Product Parameters
Alternating current source
SMG7000 Handheld Power Quality Analyzer Accuracy
1. Electric parameter measurement part: Voltage: ± 0.2% Frequency: ± 0.01Hz
Current power: ± 0.5% Phase: ± 0.2
2. Power quality parts: Fundamental voltage permissible error 0.5%F.S.
Fundamental current allowable error:1%F.S.
3. Fundamental error of measurement of phase differencebetween voltage and current: 0.2
4. Harmonic voltage rate measurement error: 0.1%
5. Contain measurement error of harmonic current: 0.2%
6. Three-phase voltage unbalance error: 0.2%
7. Voltage deviation error: 0.2%
8. Voltage tolerance: 0.2%
working temperature:-10 ~ + 40 power supply: AC220V frequency 45Hz-55Hz
power consumption: 3VA battery operating time: less than 10 hours insulation:
1) input voltage and current on the chassis of theinsulation resistance: 100M Max.
2) power input terminals for shell under industrialfrequency 1.5KV (RMS) a 1-minute experiment.
9. Volume: 320mmx240mmx130mm
10. Weight: 2.0Kg
Monoblock pumps - Falcon centrifugal monoblock pumpsets are powered by a totally enclosed fan cooled AC induction two pole motor. Motor stator is made of low watt loss silicon steel laminations assembled under pressure and rigidly locked in the frame. The windings are of high-grade enameled copper wire offer excellent resistance and are varnish impregnated. Construction of motor frame and usage of quality materials result in high performance and low temperature rise thereby increasing the life cycle of the motor. salient features - High operating efficiency resulting in lower power consumption - Good suction lift characteristics - Inbuilt thermal overload protector in al single phase pumpsets upto 2.0 HP - Specially designed for wide voltage operation - Dynamically balanced rotating parts including rotor and impeller ensures minimum vibration and longer life - Back pull-out design for easy servicing and repair - Double shielded ball bearings, so no need of external lubrication - All Model fitted to Mechanical seal. specification - Power Range : 0.37Kw - 1.5 Kw (0.5 HP - 2.0 HP) - Version : Single Phase, 220-240V, 50Hz AC Supply Three Phase, 380-415V, 50Hz AC Supply - Speed : 2880 RPM - Maximum Total Head : 32 Mtr. - Maximum Flow Rate : 940 LPM - Maximum Suction Lift : 7 Mtr. - Degree of Protection : IP 44 - Class of Insulation : B0 - Maximum Ambient Tem. : 40 C - Sealing : Mechanical Seal - Type of Duty : S1 (Continuous) - Method of Starting : Permanent Split Capacitor (PSC) - Direction of Rotation : Three Phase, Electrically Reversible - Nominal Pumpset Size (Suction X Delivery in inch) : 25 X 25, 32 X 25, 40 X 32, 40 X 40, 50 X 40, 50 X 50, 65 X 50, 80 X 65, 80 X 80 (All size in mm) characteristics of clear cold water - Maximum liquid temperature : 33C max - Permissible amount of sand : 25 g/m - Allowable solids : 3000 ppm (max.) - Chloride ion density : 500 ppm (max.) - Turbidity : 50 ppm silica scale (max.) - Hardness (Drinking Water) : 300 ppm (max.) - Specific gravity : 1.004 (max.) 6 - Viscosity : 1.75 x 10 m/sec (max.) - Ph Value : 6.5 to 8.5 Part Name Material Mechanical Seal : Carbon & Ceramic Motor Shaft : EN-8 Motor Body : FG-250 Bearing : SKF End Cover : FG-250 Bracket : FG-250 Flange : FG-250 Casing : FG-250 Impeller : FG-250 Cooling Fan : Plastic
Monoblock Pumps Falcon centrifugal monoblock pumpsets are powered by a totally enclosed fan cooled AC induction two pole motor. Motor stator is made of low watt loss silicon steel laminations assembled under pressure and rigidly locked in the frame. The windings are of high-grade enameled copper wire offer excellent resistance and are varnish impregnated. Construction of motor frame and usage of quality materials result in high performance and low temperature rise thereby increasing the life cycle of the motor. salient features High operating efficiency resulting in lower power consumption - Good suction lift characteristics - Specially designed for wide voltage operation. - Dynamically balanced rotating parts including rotor and impeller ensures minimum vibration and longer life. - Back pull-out design for easy servicing and repair. - Double shielded ball bearings, so no need of external lubrication. - Mechanical seal is provided as per customers requirement Specification - Power Range : 2.2 Kw - 11.2 Kw (3.0 HP - 15.0 HP) - Version : Three Phase, 380-415V, 50Hz AC Supply - Speed : 2880 RPM - Maximum Total Head : 65 Mtr. - Maximum Flow Rate : 1450 LPM - Maximum Suction Lift : 7 Mtr. - Degree of Protection : IP 44 - Class of Insulation : B0 - Maximum Ambient Tem. : 40 C - Sealing : Stuffing Box - Type of Duty : S1 (Continuous) - Direction of Rotation : Three Phase, Electrically Reversible - Nominal Pumpset Size (Suction X Delivery in inch) : 50 X 40, 50 X 50, 65 X 50, 80 X 65, 80 X 80 100 X 80 and 100 X 100 (All size in mm) Characteristics Of Clear Cold Water - Maximum liquid temperature : 33C max - Permissible amount of sand : 25 g/m - Allowable solids : 3000 ppm (max.) - Chloride ion density : 500 ppm (max.) - Turbidity : 50 ppm silica scale (max.) - Hardness (Drinking Water) : 300 ppm (max.) - Specific gravity : 1.004 (max.) 6 - Viscosity : 1.75 x 10 mÃ?/sec (max.) - Ph Value : 6.5 to 8.5 Material of construction - motor Part Name Material Gland Dori : Graphite String Motor Shaft : EN-19 with SS SLEEVE Motor Body : FG-250 Bearing : SKF End Cover : FG-250 Bracket : FG-250 Flange : FG-250 Casing : FG-250 Impeller : FG-250 Cooling Fan : Aluminium
Falcon regenerative monoset pumpsets are powered by a totally enclosed fan cooled AC induction two pole motor. Motor stator is made of low watt loss silicon steel laminations assembled under pressure and rigidly locked in the frame. The windings are of high-grade enameled copper wire offer excellent resistance and are varnish impregnated. Construction of motor frame and usage of quality materials result in high performance and low temperature rise thereby increasing the life cycle of the motor. Salient Features High operating efficiency resulting in lower power consumption. - Good suction lift characteristics. - Specially designed for wide voltage operation. - Dynamically balanced rotating parts including rotor and impeller ensures minimum vibration and longer life. - Back pull-out design for easy servicing and repair. - Double shielded ball bearings, so no need of external lubrication. - All Model fitted to Mechanical seal. specification Power Range : 0.37 Kw - 0.75 Kw (0.5 HP - 1.0 HP) - Version : Single Phase, 220-240V, 50Hz AC Supply - Speed : 1440 RPM - Maximum Total Head : 18 Mtr. - Maximum Flow Rate : 4200 LPH - Maximum Suction Lift : 8 Mtr. - Degree of Protection : IP 44 - Class of Insulation : B0 - Maximum Ambient Tem. : 40 C - Sealing : Mechanical Seal - Type of Duty : S1 (Continuous) - Direction of Rotation : Single Phase, Clockwise from driving end - Nominal Pumpset Size (Suction X Delivery) : 25mm X 25mm Characteristics Of Clear Cold Water - Maximum liquid temperature : 33C max - Permissible amount of sand : 25 g/m - Allowable solids : 3000 ppm (max.) - Chloride ion density : 500 ppm (max.) - Turbidity : 50 ppm silica scale (max.) - Hardness (Drinking Water) : 300 ppm (max.) - Specific gravity : 1.004 (max.) 6 - Viscosity : 1.75 x 10 m/sec (max.) - Ph Value : 6.5 to 8.5 material Of construction - Motor Part Name Material Mechanical Seal : Carbon & Ceramic Motor Shaft : SS-410 Motor Body : FG-250 Bearing : SKF End Cover : FG-250 Bracket : FG-250 Flange : FG-250 Casing : FG-250 Impeller : Brass Cooling Fan : Plastic
Monoblock pumps Falcon centrifugal monoblock pumpsets are powered by a totally enclosed fan cooled AC induction two pole motor. Motor stator is made of low watt loss silicon steel laminations assembled under pressure and rigidly locked in the frame. The windings are of high-grade enameled copper wire offer excellent resistance and are varnish impregnated. Construction of motor frame and usage of quality materials result in high performance and low temperature rise thereby increasing the life cycle of the motor. Salient Features High operating efficiency resulting in lower power consumption. - Good suction lift characteristics. - Specially designed for wide voltage operation. - Dynamically balanced rotating parts including rotor and impeller ensures minimum vibration and longer life. - Back pull-out design for easy servicing and repair. - Double shielded ball bearings, so no need of external lubrication. specification - Power Range : 1.5 Kw - 5.5 Kw (2.0 HP - 7.5 HP) - Version : Three Phase, 380-415V, 50Hz AC Supply - Speed : 1440 RPM - Maximum Total Head : 12 Mtr. - Maximum Flow Rate : 3160 LPM - Maximum Suction Lift : 7 Mtr. - Degree of Protection : IP 44 - Class of Insulation : B0 - Maximum Ambient Tem. : 40 C - Sealing : Stuffing Box - Type of Duty : S1 (Continuous) - Direction of Rotation : Three Phase - Electrically Reversible - Nominal Pumpset Size (Suction X Delivery in inch) : 80 X 80, 100 X 100, 125 X 125, 150 X 150 (All size in mm) Characteristics Of Clear Cold Water - Maximum liquid temperature : 33C max - Permissible amount of sand : 25 g/m - Allowable solids : 3000 ppm (max.) - Chloride ion density : 500 ppm (max.) - Turbidity : 50 ppm silica scale (max.) - Hardness (Drinking Water) : 300 ppm (max.) - Specific gravity : 1.004 (max.) 6 - Viscosity : 1.75 x 10 m/sec (max.) - Ph Value : 6.5 to 8.5 Part Name Material Gland Dori : Graphite String Motor Shaft : EN-19 with SS SLEEVE Motor Body : FG-250 Bearing : SKF End Cover : FG-250 Bracket : FG-250 Flange : FG-250 Casing : FG-250 Impeller : FG-250 Cooling Fan : Aluminum
Supplier: Hydrogen oxygen gas generator, oxyhydrogen gas generator, hydrogen flame generator, micro flame generator, brown gas generator, micro flame welder, water welding machine, water welder, micro flame polisher, acrylic polishing machine, acrylic flame polisher
Usage The equipment is used to qualitatively or quantitatively measure the content of gasses (mainly hydrogen) in molten aluminum. It is an ideal practical method for evaluating the effect of degassing, the quality of molten aluminum and the performance of the melting technology.
Usage  The equipment is used to qualitatively or quantitatively measure the content of gasses (mainly hydrogen) in molten aluminum. It is an ideal practical method for evaluating the effect of degassing, the quality of molten aluminum and the performance of the melting technology.
Supplier: Generators set exhaust gas boilers, submerged arc furnace exhaust gas boilers, exhaust gas waste heat utilization and SCR denitrification integrated equipment, industrial kiln exhaust gas boiler, power plant low temperature economizers, oil & gas fired boilers, marine boilers, pressure vessels boiler tube
Services: Clearing Agent, Transportation , Shipping
Buyer: Pressure Flange, Valve
Supplier: Machines, machines' parts and related products for defense, oil & gas, power generation and aviation sectors.
Buyer: Machines, machines' parts and related products for defense, oil & gas, power generation and aviation sectors.