Features
Troubleshoot real-time: Analyze the trends using the cursors and zoom tools-even while background recording continues.
Automatic Transient Mode: Capture 200 kHz waveform data on all phases simultaneously up to 6 kV
Measure all three phases and neutral: With included four current probes
System-Monitor: Up to ten power quality parameters on one screen according to EN50160 power quality standard
View graphs and generate reports: With included analysis software
Logger function: Configure for any test condition with memory for over 400 parameters at user defined intervals.
Mains signaling: Measure interference from ripple control signals at specific frequencies
Inrush mode: For troubleshooting nuisance circuit breaker tripping.
AutoTrend: Every measurement you see is always automatically recorded, without any setup.
Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard.
Battery Life: Seven hours operating time per charge on NiMH battery pack
High safety rating: 600 V CAT IV/1000 V CAT III rated for use at the service entrance
• Comparing to online power quality analyzer, E6000 handheld type with small size, light weight, easy for the engineer to carry and carry out to survey work whenever and wherever.
• Easy to wiring
• It can operate directly to the line under test under the circumstances that the Power Grid without interrupt.
• Multi-range current switching
• based on actual demand, the different range of current clamp can be replaced to improve measurement accuracy.
Applications
Frontline troubleshooting - quickly diagnose problems on-screen to get your operation back online
Predictive maintenance - detect and prevent power quality issues before they cause downtime
Quality of service compliance - validate incoming power quality at the service entrance
Long-term analysis - uncover hard-to-find or intermittent issues
Load studies - verify electrical system capacity before adding loads
Energy assessments - quantify energy consumption before and after improvements to justify energy saving devices.
Specifications
Measurement Items
Be measured Type of measurement
RMS Voltage Voltage
RMS Current Current
Frequency Deviation Frequency
Three-phase Unblanced Voltage, Current
Voltage fluctuations Voltage
Flicker Voltage
Harmonics and inter-harmonics, higher harmonic Voltage, current
Power Active, reactive, apparent power factor
Event log Transient pulse, the voltage rise, voltage sags, voltage interruption, the impact of current, frequency of abnormal
Input parameter
Measuring circuit 1P2W, 1P3W, 3P3W, 3P4W
The fundamental frequency of the measuring circuit 50Hz/60Hz
Number of input channels Voltage, current, 4
Measurement range Voltage Measurement Range: Nominal value: 100V, 230V, 400V, maximum 1000V
Current measurement range: Depending on the current clamp, current clamp the output voltage signal, the maximum voltage: 10V peak
Environmental security parameters
Use of the environment 0 ° C to +45 ° C, humidity 90rh%
Storage environment -20 ° C to +50 ° C, 95RH% humidity (non-condensing)
Power input voltage +100VAC ~ +240VAC
Electromagnetic Compatibility Level 3: GB / T 17626.2-2006 Electrostatic Discharge Immunity
Level 3: GB / T 17626.3-2006 RF electromagnetic radiation the Immunity
Level 3: GB / T 17626.4-2008 electrical fast transient burst immunity
Level3: GB / T 17626.5-2008 surge (impact) Immunity
Level 3: GB / T 17626.8-2006 frequency magnetic field immunity
Level 3: GB / T 17626.9-1998 Pulse magnetic field immunity
Level 3: GB / T 17626.12 -1998 Oscillatory waves immunity
Environmental reliability GB/T 2423.1-2008 low temperature
GB/T 2423.2-2008 high temperature
GB/T 2423.4-2008 alternating hot and humid
GB/T 2423.5-1995 impact
GB/T 2423.10-2008 vibration
GB/T 2423.22-2002 temperature changes
Dustproof, waterproof IP20(GB 4208-93/IEC 529:1989)
Security 500V/10M,2KV:GB/T 15479-1995
External interface parameters
USB Device 1 The upload power quality data
TF card to expand storage 1 Built-in capacity Optional, up to 8G
Battery 1 4500mAh Ni-MH battery
LCD 1 26 million color 5.6-inch LCD screen with a resolution of 640 * 480
Voltage and current measurement interface 8 Test voltage and current input port
Frequency
Measurement method 10 waveform (50Hz) the calculated frequency
Display Display of a channel frequency value
Measuring range / resolution 50.0000Hz/0.0001Hz
Measurement bandwidth 42.5000~57.5000Hz
Measurement accuracy ±0.001Hz
1/2 rms voltage 1/2 rms, current
Measurement method Once every two cycle operations, a waveform operations per cycle to take 1/2 cycle
Sampling Frequency 200K
Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01,Based on the use of current clamp
Measurement accuracy 0.1% of the nominal voltage
RMS voltage
Measurement method 10 waveforms (50Hz) the operator
Display Per channel RMS voltage
Sampling Frequency 200K
Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01
Measurement accuracy 0.1% of the nominal voltage
RMS voltage
Measurement method 10 waveforms (50Hz) the operator
Display Current per channel RMS
Sampling Frequency 200K
Measuring range / resolution Based on the use of current clamp
Measurement accuracy 0.1% of the nominal voltage
Harmonic voltage, harmonic current
Measurement method According to IEC61000-4-7, the magnitude of the analysis window 10 cycles
Window points Every 10 cycles of 5120 points
Display Histograms, tables
Sampling Frequency 200KHz
Number of measurements 0~50
Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01
Measurement accuracy voltage harmonics greater than 1% of the nominal value: Error is less than 1% rdg
voltage harmonics less than 1% of the nominal value:Error is less than 0.05% rdg
the nominal voltage current harmonics greater than 3% of the nominal value: the error is less than 1% edg
current harmonics is less than 3% of the nominal value:Error is less than 0.05% of the nominal voltage
interharmonic voltage interharmonic current
Measurement method According to IEC61000-4-7, the magnitude of the analysis window 10 cycles
Window points Every 10 cycles of 5120 points
Display Form
Sampling Frequency 200KHz
Number of measurements 1~16
Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01
Measurement accuracy voltage harmonics greater than 1% of the nominal value: Error is less than 1% rdg
voltage harmonics less than 1% of the nominal value:Error is less than 0.05% rdg
the nominal voltage current harmonics greater than 3% of the nominal value: the error is less than 1% edg
current harmonics is less than 3% of the nominal value:Error is less than 0.05% of the nominal voltage
High harmonic voltage, high harmonic currents
Measurement method Every 10 cycles of 5120 points
Window points Every 10 cycles of 5120 points
Display Form
Sampling Frequency 200KHz
Number of measurements 1 to 35 group
Measuring range / resolution 120V/0.01,230V/0.01,400V/0.01
Measurement accuracy voltage harmonics greater than 1% of the nominal value: Error is less than 1% rdg
voltage harmonics less than 1% of the nominal value:Error is less than 0.05% rdg
the nominal voltage current harmonics greater than 3% of the nominal value: the error is less than 1% edg
current harmonics is less than 3% of the nominal value:Error is less than 0.05% of the nominal voltage
Active power, reactive power, apparent power
Measurement method Active power: 10 cycles computing
Apparent power: Valid values of voltage and current operations
Reactive Power: apparent power, active power is calculated
Display Real-time data display
Sampling Frequency 200KHz
Measuring range / resolution Determined based on the voltage and current range
Measurement accuracy ±0.5%rdg
Power Factor
Measurement method Rms, current rms voltage, active power is calculated
Display Real-time data display
Sampling Frequency 200KHz
Measuring range / resolution -1.0000~1.0000
Measurement accuracy ±1%rdg
Voltage unbalance, current unbalance (negative and zero sequence)
Measurement method when 3-phase 3-wire or 3-phase 4-wire, calculate by three-phase fundamental ingredients
Display Voltage unbalance
current imbalance
Sampling Frequency 200KHz
Measuring range 0.00%~100%
Measurement accuracy Voltage unbalance: ± 0.5%
Current imbalance: ± 0.5%
Voltage fluctuations
Measurement method Half-wave to calculate the mean square
Display The fluctuation trends, real-time values of voltage fluctuation
Sampling Frequency 200KHz
Measuring range 0.00%~100%
Measurement accuracy ±1%
IEC Flicker
Measurement Item The short flicker (PST), long flicker (Plt)
Measurement method According to IEC61000-4-15 10 minutes PST continuous measurement, continuous measurement and calculation 2 hours Plt
Display The flicker trends, Pst value, Plt
Measuring range 0~20
Measurement accuracy ±5%
The impact of current
Measurement method Half-wave rms current exceeds the set value of the positive impact of current
Display The impact of current waveform, the impact of the current maximum
Measurement accuracy 0.10%
Measurement method Temporary swell: half-wave rms voltage positive direction exceeds a set value, it is determine as Temporary swell
temporary sag: Valid values are negative direction exceeds a set value, determine as temporary sag
Short interruptions: half-wave RMS voltage exceeds the set value in the negative direction, the decision for an instant interrupt
Display Temporary swell, sag, short interruptions waveform duration, amplitude etc.
Measurement accuracy 0.10%
Temporary swell, sag, short interruptions waveform duration, amplitude etc
Power 900W LED Qty 72pcs 5W LED & 6pcs 90W COB Voltage AC85-265V Work frequency 50/60Hz Lumen >15400Lm Dimmension 660X385X118mm N.W 11.4kg Coverage 1.0 1.2 m Warranty 50000 hours
Power 1200W LED Qty 96pcs 5W LED & 8pcs 90W COB Voltage AC85-265V Work frequency 50/60Hz Lumen 21050Lm Dimmension 848X385 X118mm N.W 14.8kg Coverage 1.5 X1.0 m Warranty 50000 hours
LED light.
For the Mosquito killer Led Bulb Light, is a 900 lumen bulb that doubles as an insect killer. The light features a blue UV LED which attracts insects into a Mosquito Killer grid.And the Mosquito Killer grid uses only 1W of electricity, while the light itself uses a meager 9W – and both can be used independently.They are used at home and outdoor. A brush is provided to clean off insects once the bulb switched-off.Compare to other traditional mosquito killer, this bulb has no chemicals, no sprays and hence no fumes to our life. • 2nd generation 2-in-1 LED LIGHT Bulb Plus LED Mosquito Killer Bulb • Wattage: 10W • Blue UV light • Lumen: 900-1000lm • Color Temperature (CCT): 6500K • Input Voltage: AC 90-130V & 220v-240V • With CE and ROHS Operation: Step1: Switch it on,both lighting +killing are on. Step2: Switch on again,light off,only killing on. Step3: Switch on again,killing off,only light on. Step4: Switch off, both off.
Powerï¼? 900W LED Qtyï¼? 72pcs 5W LED & 6pcs 90W COB Voltage ï¼? AC85-265V Work frequencyï¼? 50/60Hz Lumen ï¼? >15400Lm Dimmensionï¼? 660X385X118mm N.W ï¼? 11.4kg Coverage ï¼? 1.0Ã?1.2 m Warranty ï¼? 50000 hours
Supplier: 1. korea cosmetic
2. korea cosmetic raw material
3. consumer goods
4. korea materials, parts, eqipments
Services: We offer all cosmetics from korea.
we are connected to various partners, so we can supply a wide range of products at the lowest prices.
we also offer beauty and plastic surgery products.
in addition, we supply various korean materials, parts, and equipment.
Buyer: Material, parts and equipment
Supplier: Wireless charger, batteries power bank, dust sensor, optical disc drive, tof, lidar, ar glass
Supplier: Rice, cotton yarn, fresh fruits, dry fruits & nuts, fresh vegetables, honey, leather products, leather shoes, leather belts, leather gloves, surgical gloves, solar led street lights, petroleum by products, herbs, solar lights, light emitting diode, knitted & woven garments, street lights & lamps, made ups, energy saving lights & lamps, pink salt, himalayan salt, rock salt, salt, leather bags
Services: Trading services.
Supplier: 1. lighting products:
* indoor luminaires (including led bulb, led tube, led panel, led slim panel, led batten, led ceiling, led cross and linear light, led high bay, led parking, led downlight, led track light);
* outdoor luminaires (including led flood light, led solar flood light, led street light, led solar street light.)
* led grow lights (a variety of professional grow lights for dragon fruit, chrysanthemum, medicinal plants, ginseng, tomatoes, strawberries, grapes, watermelons, cantaloupe, bell peppers, orchids, vegetables, algae, etc.);
* fishing lights (including on boat lights and underwater lights);
2. kitchenware products: vacuum flask, water bottle, electric kettle; electric blender, rice cooker, glass liner and accessories.
Services: Manufacturing, export and import, transport, and odm/oem services for all of the products.