Dry contact Explosion- proof UV flame detector A705/UV Fire alarm relay output Fault relay output EXdâ?¡CT6
Product function and composition
A705/UV can be applied to the need to monitor the implementation of the fire place, quickly found that the fire may cause the burning flame, issued in a timely manner
Fire alarm.
A705/UV using the cold cathode ultraviolet photoelectric tube to convert the flame combustion parameters into electric pulse signal, then the signal input is calculated.
Chip for operation and processing, with the UVdetecter@anysafe dedicated intelligent control software, can be issued in a timely manner to the fire alarm.
A705/UV uses the aluminum die-casting flameproof shell, has good protective properties and explosion-proof, corrosion resistance, aging resistance, can work for a long time
Indoor, outdoor, and various special industrial locations
Sensor sharp probe AE-S708/4 and AE-S708/5 infrared pyroelectric sensor
Optical window white gems (Al2O3)
housing
L material: aluminum alloy
L molding process: Die Casting
L coating process: surface electrostatic powder coating, internal metal passivation treatment.
The weight is less than 1kg
Explosion proof and protection l anti explosion: EXd II CT6
L protection: IP66
v 4-wire UV Flame Detector with Relay output
General Description
The device is an Ultraviolet-only flame detector designed
to detect fires and provide alarm outputs directly from the
detector while maintaining false alarm immunity. It
detects in the ultraviolet (UV) spectral range for
optimized speed of response.
It is fast and capable to detecting the ultraviolet (UV) rays
emitted by a burning substance and is used in high hazard
applications such as petrochemical plants, munitions
factories and other areas where flammable or explosive
liquids or solids are handled or stored.
The flame sensor adopts an ultraviolet photosensitive
tube, with qualities of highly sensitive, reliable,
dust-resistant, corrosion proof and moisture-resistant,
therefore is not sensitive in sunlight, dust, oil, tolerance of
fume, and humidity. Set in a standard calibration to detect
a flames at a distance of 25 meters, which flame created
by 2Kg ethanol in a Container of Base 33cmX33cm,
Height 5cm.
Specifications
Operating Voltage Range: 12 to 28 VDC Volts
Standby Current: â?¤10 mA @ 24 VDC
Alarm Current â?¤40 mA @ 24 VDC
Spectrum: 180~290nm
Detection Angle: 120 degree
Detection Sensitivity: Grade I, 25m@flame (Container 33cmX33cm,Height 5cm with 2Kg ethanol )
Relay Contact Load: 1A@DC24V
Normal Status: LED blinking in 5 seconds interval
Alarm Status: LED lit steady
Protection rating: IP 21
Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range: -20°C to 55°C
Height: 45 mm installed in Base
Diameter: 103 mm
Weight: 153g
Optical Beam Smoke Reflective Beam Detector with Relay Output
General Descriptions
Conventional Reflective Beam Detector (hereinafter called the detector) is a non-addressable reflective infrared beam smoke detector is applicable to historical buildings, warehouses, large storages, shopping malls, leisure centers, exhibition halls, hotel lobbies, printing houses, clothing factories, museums and prisons etc, as well as places where slight smoke particles exist.
Features
(1) Wide operating voltage range, big monitoring areas.
(2) Combination of the emitting and receiving part makes mounting easy and optical pathway accurate.
(3) Built-in microprocessor enables intelligent judgment of fire alarm and fault.
(4) The detector can calibrate automatically, which ensures that one person complete adjustment in short time. Itâ??s also convenient to operate.
(5) Self-diagnosis function can monitor the inner fault.
(6) Automatic compensation for factors weakening received signals, such as dust contamination, positional excursion and ageing transmitter.
(7) It has passive output contacts for fire alarm and fault.
(8) Two sensitivity levels can be set in field.
(9) The detectorâ??s optical pathway is designed with strong anti-interference ability.
(10) SMT processing technology.
(11) Attractive and decent appearance.
Conventional Reflective Optical Beam Smoke detector Beam Detector Beam Alarm Sensor with Relay Output
Introduction
The Conventional Reflective Beam Detector has built in Laser beam pointing and Digital guide display for real
user friendly alignment method. The Laser beam pointing accurately point the exact location where to mount
mirror and with additional digital guide display allows to monitor and guide on the actual light intensity between
the mirror and detector which cannot be seen by our naked eye making it more easy and convenient in
alignment commissioning.
The beam detector has four adjustable operational range of between 8 to 20, 40, 70 and 100 meters beside
with three adjustable sensitivity setting ranges from 2.6dB to 4.8dB to meet the specific environmental
requirement. The detector works on the principle of reflective infrared beam obscuration. Used in conjunction
with a reflectors, it will notify the fire alarm panel when the infrared beam is obscured by smoke. Secure and
quick communication through the onboard processor enables the detector to make its own decision and drift
compensation resulting in greater automation.
The detector is ideal for use high ceiling and wide areas such as warehouses, large storages, shopping malls,
leisure centres, exhibition halls, hotel lobbies, printing houses, garment factories, museums and prisons, as well
as places where slight smoke particles or corrosive gas exist.
Feature and Benefits
1. Manufacture in compliance with EN54-12
2. Hassle free alignment, built with digital guide display and laser beam pointing
3. Employ single-ended design through reflective mirror.
4. Four ranges wide monitoring from 8-100 meters via encoder
5. Three users programing sensitivity adjustment
6. Built-in microprocessor
7. Self-diagnosis function can monitor for internal faults
8. Automatic compensation for factors weakening received signals, such as dust contamination, positional
movement and ageing of the transmitter
9. Fire and Fault interfacing relays
10. Attractive and pleasing appearance
11. Real User friendly alignment method
Key specifications/special features
Power source: 9 v battery (included).
Audio alarm: & g e; 85 db /3 m
Temperature range: 0 to 40 degree
Humidity range: 5%-95% relative humidity(rh)
Sensor: photoelectric
Size: diameter 105 mm in diameter x59 mm depth
Interconnects: no
Easy to install with mounting base included
Suitable for any room
Low battery signal
Test button for simple testing
100pcs in a carton
2zone MINI Conventional Fire Alarm Control Panel Fire Alarm Host/Master Panel /Slave Panel
Product Features
1. 2 conventional input zones.
2. 1 notification appliance circuits (NAC) with built-in synchronization forANSI 3.41and Gentex.
3. The panel comes with a 2 amp power supply.
4.Dedicated alarm and trouble relays.
5.1 RS485 can be able to connect the other panel.
6. Housed in a 205mm W x 258mm H x 81mm D metal enclosure.
7. Enclosure supports two 12V, 4Ah backup batteries.
8.The panel can be used independently or connect by RS 485.
Specifications
Primary AC 120VAC 50/60 Hz Power supply rating
240VAC 50/60 Hz
Power supply rating 2 Amps @ 24VDC
Maximum Battery Charging Current 0.98 Amps @ 26VDC
Initiating Device Circuits 2 Zones Alarm Zone 2
Normal Initiating Operating Voltage 23VDC, Maximum 26VDC, regulated
Normal Quiescent Current (normal status)
Dry contact Ex Double infrared flame detector relay output EXdIICT6
Dry contact Explosion proof Double infrared flame detector Fire alarm relay output Fault relay output IR2 EXdIICT6
Product function and composition
A705/IR2 can be applied to the need to monitor the implementation of the fire place, quickly found that the fire may cause the burning flame, issued in a timely manner
Fire alarm.
A705/IR2 is converted to electrical si gnal by two infrared pyroelectric sensors which work in different bands.
Signal input industrial computing chip for comparison, operation and processing, with the detecter&anysafe II Ir dedicated intelligent control software, you can Send out a fire alarm in time.
A705/IR2 uses the aluminum die-casting flameproof shell, has good protective properties and explosion-proof, corrosion resistance, aging resistance, can work for a long time
In the indoor, outdoor and all kinds of special industrial places.
Sensor sharp probe AE-S708/4 and AE-S708/5 infrared pyroelectric sensor
Optical window ï¼?white gems (Al2O3)
housing
L material: aluminum alloy
L molding process: Die Casting
L coating process: surface electrostatic powder coating, internal metal passivation treatment.
The weight is less than 1kg
Explosion proof and protection l anti explosion: EXd II CT6
L protection: IP66
2-wire Conventional Heat Detector Heat Alarm Sensor
The device is intelligent sensors that utilize a state-of-the-art thermistor sensing circuit for fast response.
Features and Benefits
1.Compatible with all the conventional fire alarm
control panel
2.Unpolarized wire input
3. Wide range of operating voltages
4. High precision electronic thermistor
5. Built in microprocessor intelligent software
6. wo LEDs blink standby , provide 360° visibility
7. Insect-resistant s creening
8. Twist-on mounting base with tamper lock
9. Remote Indicator LED can be connected.
Specifications
Installation Temperatures: 14°F to 122°F (-10°C to50°C)
Operating Humidity Range: 10% to 93% Relative Humidity Non-condensing
Operating Voltage Range: 16 to 32VDC Volts Non-polarized
Standby Current: 40µA @ 24 VDC
Maximum Alarm Current (LED on: ) â?¤30mA @ 24 VDC
Fixed Temperature Rating: 135°F (57°C)
Height: 2.2� (55 mm) installed in Base
Diameter: 4.0� (103 mm)
Weight: 5.5 oz. (155 g)
2-wire DC powered Conventional Manual Call Point Push Button
The conventional manual call point designed for conventional fire alarm system for reporting fire or emergency
condition by its button latches. The call point has one 300 ohm resistor is used on the PCB board between
Zone+ and Zone- or one relay contact (NO, COM, NC ) output when the button is pressed.
Specifications:
Operating Voltage Range: 9ï½?32VDC Volts
Nominal Operating Resistance: 300Ω
Relay Contact Ratings: 2A/30VDC
Operating Humidity Range: 95% RH, Non-condensing
Operating Temperature Range: -10C to 50C (14F to 122F)
Dimensions: W89mm ,H93mm, D26mm
Base Dimensions: W87mm ,H87mm, D31.5mm
Weight: Net Weight 125g (with base)
Colour/Case Material: Red/ ABS
Conventional fire alarm smoke detector smoke probe sensor
This device is photoeletronic detector uses a state-of-the-art optical sensing chamber.
This smoke detector is compatible with all conventional fire alarm control panel
Dual leds, two leds blink standby, provide 360dgree visibility
With unique optical sensing chamber, engineered to sense smoke by a wide range of combustion sources.
Unpolarized wire input to prevent the likelihood of wiring errors
Specifications
Operating voltage range: 9 to 28vdc volts non-polarized
Standby current: 60µa @ 24 vdc
Maximum alarm current (led on: ) 30ma @ 24 vdc
Operating humidity range: 10% to 93% relative humidity, non-condensing
Operating temperature range: 14°f to 122°f (-10°c to50°c)
Adjustable sensitivity: 0.15ï½?0.3db/m
Height: 2.2ë� (55 mm) installed in base
Diameter: 4.0ë� (103 mm)
Weight: 5.5 oz. (155 g)
2-wire DC24V Conventional Manual Call Point Broken Glass Button Push Button
The conventional manual call point designed for
conventional fire alarm system for reporting fire or
emergency condition by pull down the plate. The
manual call point can be reset by a special key
without breaking the glass.
Features
1. Compatible with all the conventional fire alarm control panel
2. Can be reset by key without use a new glass
3. 470 Ohm resistance
4. Easy surface mounting Base included
Specifications
Operating Voltage Range: 9 to 28VDC Volts
Alarm Resistance 470ohm/1W
Operating Humidity Range: 10% to 93% Relative Humidity, Non-condensing
Operating Temperature Range: -10C to 50C (14F to 122F)
Dimensions: Length 140mm, Width 105mm, Depth 45mm
Weight: Net Weight 220g
2-wire Conventional Sound Strobe Fire alarm Sound Siren
The Sounder strobe is a kind of audible and visual alarm
device installed in field, which can be activated by fire
alarm control panel in fire control center or by manual
call point installed in field. After activated, it will
generate strong audible/audible and visual alarm signal to
warn people in field.
Features
1. Compatible with all the conventional fire alarm control panel
2. Long light life up to 40000 flahsed
3. High sound level up to 100dB
Specifications
Working voltage: 16VDC to 30VDC.
Alarm Current: â?¤ 50mA.
Ambient temperature: -10â?? to +55â??.
Ambient humidity: â?¤95%RH.
Sound level of alarm : â?¥100dB.
Flash Intensity: â?¥75CD
Flash Period: 40000times
Dimensions: 133mmÃ?115mmÃ?50mm
L Ã?WÃ?D(With base)
Weight: 141g
Conventional Fire Alarm Control Panel /Security Alarm Host/ Master Control Panel
Products Features
4,8,16 Class B Initiating Device Circuits (IDCs)
All zones accept conventional detectors and any normally open contact device
Four Class B Notification Appliance Circuits (NACs)
One Form-A Alarm Relay
One Form-A Trouble Relay
One Form-A Supervisory Relay
3.0 amps of system power
Max 30 conventional detectors
in one zone.
Auto/Manual mode setting enable walk test.
Each Zone can be disabled,
Sound output can be disabled.
Manual active sound output enabled.
Able to report short and broken circuit of detection zones.
Designed with standby batteries and space provision for two sealed lead-acid batteries.
Testing and disable functions.
Can connect max 32 repeater panels by RS485 communication port
Dimensions : 14.57 " (37 cm) long X 17.32" (44 cm) high X 3.94"(10cm).
Weight: 6.6kg (without battery).
Specifications
AC Power
90-270 VAC, 50 Hz, 2.3 amps
Wire size: minimum #14 AWG (2.0 mm 2 ) with 600V insulation
Battery (lead acid only)
Maximum Charging Circuit: Normal Flat Charge27.6V @ 0.8 amp
Maximum Charger Capacity: 18 Amp Hour batter
Sound Output Device Circuits
General Alarm Zones 1 through 16
Operation: All zones Class B
Normal Operating Voltage: Nominal 24 VDC (ripple = 100 mV maximum)
Alarm Current: 15 mA threshold
Short Circuit Current: 42 mA maximum
Maximum Loop Resistance: 100 ohms
End-of-Line Resistor: 4.7K, ½ watt
Detector Loop Current is sufficient to ensure operation of two alarmed detectors per zone
Standby Current: 7.26 mA
Three Relays Output
Relay contact rating: 2.0 amps @ 30 VDC (resistive), 2.0 amps @ 30 VAC (resistive)
Nonresettable 24 VDC Power
Maximum ripple voltage: 10 mV RMS Operating Voltage nominal 24 volts
Total DC current available from this output is up to 500 mA
Recommended maximum Standby current is 150 mA
24VDC Electric Fire Bell
The bell remains the most commonly used alarm for fire evacuation system, for wall applications, indoors.
They are designed to be used in 24 volt DC systems.
Wiring
The system designer must make sure that the total current drawn by the devices on the loop does not exceed the
current capability of the panel supply, and that the last device on the circuit is operated within its rated voltage.
When calculating the voltage available to the last device, it is necessary to consider the voltage drop due to the
resistance of the wire. The thicker the wire, the smaller the voltage drops. Wire resistance tables can be obtained from
electrical handbooks.
Specifications
Voltage ranges: 20vdc to 28vdc (Nonp
olarity)
Power and current consumption: 1W, 38ma@24vdc(maximum)
Number of standard: EN54-3
Sound levelï¼?80dBï¼?Aï¼?@1M (minimum)
Service Use: Fire alarm, general signaling, burglar alarm
Environment type: TypeA(indoor)
Input terminal Wire Gauge: 0.28 mm 2 to 1.5 mm 2
Operating Temp.: -10â?? to +55â??
Operating Humidity Range: 10% to 93% Relative Humidity ( Non-condensing)
Material of cover:Aluminum
Dimension: 150mmÃ?50mmï¼?D*H) (Without bracket)
Weight: Net Weight 342g, Gross Weight 395g