1.Product Profile QAM8300-1M power quality analyzer is an integrated monitoring, analyzing and controlling device that offers electrical parameter metering, harmonics metering and analysis, waveform sampling, measurement of Voltage swell, dip, interrupt, Voltage unbalanced ratio, fault record, event record, data record. QAM8300-1M can monitor and detect if the power quality fulfills IEC and EN standard. With its powerful I/O functions with exterior device, QAM8300-1M can perform harmonic control, PF adjustment, and demand monitoring functions. QAM8300-1M fulfils all the important requirements of IEC 61000-4-30 Class A standard. QAM8300-1M can work with our power quality monitoring and management software to provide energy management solutions for enterprises. With its strong networking capability, QAM8300-1M can display and record all the data records on the interactive trend chart. A data report can be formed periodically. The report can be used for fault analysis, statistics, real time monitoring purpose. QAM8300-1M fulfills IEC61000-4-30 A: 2003,IEC61000-4-15:2003,IEC61000-4-7:2002,EN50160,2004 etc standards. 2.Measurement Accuracy U, I: 0.1% U, I peak value, peak factor, flicker: 0.5% 3 phase Voltage unbalanced ratio: 0.2% 3 phase Current unbalanced ratio: 0.5% Frequency: 0 .002Hz Power factor: 0 .002 Power: 0.2% Energy: Active energy 0.2% IEC60687:1992(GB/T17883-1999) Reactive energy 0.2% IEC61268(1995) (GB/T17882-1999) Harmonics: IEC61000-4-30 class A Interharmonics: IEC 61000-4-30 class A Harmonic distortion rate: 2.5% 3.EMC and safety test EN61326-1 EN61000-4-2/3/4/5/12 IEC/EN61010-2001.
FEATURES 3s statistical interval, continuously record 168h Support multi-brand current transformer Up to 32G data storage space Record up to 461 power energy parameters simultaneously Up to 10000 screenshots saved Support periodic recording function Up to 3.9M/s USB high-speed transfer Recording wave FUNCTIONS Energy loss calculator: classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint true system energy losses in dollars (other local currencies available). Power inverter efficiency: simultaneously measure AC output power for power electronics systems. Power wave data capture: GF438II analyzers capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.). Waveform capture: GF438II capture 50/60 cycles (50/60Hz) of each event that is detected in all modes, without set-up Automatic transient GF438II analyzers capture 200 kHz waveform data on all phases simultaneously up to 1000V. Fully class-A compliant: GF438II analyzers conduct tests according to the stringent international IEC 61000-4-30 class-A standard. Mains signaling: GF438II analyzer measure interference from ripple control signals at specific frequencies. Troubleshoot: analyze the trends using the cursors and zoom tools. Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance. Measure all three phases and neutral: with included four flexible current probes with enhanced thin flex designed to fit into the tightest places. Automatic trending: every measurement is always automatically recorded, without any set-up. System-monitor: ten power quality parameters on one screen according to EN50160 power quality standard Logger function: configure for any test condition with memory for up to 600 parameters at user defined intervals. View graphs and generate reports: with included analysis software. Battery life: up to 5 hours operating time per charge on Li-ion battery pack.
Product description Electrical equipments in modern industrial, commercial and residential users are more sensitive to power quality, and have a higher requirement of quality of power supply. Currently, harmonics,electromagnetic interference, power factor reduction have been tied to the three hazard of the power system. When it is interfered or contaminated, grid power quality can t reach the national standards, so it has to be targeted on the grid power quality improvement. To understand the actual situation of power quality, you must have the appropriate equipment to test and analysis the actual situation. Counter the domestic condition, our company developed the professional power quality analysis instrument, which is suitable for the country. 3 phase handheld power quality analyzer Technical index 1. Input characteristics
FEATURES Ultra-compact design, handheld, small size, light weight. The usage of multi-channel power supply, AC power supply can also be rechargeable battery-powered machine. High accuracy instrument, good stability and wide range of voltage monitoring 0-1200V, current 0-500A. It can be divided into direct current clamp measurements and precision measurements. It can measure three phase voltage, current, active power, reactive power, power factor, frequency, phase, etc. Showing the AC waveform, vector diagram and determining the 3P3W connection errors. It can measure harmonics ration from 2nd to 64th and the harmonic analysis. The measured data can record, query and upload print. Instrument calibration by using software to facilitate the correction instrument variation. FUNCTIONS Measuring energy consumption values: the precise timing measurements of electrical equipment for short-term energy consumption; energy resolution; milli-watts; time resolution; milli-second; they are difficult to available for common instrument of power. The functions are used by pumping, cranes, air conditioning and other equipment in a work cycle connected power consumption. The value of the measurement process: it can be recorded and tested continuously of voltage, current, active power, reactive power and other electrical parameter values and curves in a dynamic process and graphically display. To measure the instantaneous values - including the exchange parameters: U, I, P, Q, PF, phase angle, frequency, harmonics, etc. Measuring harmonics: measure/display voltage and current waveforms and harmonic bar graph. Calibrator meter: load calibration of various single phase and three phase energy meters. Vector analysis: based on the voltage, current and phase error, display vector graphics.
Power Quality Analyzer SA2100 Power Quality Analyzer Fast Sampling, portable and handheld Brief Introduction SA2100 Power Quality Analyzer is the professional potable device to measure and analyze the power system quality, supply the harmonics analysis and power quality data analysis, also provide big memory for the data storage, which is used to make the long term logger measuring to power system. The PC software can simply upload the data to PC for full analysis. Main Features Waveform real-time display(4 voltages/4 currents) Half-period RMS measurement (voltage and current) Measurement of TRMS currents up to 5000A (sensor dependent) Measurement, calculation and display of harmonics and interharmonics can be up to 50 times. Transient capture Active power, reactive power, apparent power and energy, shift power factor and true power factor Three-phase unbalance (voltage and current) Flicker Inrush current Detection and record of Dips& Swells, Voltage Rapid Change, Interruption. Detect according to EN50160 or grid with user-defined limit Data storage and screenshots (can be replayed or output to a PC) Through the LAN interface PC can keep real-time remote communication with the Analyzer, operate the Analyzer and read back measurement data Built-in 8G memory card
Power Quality Analyzer Brief Introduction SA2100 Power Quality Analyzer is the professional potable device to measure and analyze the power system quality, supply the harmonics analysis and power quality data analysis, also provide big memory for the data storage, which is used to make the long term logger measuring to power system. The PC software can simply upload the data to PC for full analysis. Main Features Waveform real-time display(4 voltages/4 currents) Half-period RMS measurement (voltage and current) Measurement of TRMS currents up to 5000A (sensor dependent) Measurement, calculation and display of harmonics and interharmonics can be up to 50 times. Power Quality Analyzer Transient capture Active power, reactive power, apparent power and energy, shift power factor and true power factor Three-phase unbalance (voltage and current) Flicker Inrush current Detection and record of Dips& Swells, Voltage Rapid Change, Interruption. Detect according to EN50160 or grid with user-defined limit Data storage and screenshots (can be replayed or output to a PC) Through the LAN interface PC can keep real-time remote communication with the Analyzer, operate the Analyzer and read back measurement data Built-in 8G memory card
Product Introduction SMG7000 Handheld Power Quality Analyzer Input Characteristics 1. Voltage measuring range: 0~400V auto. 2. Current measurement range 3. Clamp transformers (three): 5A/25A (standard) 100A/500A (optional) 400A/2000A (optional) 4. Phase angle measurement range: 0~359.99 �°. 5. Frequency range: 45~55Hz. 6. Voltage number of channels: three channels (UA UB and UC). 7. Current number of channels: three channels (IA IB IC). 8.Maximum number of harmonic analysis: 63 times. 9. Intervals of 1 minute maximum storage period: 18 months
SMG7000 Handheld Power Quality Analyzer Input Characteristics 1. Voltage measuring range: 0~400V auto. 2. Current measurement range 3. Clamp transformers (three): 5A/25A (standard) 100A/500A (optional) 400A/2000A (optional) 4. Phase angle measurement range: 0~359.99 �°. 5. Frequency range: 45~55Hz. 6. Voltage number of channels: three channels (UA UB and UC). 7. Current number of channels: three channels (IA IB IC). 8.Maximum number of harmonic analysis: 63 times. 9. Intervals of 1 minute maximum storage period: 18 months
Product Parameters Alternating current source SMG7000 Handheld Power Quality Analyzer Accuracy 1. Electric parameter measurement part: Voltage: ± 0.2% Frequency: ± 0.01Hz Current power: ± 0.5% Phase: ± 0.2 2. Power quality parts: Fundamental voltage permissible error 0.5%F.S. Fundamental current allowable error:1%F.S. 3. Fundamental error of measurement of phase differencebetween voltage and current: 0.2 4. Harmonic voltage rate measurement error: 0.1% 5. Contain measurement error of harmonic current: 0.2% 6. Three-phase voltage unbalance error: 0.2% 7. Voltage deviation error: 0.2% 8. Voltage tolerance: 0.2% working temperature:-10 ~ + 40 power supply: AC220V frequency 45Hz-55Hz power consumption: 3VA battery operating time: less than 10 hours insulation: 1) input voltage and current on the chassis of theinsulation resistance: 100M Max. 2) power input terminals for shell under industrialfrequency 1.5KV (RMS) a 1-minute experiment. 9. Volume: 320mmx240mmx130mm 10. Weight: 2.0Kg
Three-Phase Power Quality Analyzer (BJMDZ-3540) is a high-accuracy test instrument with harmonic content of voltage fluctuation and flicker and phase imbalance of power quality problems.
Features Troubleshoot real-time: Analyze the trends using the cursors and zoom tools-even while background recording continues. Automatic Transient Mode: Capture 200 kHz waveform data on all phases simultaneously up to 6 kV Measure all three phases and neutral: With included four current probes System-Monitor: Up to ten power quality parameters on one screen according to EN50160 power quality standard View graphs and generate reports: With included analysis software Logger function: Configure for any test condition with memory for over 400 parameters at user defined intervals. Mains signaling: Measure interference from ripple control signals at specific frequencies Inrush mode: For troubleshooting nuisance circuit breaker tripping. AutoTrend: Every measurement you see is always automatically recorded, without any setup. Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard. Battery Life: Seven hours operating time per charge on NiMH battery pack High safety rating: 600 V CAT IV/1000 V CAT III rated for use at the service entrance • Comparing to online power quality analyzer, E6000 handheld type with small size, light weight, easy for the engineer to carry and carry out to survey work whenever and wherever. • Easy to wiring • It can operate directly to the line under test under the circumstances that the Power Grid without interrupt. • Multi-range current switching • based on actual demand, the different range of current clamp can be replaced to improve measurement accuracy. Applications Frontline troubleshooting - quickly diagnose problems on-screen to get your operation back online Predictive maintenance - detect and prevent power quality issues before they cause downtime Quality of service compliance - validate incoming power quality at the service entrance Long-term analysis - uncover hard-to-find or intermittent issues Load studies - verify electrical system capacity before adding loads Energy assessments - quantify energy consumption before and after improvements to justify energy saving devices. Specifications Measurement Items Be measured Type of measurement RMS Voltage Voltage RMS Current Current Frequency Deviation Frequency Three-phase Unblanced Voltage, Current Voltage fluctuations Voltage Flicker Voltage Harmonics and inter-harmonics, higher harmonic Voltage, current Power Active, reactive, apparent power factor Event log Transient pulse, the voltage rise, voltage sags, voltage interruption, the impact of current, frequency of abnormal Input parameter Measuring circuit 1P2W, 1P3W, 3P3W, 3P4W The fundamental frequency of the measuring circuit 50Hz/60Hz Number of input channels Voltage, current, 4 Measurement range Voltage Measurement Range: Nominal value: 100V, 230V, 400V, maximum 1000V Current measurement range: Depending on the current clamp, current clamp the output voltage signal, the maximum voltage: 10V peak Environmental security parameters Use of the environment 0 ° C to +45 ° C, humidity 90rh% Storage environment -20 ° C to +50 ° C, 95RH% humidity (non-condensing) Power input voltage +100VAC ~ +240VAC Electromagnetic Compatibility Level 3: GB / T 17626.2-2006 Electrostatic Discharge Immunity Level 3: GB / T 17626.3-2006 RF electromagnetic radiation the Immunity Level 3: GB / T 17626.4-2008 electrical fast transient burst immunity Level3: GB / T 17626.5-2008 surge (impact) Immunity Level 3: GB / T 17626.8-2006 frequency magnetic field immunity Level 3: GB / T 17626.9-1998 Pulse magnetic field immunity Level 3: GB / T 17626.12 -1998 Oscillatory waves immunity Environmental reliability GB/T 2423.1-2008 low temperature GB/T 2423.2-2008 high temperature GB/T 2423.4-2008 alternating hot and humid GB/T 2423.5-1995 impact GB/T 2423.10-2008 vibration GB/T 2423.22-2002 temperature changes Dustproof, waterproof IP20(GB 4208-93/IEC 529:1989) Security 500V/10M,2KV:GB/T 15479-1995 External interface parameters USB Device 1 The upload power quality data TF card to expand storage 1 Built-in capacity Optional, up to 8G Battery 1 4500mAh Ni-MH battery LCD 1 26 million color 5.6-inch LCD screen with a resolution of 640 * 480 Voltage and current measurement interface 8 Test voltage and current input port Frequency Measurement method 10 waveform (50Hz) the calculated frequency Display Display of a channel frequency value Measuring range / resolution 50.0000Hz/0.0001Hz Measurement bandwidth 42.5000~57.5000Hz Measurement accuracy ±0.001Hz 1/2 rms voltage 1/2 rms, current Measurement method Once every two cycle operations, a waveform operations per cycle to take 1/2 cycle Sampling Frequency 200K Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01,Based on the use of current clamp Measurement accuracy 0.1% of the nominal voltage RMS voltage Measurement method 10 waveforms (50Hz) the operator Display Per channel RMS voltage Sampling Frequency 200K Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01 Measurement accuracy 0.1% of the nominal voltage RMS voltage Measurement method 10 waveforms (50Hz) the operator Display Current per channel RMS Sampling Frequency 200K Measuring range / resolution Based on the use of current clamp Measurement accuracy 0.1% of the nominal voltage Harmonic voltage, harmonic current Measurement method According to IEC61000-4-7, the magnitude of the analysis window 10 cycles Window points Every 10 cycles of 5120 points Display Histograms, tables Sampling Frequency 200KHz Number of measurements 0~50 Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01 Measurement accuracy voltage harmonics greater than 1% of the nominal value: Error is less than 1% rdg voltage harmonics less than 1% of the nominal value:Error is less than 0.05% rdg the nominal voltage current harmonics greater than 3% of the nominal value: the error is less than 1% edg current harmonics is less than 3% of the nominal value:Error is less than 0.05% of the nominal voltage interharmonic voltage interharmonic current Measurement method According to IEC61000-4-7, the magnitude of the analysis window 10 cycles Window points Every 10 cycles of 5120 points Display Form Sampling Frequency 200KHz Number of measurements 1~16 Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01 Measurement accuracy voltage harmonics greater than 1% of the nominal value: Error is less than 1% rdg voltage harmonics less than 1% of the nominal value:Error is less than 0.05% rdg the nominal voltage current harmonics greater than 3% of the nominal value: the error is less than 1% edg current harmonics is less than 3% of the nominal value:Error is less than 0.05% of the nominal voltage High harmonic voltage, high harmonic currents Measurement method Every 10 cycles of 5120 points Window points Every 10 cycles of 5120 points Display Form Sampling Frequency 200KHz Number of measurements 1 to 35 group Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01 Measurement accuracy voltage harmonics greater than 1% of the nominal value: Error is less than 1% rdg voltage harmonics less than 1% of the nominal value:Error is less than 0.05% rdg the nominal voltage current harmonics greater than 3% of the nominal value: the error is less than 1% edg current harmonics is less than 3% of the nominal value:Error is less than 0.05% of the nominal voltage Active power, reactive power, apparent power Measurement method Active power: 10 cycles computing Apparent power: Valid values of voltage and current operations Reactive Power: apparent power, active power is calculated Display Real-time data display Sampling Frequency 200KHz Measuring range / resolution Determined based on the voltage and current range Measurement accuracy ±0.5%rdg Power Factor Measurement method Rms, current rms voltage, active power is calculated Display Real-time data display Sampling Frequency 200KHz Measuring range / resolution -1.0000~1.0000 Measurement accuracy ±1%rdg Voltage unbalance, current unbalance (negative and zero sequence) Measurement method when 3-phase 3-wire or 3-phase 4-wire, calculate by three-phase fundamental ingredients Display Voltage unbalance current imbalance Sampling Frequency 200KHz Measuring range 0.00%~100% Measurement accuracy Voltage unbalance: ± 0.5% Current imbalance: ± 0.5% Voltage fluctuations Measurement method Half-wave to calculate the mean square Display The fluctuation trends, real-time values of voltage fluctuation Sampling Frequency 200KHz Measuring range 0.00%~100% Measurement accuracy ±1% IEC Flicker Measurement Item The short flicker (PST), long flicker (Plt) Measurement method According to IEC61000-4-15 10 minutes PST continuous measurement, continuous measurement and calculation 2 hours Plt Display The flicker trends, Pst value, Plt Measuring range 0~20 Measurement accuracy ±5% The impact of current Measurement method Half-wave rms current exceeds the set value of the positive impact of current Display The impact of current waveform, the impact of the current maximum Measurement accuracy 0.10% Measurement method Temporary swell: half-wave rms voltage positive direction exceeds a set value, it is determine as Temporary swell temporary sag: Valid values are negative direction exceeds a set value, determine as temporary sag Short interruptions: half-wave RMS voltage exceeds the set value in the negative direction, the decision for an instant interrupt Display Temporary swell, sag, short interruptions waveform duration, amplitude etc. Measurement accuracy 0.10% Temporary swell, sag, short interruptions waveform duration, amplitude etc
Product description Electrical equipments in modern industrial, commercial and residential users are more sensitive to power quality, and have a higher requirement of quality of power supply. Currently, harmonics,electromagnetic interference, power factor reduction have been tied to the three hazard of the power system. When it is interfered or contaminated, grid power quality canâ??t reach the national standards, so it has to be targeted on the grid power quality improvement. To understand the actual situation of power quality, you must have the appropriate equipment to test and analysis the actual situation. Counter the domestic condition, our company developed the professional power quality analysis instrument, which is suitable for the country. 3 phase handheld power quality analyzer Technical index 1. Input characteristics Voltage measuring range: 0 200V 800V, automatic cutting gear. Current measurement range Clamp transformers (three types): 5A / 25A (standard) 100A / 500A (optional) 400A / 2000A (optional) Phase angle measuring range: 0 ~ 359.99 . Frequency measurement range: 45 ~ 55Hz. Voltage channels: three-channel (UAã??UBã??UC). Current channels: three-channel (IAã??IBã??IC). Maximum harmonic analysis times: 63 times. Maximum continuous storage period in 1 minute interval: 18 months. 2. Accuracy
FUJI developed the first infrared gas analyzer in Japan to use mass-flow sensors. Since then, we have supplied customers with various types of gas analyzers to support environmental preservation and control efforts. These efforts include measurements of atmospheric pollution and detection of low density of SOx and NOx, generated by incinerating facilities and boilers. FUJI's gas analyzers are widely used to monitor the atmosphere to help maintain a cleaner natural environment.
Detailed product description 1. Power meter measures voltage, current, power, power factor, kwh, kvarh 2. Rs485/ modbus 3. Power quality analysis 4. Di/do PMAC735 power meter features: 1. Suit for lv/ hv voltage system 2. Compact design with all real-time measurement 3. Consist of basic unit and optional modules 4. 10 years back-up of integrated energy data 5. Large lcd, high brightness, auto-scrolling 6. High accuracy, v or i is 0.2%, kwh is class 1 7. Ct and pt programmable 8. Pluggable terminals, easy to install 9. Panel size: 96 x 96mm 10. Password protect PMAC735 power meter basic function: Provide one rs485 communication, measures and display real-time parameters: 1. Voltage¡ªua, ub, uc, uab, ubc, uca, 2. Current¡ªia, ib, ic, in 3. Active power ¨c pa, pb, pc, p 4. Reactive power ¨cqa, qb, qc, q 5. Apparent power¡ªsa, sb, sc, s 6. Power factor¡ªpfa, pfb, pfc, pf 7. Frequency 8. Active energy¡ªkwh (4 quadrant) 9. Reactive energy¨c kvarh (4 quadrant) 10. Demand and max. Record for i, p, q, s 11. Unbalance rate for u, i 12. Max./ min. Value Pmac735 power meter di/ do modules: 1. 4 status input + 4 relay output 2. 8 status input + 2 relay output 3. 8 status input + 2 pulse output 4. Profibus communication module Pmac735 power meter optional function: 1. Up to 31st harmonic analysis, k factor, thd 2. Soe (event log) 3. One 4~20ma analog output. Pilot's packing; neutral packing; customized packing.
Power meter, energy meter, power quality analyzer.
Our power cords are engineered for reliability and versatility available in both standard and customized configurations to meet your specific power needs Choose from 2pin and 3pin options to ensure compatibility with a wide range of devices and applications Key Features Versatile Pin Options Available in 2pin and 3pin configurations to accommodate various devices and power requirements Standard Options Premade power cords in commonly used lengths eg 1m 2m 3m for quick and easy deployment Customized Solutions Tailor your power cord to your exact specifications including length pin configuration and cable color HighQuality Materials Constructed from durable flameretardant materials to ensure safety and longevity Safety Certifications Compliant with international safety standards providing peace of mind for users Flexible Design The flexible cable design allows for easy routing in tight spaces while maintaining durability Wide Application Range Suitable for home appliances industrial equipment computers and more Key Advantages Enhanced Compatibility Ensures reliable connections for a variety of devices reducing the risk of power issues Customization Options Meet unique requirements by choosing the length pin type and other specifications tailored to your needs Durable and Safe Built to withstand everyday wear and tear with safety features that protect against overheating and electrical faults Convenient Lengths Options for different lengths help you manage space efficiently whether at home or in the workplace CostEffective Solution Highquality materials and customization options provide excellent value and longevity minimizing the need for replacements Whether you need a standard power cord for everyday use or a customized solution for a specific application weve got you covered Contact us today to find the perfect power cord for your needs
Marble, granite, stones, slates, tiles, power cord, wires, cables , cable assemblies, tyre scrap, used tyres, steel tire wire scrap, firewoods, pistachios, hazelnuts, textiles.
Air compressors, automation equipment, bearings, cables, diesel engines and generators & machinery spare parts, filters, electrical equipment's, electric motors and gear motors, panel boards and & much more..Logistics, customer clearance and much more.
.1 Description DEM8900-1/DEM8900-2/DEM8900-3 (short form for DEM8900) is designed by adopting the updated microprocessor and digital signal processing technology, which can be applied for monitoring the electrical system. DEM8900 can measure and analyze the real time electrical parameters, such as I,kWh,kvarh., Meanwhile, DEM8900 has functions of multi-tariff,RS485 communication ( MODBUS protocol),analog output, remote input and electrical pulse output. All our instruments fulfill all important requirements and regulations concerning electromagnetic compatibility and safety isolation (IEC61000, IEC1010 standard and EN61010 standard). The devices have been developed, manufactured, and tested in accordance with Quality Assurance System ISO 9001. 1.2 Measured parameters Note 1. DEM8900-1 measure current, active energy, active power (optional, with analog output) 2. DEM8900-2 measure current, reactive energy, reactive power (optional, with analog output) 3. DEM8900-3 measure Current, active energy, reactive energy, active/reactive power (optional, with analog output) 1.3 EMC and Safety standard IEC61000-4-2 (GB/T17626.2) IEC61000-4-8 (GB/T17626.8) IEC61000-4-4 (GB/T17626.4) IEC61010-1 (GB/T4793.1). Exterior Size:91*91*72mm 0.5KGS.
MPM8000 is a powerful multifunction power meter with modular design, which can be applied for monitoring and controlling of the electrical system. MPM8000 can measure and analyze real time data, such as U, I, P, Q, S, COS¦µ, F, kWh, kVAr, etc. MPM8000 has the following functions: RS-485 communication port, 2 energy pulse output (include active energy and reactive energy), Max/min data record, and SOE event record. MPM8000 can extend functions by choosing the external optional modules: harmonic analysis, 8 remote signals on/off mode, programmable 4 analog outputs (0~5V or 4~20mA optional), data storage, Profibus Com. protocol, Ethernet communication functions. The multi-tariff function allows the user to measure energy in any interval (the min. interval is 30min.), which can read the sum, sharp, peak, valley, flat energy data in 30 days, and measure 2nd to 63rd harmonics in statistics. All our instruments fulfill all important requirements and regulations concerning electromagnetic compatibility and safety isolation (IEC61000, IEC1010 standard and EN61010 standard). The devices have been developed, manufactured and tested in accordance with Quality Assurance System ISO 9001. EMC and safety standard IEC61000-4-2 (GB/T17626.2) IEC61000-4-8 (GB/T17626.8) IEC61000-4-4 (GB/T17626.4) IEC61010-1 (GB/T4793.1). Exterior Size:91*91*72mm. 0.5Kgs.