Detailed product description 1. Power meter measures voltage, current, power, power factor, kwh, kvarh 2. Rs485/ modbus 3. Power quality analysis 4. Di/do PMAC735 power meter features: 1. Suit for lv/ hv voltage system 2. Compact design with all real-time measurement 3. Consist of basic unit and optional modules 4. 10 years back-up of integrated energy data 5. Large lcd, high brightness, auto-scrolling 6. High accuracy, v or i is 0.2%, kwh is class 1 7. Ct and pt programmable 8. Pluggable terminals, easy to install 9. Panel size: 96 x 96mm 10. Password protect PMAC735 power meter basic function: Provide one rs485 communication, measures and display real-time parameters: 1. Voltage¡ªua, ub, uc, uab, ubc, uca, 2. Current¡ªia, ib, ic, in 3. Active power ¨c pa, pb, pc, p 4. Reactive power ¨cqa, qb, qc, q 5. Apparent power¡ªsa, sb, sc, s 6. Power factor¡ªpfa, pfb, pfc, pf 7. Frequency 8. Active energy¡ªkwh (4 quadrant) 9. Reactive energy¨c kvarh (4 quadrant) 10. Demand and max. Record for i, p, q, s 11. Unbalance rate for u, i 12. Max./ min. Value Pmac735 power meter di/ do modules: 1. 4 status input + 4 relay output 2. 8 status input + 2 relay output 3. 8 status input + 2 pulse output 4. Profibus communication module Pmac735 power meter optional function: 1. Up to 31st harmonic analysis, k factor, thd 2. Soe (event log) 3. One 4~20ma analog output. Pilot's packing; neutral packing; customized packing.
MPM8000 is a powerful multifunction power meter with modular design, which can be applied for monitoring and controlling of the electrical system. MPM8000 can measure and analyze real time data, such as U, I, P, Q, S, COS¦µ, F, kWh, kVAr, etc. MPM8000 has the following functions: RS-485 communication port, 2 energy pulse output (include active energy and reactive energy), Max/min data record, and SOE event record. MPM8000 can extend functions by choosing the external optional modules: harmonic analysis, 8 remote signals on/off mode, programmable 4 analog outputs (0~5V or 4~20mA optional), data storage, Profibus Com. protocol, Ethernet communication functions. The multi-tariff function allows the user to measure energy in any interval (the min. interval is 30min.), which can read the sum, sharp, peak, valley, flat energy data in 30 days, and measure 2nd to 63rd harmonics in statistics. All our instruments fulfill all important requirements and regulations concerning electromagnetic compatibility and safety isolation (IEC61000, IEC1010 standard and EN61010 standard). The devices have been developed, manufactured and tested in accordance with Quality Assurance System ISO 9001. EMC and safety standard IEC61000-4-2 (GB/T17626.2) IEC61000-4-8 (GB/T17626.8) IEC61000-4-4 (GB/T17626.4) IEC61010-1 (GB/T4793.1). Exterior Size:91*91*72mm. 0.5Kgs.
1.Product Profile QAM8300-1M power quality analyzer is an integrated monitoring, analyzing and controlling device that offers electrical parameter metering, harmonics metering and analysis, waveform sampling, measurement of Voltage swell, dip, interrupt, Voltage unbalanced ratio, fault record, event record, data record. QAM8300-1M can monitor and detect if the power quality fulfills IEC and EN standard. With its powerful I/O functions with exterior device, QAM8300-1M can perform harmonic control, PF adjustment, and demand monitoring functions. QAM8300-1M fulfils all the important requirements of IEC 61000-4-30 Class A standard. QAM8300-1M can work with our power quality monitoring and management software to provide energy management solutions for enterprises. With its strong networking capability, QAM8300-1M can display and record all the data records on the interactive trend chart. A data report can be formed periodically. The report can be used for fault analysis, statistics, real time monitoring purpose. QAM8300-1M fulfills IEC61000-4-30 A: 2003,IEC61000-4-15:2003,IEC61000-4-7:2002,EN50160,2004 etc standards. 2.Measurement Accuracy U, I: 0.1% U, I peak value, peak factor, flicker: 0.5% 3 phase Voltage unbalanced ratio: 0.2% 3 phase Current unbalanced ratio: 0.5% Frequency: 0 .002Hz Power factor: 0 .002 Power: 0.2% Energy: Active energy 0.2% IEC60687:1992(GB/T17883-1999) Reactive energy 0.2% IEC61268(1995) (GB/T17882-1999) Harmonics: IEC61000-4-30 class A Interharmonics: IEC 61000-4-30 class A Harmonic distortion rate: 2.5% 3.EMC and safety test EN61326-1 EN61000-4-2/3/4/5/12 IEC/EN61010-2001.
.1 Description DEM8900-1/DEM8900-2/DEM8900-3 (short form for DEM8900) is designed by adopting the updated microprocessor and digital signal processing technology, which can be applied for monitoring the electrical system. DEM8900 can measure and analyze the real time electrical parameters, such as I,kWh,kvarh., Meanwhile, DEM8900 has functions of multi-tariff,RS485 communication ( MODBUS protocol),analog output, remote input and electrical pulse output. All our instruments fulfill all important requirements and regulations concerning electromagnetic compatibility and safety isolation (IEC61000, IEC1010 standard and EN61010 standard). The devices have been developed, manufactured, and tested in accordance with Quality Assurance System ISO 9001. 1.2 Measured parameters Note 1. DEM8900-1 measure current, active energy, active power (optional, with analog output) 2. DEM8900-2 measure current, reactive energy, reactive power (optional, with analog output) 3. DEM8900-3 measure Current, active energy, reactive energy, active/reactive power (optional, with analog output) 1.3 EMC and Safety standard IEC61000-4-2 (GB/T17626.2) IEC61000-4-8 (GB/T17626.8) IEC61000-4-4 (GB/T17626.4) IEC61010-1 (GB/T4793.1). Exterior Size:91*91*72mm 0.5KGS.
Supplier: Power meter, multifunction power meter, energy meter, power quality analyzer, wireless temperature and humidity measurement system
SA2100 Class S Power Quality Analyzer Overview SA2100 is a handheld multi-functional device which is designed to measure and analyze single or three-phase power system. This portable class S device can provide safe, convenient and accurate measurements for troubleshooting power networks. SA2100 Portable Power Quality Meters Portable Power Quality Meters enable electricians and facility maintenance professionals to troubleshoot and benchmark power quality problems over time. They help you identify energy waste in your facility and detect and prevent power problems before they occur. Why do you need Power quality meter analyzer? Portable Power Quality Meter identifies power quality problems that often manifest themselves as dips, spikes, harmonic distortion, imbalances, flicker and transients. Power quality determines the suitability of electrical energy to drive motors, machines and other end-user equipment. Poor power quality can affect the ability of these devices to operate properly, which can lead to malfunctions, premature failures or possibly cause them to not work at all. Most power quality analyzers monitor total harmonic distortion, phase angle, power factor, balance, etc. to get a complete picture of the system.
Multifunction Power Meter: CPM-12D is a din rail mounting multifunction power meter with high accuracy measurement for single phase and three-phase system. Measuring all basic parameters ; V, I, P, Q, kWh, kVarh etc.. 1 RS485 Modbus RTU communication port as default, LCD display in front panel with buttons for programming. Auto wiring change (see remark as below) via software CE and FCC approved Remark: Auto wiring change have certain condition limit, please refer to operation manual for further details. Â Applications Energy management system Factory automation Intelligent power panel Industrial automation Power Grid automation Community power monitoring Intelligent green building
BJ194E-9S4, with its four direct access keys and LED displays, helps you use all the parameters in 3P3W or 3P4W LV installation. These parameters can be centralized on a PC or PLC through an RS 235 link using MODBUS protocol. The casing is designed so that the installer can easily fit the meter to the door of a cabinet. Applications 1. Metering of distribution feeders, transformers, generators, capacitor banks and motors 2. Medium and low voltage systems 3. Commercial, industrial, utility Features 1.Class 0.2 or 0.5 power and energy 2.Current measuring .../5 or .../1 A 3.Option RS-232 Modbus/RTU Communications 4.Expandable input / output modules (up to 3 modules) 5.ITF Technology: galvanic insulation protection inputs outputs 6.Universal series power supply
An electric meter, or energy meter, is a device that measures the amount of electric energy consumed by a building, tenant space, or electrically powered equipment. Electric utilities use electric meters installed at customers' premises to measure electric energy delivered to their customers for billing purposes