerna IoTech Cellular 4G LTE IoT RTU Temperature Humidity Alarm Controller
1* User Manual
XM452 Temperature Humidity Controller for Incubator With Indicators Thermometer Hygrometer Automatic XM452 Temperature Humidity Controller for Incubator With Indicators Thermometer Hygrometer Automaticpower supply :DC 12V Temperature measurement range:- 40~120? Humidity range?0~100%RH Control precision?0.1? 0.1% RH Test probe?Integrated sensor output:10A delay Size:65*55*28mm temperature control: 1. Set the temperature + ?Normal display mode, long press the + key for 3 seconds, start temperature numerical flashing, press the + / - key setting values, wrong operation after 5 seconds, automatically return to detect temperature display 2. Set the temperature ?- Normal display mode, long press - button for 3 seconds, stop numerical flashing temperature, press the + / - key set value 3. Restore the factory Settings:- At the same time long press temperature, and humidity Set the start temperature:Long press the + key, start the flashing temperature, set start temperature by + / - key set Stop temperature:- long press - button, stop flashing temperature, set stop temperature by + / - key Humidity Settings: Set to start humidity: long-press the + key, start the humidity value flashing, set by + / - key launch humidity value Set stop humidity:- long press - to stop humidity value, set by + / - key to stopping the humidity value Fault code:- display LLL means the sensor fault display HHH mean Test temperature exceeds the range of measurement
Temperature Humidity Controller XM452 power supply: DC 12V Temperature measurement range:- 40~120? Humidity range?0~100%RH Control precision?0.1? 0.1% RH Test probe?Integrated sensor output:10A delay Size:65*55*28mm temperature control: 1. Set the temperature + ?Normal display mode, long-press the + key for 3 seconds, start temperature numerical flashing, press the + / - key setting values, wrong operation after 5 seconds, automatically return to detect temperature display 2. Set the temperature ?- Normal display mode, long press - button for 3 seconds, stop numerical flashing temperature, press the + / - key set value 3. Restore the factory Settings:- At the same time long press temperature, and humidity Set the start temperature:Long press the + key, start the flashing temperature, set start temperature by + / - key set Stop temperature:- long press - button, stop flashing temperature, set stop temperature by + / - key Humidity Settings: Set to start humidity: long-press the + key, start the humidity value flashing, set by + / - key launch humidity value Set stop humidity:- long press - to stop humidity value, set by + / - key to stopping the humidity value Fault code:- display LLL mean the sensor fault display HHH mean Test temperature exceeds the range of measurement
1 RFT8100 wireless temperature and humidity detection system is composed by wireless temperature detection probes, humidity detection probes and display terminals. Adopting the advanced wireless temperature detection technology, RFT8100 transmits and displays the real time value detected from the local detection probes for the purpose of inspecting temperature and humidity on-site routinely. The alarm relay sends out signal when the temperature and humidity data exceeds or lowers the setting alarm value, and the alarm points can be found quickly by checking the alarm information. RFT8100 also provides curve diagram for checking temperature and humidity variation in short period for equipments management purpose. RFT8100 can achieve the remote monitoring function by transmitting the measured data to DCS monitor centre or equipments management centre thru RS-485 port or Ethernet port. 2 EMC and safety standard IEC61000-4-2 (GB/T17626.2) IEC61000-4-8 (GB/T17626.8) IEC61000-4-4 (GB/T17626.4) IEC61010-1 (GB/T4793.1). Exterior Size:91*91*72mm 0.5KGS.
Humidification (heating)/dehumidification (cooling) output Switching display of temperature and humidity High/low limit alarm Sensor calibration Sensor error detection and on/off output control Minimum on/off duration time
IoT based Temperature-Humidity Device: 1. Detects Temperature & Humidity and Inform to clients using SMS Message, Missed Calls 2. Threshold Levels can be set through APP Control 3. TCP/IP Protocal Transfer to Server support can be configured 4. IoT support through MQTT protocal is supported 5. GSM alert and control 6. Telegram Alert 7. Telegram Group Alert 8. Whatsapp Alert
IoT based Temperature-Humidity Device: 1. Detects Temperature & Humidity and Inform to clients using SMS Message, Missed Calls 2. Threshold Levels can be set through APP Control 3. TCP/IP Protocal Transfer to Server support can be configured 4. IoT support through MQTT protocal is supported 5. GSM alert and control 6. Telegram Alert 7. Telegram Group Alert 8. Whatsapp Alert
Scope Standards: gb/t 2361 and astm d1748 It is widely used in pharmaceutical, textile, food processing, bio-engineering experiments and industrial products of the temperature and humidity testing. Features 1. Mirror stainless steel liner, surrounded is designed and made as per semicircular easy to clean, inside adjustable shelf spacing; 2. The use of double doors, insulation performance is good. Interior doors is use full glass door, open the outer door, observing the situation does not affect the internal temperature inside; 3. High-precision, high-capacity humidity generator. Ensure humidity control occurs, high precision, small fluctuations; 4. The original french “taikang” closed compressor, configure delay start. High and low pressure multiple protection. Technical parameters 1. Dimensions: mm (depth × width × height) in order to prevail in kind 2. Room size: 400 × 400 × 500mm (depth × width × height) 3. Measuring range: 10 °c~ 85 °c (determined according to customer requirements) 4. The temperature fluctuation: ± 1 °c (no load) 5. The temperature uniformity: ± 2 °c (no load) 6. Humidity control range: 40 ~ 95% rh (no load) 7. Heating method rate: 3 ~ 4 °c/ min (no load) 8. Humidity fluctuation: ± 5% rh 9. The noise (db): 65 10. Power supply: 220v ± 10%, 50hz ± 1 ground wire, protective earth resistance of less than 4o 11. The total power: 1.8kw
Temperature and Humidity Controller XM-18 Function: 1. Digital displaying of temperature, humidity 2. Full automatic temperature controlling 3. Full automatic humidity controlling 4. Full automatically turning 5. Full automatically alarming 6.Full automatically ventilator 7. Back emergency system Main Technical Index: 1. Temperature display range: 0 ~ 99.9â?? 2. Temperature measurement accuracy: �± 0.1â?? 3. Humidity display range: 0-99% RH 4. Humidity control accuracy: �± 3% RH 5. Output path: 7 Road ( over-temperature, temperature control, insufficient temperature, egg-left turning, egg right-turning, humidity control, alarm ) 6. The maximum output load current: temperature control, insufficient temperature less = 8A/AC 220V, over-temperature,egg-left turning, egg right-turning, humidity control, alarm less = 1A /AC 220V 7. Number of egg-turning : Maximum record 999 times. 8. Cycle of egg-turning: from 0 to 999 minutes (factory set at 90 minutes) 9. Turn the eggs time: 0 to 999 seconds (factory set at 180 seconds) 10. Ventilation cycle : 0-999 minutes (factory set at 120 minutes) 11. Ventilation time: 0-999 seconds (Factory set at 30 seconds) 12. The measuring line length: 1.5 meters Working conditions: 1. Power Supply: AC 160V ~ 240V, 50Hz or AC 110V ( choose the one you need ) 2. Relative humidity: less than 85% 3. Ambient temperature: -10 ~ 60â??Digital display of temperature, humidity Fully automatic temperature controlling Fully automatic humidity controlling Automatic turning
BJ-S series Intelligent temperature and humidity controller with completed FUZZY algorithm provides very precise of temperature and humidity monitor. FUZZY algorithm control fan or heater to maintain sensible & latent capacity follows temperature and humidity curve by automatically. Display unit can show environment humidity as per configure by user. The user also can adjust environment condition very easily. Accept customerized control logic modify details please contact our sales team. FEATURES Digital thermostat with 2 control port for fan & heater 3 digital or 4 digital LED screen for temperature and humidity value Sensor length max 10meter (default 3meter) Minimal size 48*48mm panel mounting, optional Din-rail mounting rack