Cast resin transformers Range:160 KVA 11KV up to 10,000 KVA, 33 KV Class In addition to the above, we are capable to supply cast resin dry type transformers for a client's special and stringent requirements to converter, rectifier, static excitation and other special applications as well Standards:
Cast resin transformers Range:160 KVA 11KV up to 10,000 KVA, 33 KV Class In addition to the above, we are capable to supply cast resin dry type transformers for a client's special and stringent requirements to converter, rectifier, static excitation and other special applications as well Standards:
Cast resin transformers Range:160 KVA 11KV up to 10,000 KVA, 33 KV Class In addition to the above, we are capable to supply cast resin dry type transformers for a client's special and stringent requirements to converter, rectifier, static excitation and other special applications as well Standards:
Cast resin transformer For the demand of safety for the power distribution equipment, dry type transformers with fire resistant, non-polluting and humidity resistant features are often the right choice. Hsl cast resin transformer will provide the best and safest solution to all kinds of power distribution system application. Features: Hazard-free to the environment Designed for reliability, safety and flexibility, hslí»s medium voltage cast resin transformers are tropicalized, maintenance-free, environmental-friendly, flame-resistant, self-extinguishing, moisture-proof and space optimization and suitable for application to a wide range of industries such as high rise buildings, power plant, airport, hospitals, museum, hotels, all sectors of industry, surface, underground and tunnel railway systems, oilfield, electric grid, mining, etc. Our standard range of cast resin transformers is 30kva up to 2500 kva, however, we are able to design and manufacture special units to suit most applications. The magnetic cores are made of low specific loss high magnetic silicon steel isolated on both sides by a thin inorganic coating (carlyte). The cores are cut at 45 degrees while uniform pressing, stiffness and solidity of the columns assure a low noise emission. The hv windings, coaxial to the column of the core, are obtained using electrolytic aluminum or copper strips insulated in f class, impregnated to a vacuum system with oven-dried in class f, a high level of cementation which provides the coils a very good isolation and mechanical seal. The lv windings are generally made from electrolytic aluminum or copper foils having class f inter-turn pre-impregnated film insulated and then oven dried. Hsl is an iso9001:2000 compliance manufacturer. Our transformers will be 3-phase, 50hz in frequency, naturally cooled and are manufactured equivalent of iec726 standards. Subject to capacity Packed in wooden crates
Resin cast current transformers are available for metering and protection application. These current transformers are mainly fabricated according to client’s specification. Ct coils are encapsulated in cast resin (polyester / epoxy). Secondary terminals are provided with either screws or studs. The main insulation between primary and secondary and earth is obtained by this epoxy resin. These transformers are of compact design with high mechanical and electrical properties. These are non-hygroscopic and hence give very good insulation properties even in given humid conditions. General particulars Rated voltage: 11 kv Rated primary current: 100 a Rated secondary current: 1a or 5a Rate burden: 5va Rated frequency: 50hz Accuracy class: 0.5 or 0.5s Temperature: as per is-2705/1992 Highest system voltage: 12kv Insulation level: 28kvrms/75kv(p) Stc: 13.1ka for 1 sec Continues thermal current: 1.2 times of rated current Core material: crgo Copper wire material: enameled wire as per is-4800 part-4 or iec-317 Insulation class/material: epoxy resin Secondary terminal: m5 brass bolt with nut &washer or m5 threaded bush with screw &washer Primary terminal p1 & p2 size and material Mounting base: ms 5mm thick zinc plated Rountine test :as per is-2705/1992
We manufacture highly efficient and accurate resin cast potential transformers. These resin cast potential transformers are used in ac circuits, for the purpose of measuring large voltages. Their main function is to reduce the supply voltage to a small value so that it can be easily measured with standard low range ac instruments of moderate size and capacity. There are many advantages of using resin cast potential transformers for range extension of ac meters. We also offer resin cast potential transformers of dual purpose metering & protection that are also commonly used.
Standards IEC60044-1; IEC 61869-2; ANSI C57.13; NTC 2205; GB1208-2006 Rated primary current 30-1000A Rated load 20VA Rated frequency 50Hz or 60Hz Rated secondary current 5A or 1A Rated short-time thermal current 40kA, 1S Rated continuous thermal current 120%I1n Secondary winding power-frequency voltage 3kV, 1min Instrument security factor FS 10 Mechanical parameters Dimensions (WDH) (mm) 45x120x65 Weight (kg) 2.1 Operating conditions Operating temperature -35C to +55C Daily average temp
Product Description Type: Dry Type Transformer Model Number: SC(B)10-30~2500/35 Phase: Three Rated High Voltage: 10(11, 10.5, 6.6, 6.3, 6 )KV Rated Low Voltage: 10KV, 0.4KV or as required Rated Capacity: 30~2500KVA Our dry type transformers are in conformity with the following standards: 1. National Standard of China GB1904.11-2007Power Transformers 2. International Electro Technical Commission Standards IEC 60076-112004 Dry Type Transformers 3. German Industry Standard DIN EN 60076-11:2005 Dry Type Transformers
33KV epoxy resin cast transformer used in buildings power distribution Specification Mainly Products: No. Type Model 1 Dry Type Transformer SCB10-30~3150/10 2 Amorphous Core Transformer SH15-30~2500/10 3 Power Transformer SZ11-630~31500/35 4 Three Phase Oil Immersed Transformer S11(13)-M-30~1600 dry type transformer dry transformer epoxy resin cast transformer cast resin dry type transformer Product description Product discription: Feature: 1) Epoxy resin casting dry-type transformer 2) Rated capacity is 30-3105KVA, larger transformer capacity customized 3) Cold rolled orientation silicon steel core 4) All inclined seam segmented type structure. 5) Low voltage winding with Foil type winding structure 6) High voltage winding with layers structure 7) Small volume and light weight dry type transformer dry transformer epoxy resin cast transformer cast resin dry type transformer Advantage: 1) High reliability and long service life. 2) Different operating environment, different protection level or not. 3) Safe, fire resistant, no pollution 4) High strength and anti-short circuit ability 5) Super heat dispersion and moisture resistance 6) low cost of installation 33KV 2500kva vacuum dry type transformer used in buildings Application: Widely used in high rise building, business center, airport, tunnel, nuclear power plant, chemical plant, shipbuilding, petrochemical and other special environment place instead of the oil immersed transformer. 33KV 2500kva vacuum dry type transformer used in buildings Packaging & Shipping Packing and shipping: 1) Port of loading: Qingdao, China. 2) Delivery period: 30 days after drawing confirmed by buyer. 3) Package: the accessories packed in plywood cases and the main body in nude. 4) Warranty period: 12 months 5) Valid time:60 days 33KV 2500kva vacuum dry type transformer used in buildings Our Services: 1) Excellent production team. 2) Best qulitity products. 3) Professional after-sales. 4) Prompt reply for your inquiry and feedback. 33KV 2500kva vacuum dry type transformer used in buildings Certifications power transformer, oil immersed transformer, dry type transformer, switchgear cubicle, switchgear, switch cabinet are all manufactured here. And followings are our main certification and cooperators.
SCB13 dry type power transformer product features. Low loss: the no-load loss of the product is 20% lower than that of the SCB11 product, and the energy saving effect is excellent, running economy and maintenance free. Low noise: product noise level is 10 to 15 decibels lower than the current professional standard JB/ t10088-1999 "6-220kv transformer sound level". Low set: resin mixed materials adopt the most advanced mixing method in foreign countries and vacuum film degassing technology, so that the mixture is evenly mixed and the bubbles in the mixture are excluded. The product only has extremely low local discharge, can be controlled under 5PC. The high and low pressure coils are poured under vacuum and pressure, so that the resin insulation can be both encapsulated and inter-turn. The casting body has a dense solidified structure, which is resistant, explosion-proof and pollution-free. The glass fiber and other insulating materials of winding coil have self-extinguishing characteristics, which will not cause the electric arc of short circuit, and the resin will not produce poisonous and harmful gas in high heat. High mechanical strength: packing resin to make casting body expansion coefficient difference is small, small curing shrinkage rate, small internal stress, curing of high hardness, the internal and external surfaces of the high and low voltage coil epoxy resin coating layer, placed with the strengthening of prefabricated molding material, especially as dense as the reinforced concrete structure, and mechanical strength is greater than the pure epoxy resin, can withstand the sudden and short-circuit force without damage.
Current transformer, potential transformer, epoxy resin, cast components.
Transformers,Distribution and Power Transformer,Varivolt Safety Transformers Diesel Generators Industrial Panels Stabilizers Energy Saver Industrial Panels
DATA SHEET FOR EPOXY EPOXY COATING :- INTRODUCTION - EPOXY COATING (HYB) is a two part high solids solvent free epoxy phenolic resin based coating system designed for hard wearing, smooth surface finish for floors, walls and on steel structures. Nonskid surface finish can be achieved on floor, if required. FEATURES: 1) Hard Wearing 2) Non Dusting 3) Excellent Surface Finish 4) Non Smelling 5) Good Aesthetics 6) Highly Chemical Resistant APPLICATION: 1.Stir well before mixing Part A and Part B and mix in the prescribed ratio. 2.Apply one coat of EPOXY primer on the clean and dry surface. 3.EPOXY COATING (HYB) should be applied on the surface by brush or roller within 24 hrs. After application of primer coat it should be allowed to air dry for min. 4 hrs. Preferable in a dust free atmosphere. 4.Apply min. 2 coats with the intercoat interval of 6-8 hrs. PRODUCT SPECIFICATIONS: Application - Brush, Roller Mixing Ratio - As Directed on Packing Port Life - 30 Mins. Drying Time - Touch Dry- 30 Min, Hard Dry 6 Hrs. - Intercoat Interval 6-8 Hrs. Min. - Dry Film Thickness 125-150 Microns/per coat - depending on porosity Covering Capacity - 6-8 sq.met/kg per coat depending on porosity, roughness & method of application. Color Shades - All Standard Shades RECOMMENDED USES: 1) Food & Pharmaceutical 2) Work Shop 3) Clean Room Application 4) Chemical Resistant Coating for Concrete& Steel 5) Petrochemical, Fertilizer plants METHOD OF APPLICATION: SURFACE PREPARATION The long-term durability of the applied Epoxy coating (HYB) epoxy coating is dependent on the adhesion between sub-base and coating material. It is most important therefore, that the substrate surfaces are correctly prepared prior to application. 1.Before application of the Epoxy coating (HYB) surface should be free from loose partials, rust, oils, grease or earlier coatings and should be totally dry. 2.New concrete or cementations surface should be placed at least 28 days and have a moisture content of less than 5% before application of Epoxy coating (HYB) 3.After surface is dry, all repair work like sealing of joints, cracks filling of cavities and crevices should be carried out. HEALTH & SAFETY - Keep the containers tightly closed when not in use. Avoid contact with skin & eyes. It comes in contact with the body, wash affected parts with plenty of water and contact a doctor. Other known sector for Epoxy floor lining, Epoxy garage floor lining, Concrete epoxy lining, Concrete floor epoxy lining, Epoxy pipe lining, Marine epoxy lining, Sub marine epoxy lining, Basement lining epoxy floor shield, Louisiana, Oregon, Chip lining color epoxy floor, Aviation lining epoxy interior.
Multi-layer winding coil Low-voltage coil adopted high quality foil and rolled with the automatic foil machine, argon arc welding with high-accuracy standard; presoak dmd in the interlamination as insulation material. Use presoak glass for insulation both outside and inside, sealed with epoxy resin, followed by solidify in the curing oven, in order to reached the target of high level of humidity resistance. About amorphous metal transformer Amorphous metal transformer introduction The development of the amorphous metal in 1970s, it has been widely used in 1990 for a high energy saving material for the transformer industry. Right now, over one million sets of amorphous metal type transformer had been connected to grid all over the world. The longest proven save and reliable transformer had been running for more than 30 years, and it still perform satisfactory in the power industry. The energy saving is huge and it shall be the new era products in the power industry