Same features as the UM-2, Plus Echo-Echo Mode (Thru Paint & Coatings) Measuring range: 0.03'' to 12'',with compensation line for 7 types of Probe/Transducer 128 x 64 pixel graphical LCD with EL backlight Stores 500 readings in 5 groups of 100, V- path correction, Alarm Mode and Minimum Capture Up to 200 hours with two 1.5V AA alkaline batteries (without backlight), AUTO-OFF after 5 minutes of inactivity
Same features as the UM-5, Plus Echo-Echo Mode (Thru Paint & Coatings) Utilizing color waveform A-scan and time based B-scan for absolute correctness Measuring range: 0.02'' to 20'' (depends on material, probe and surface condition) Dynamic Waveform and Thickness Color Change on Alarm Up to 40 hours operating time with two AA alkaline batteries, Alternative Auto-Off time
Compact and low-cost coating thickness gauge - for all coatings on steel e. g. paints, enamels, chrome, zinc - and for all insulating coatings on nonferrous metals e. g. anodising or paint on aluminium, zinc diecasting etc. Application This compact, practical hand-held gauge has been designed for nondestructive, fast and precise coating thickness measurement. Depending on gauge type, (see delivery schedule) measurements can be taken on - all non-magnetic coatings (e. G. Paints, enamels, chrome, zinc etc. ) on steel - all insulating coatings (anodising, paint coatings, ceramics) on all non-ferrous metals such as aluminium, copper, brass, ustenitic stainless steel. The gauge has especially been designed for use in the field of industrial corrosion prevention. Readings as well as statistical values can be documented with the portable miniprint data printer. For measurements in dark areas all models feature display backlight. Description The single pole probe is connected to the gauge by a 1 metre cable. The newly developed probe tip is made from very hard and wear resistant material which guarantees virtually unlimited life provided it is handled correctly. According to model, the gauge is supplied with: - a magnetic-induction probe for measurements on steel (f) or - an eddy current probe for measurements on nonferrous metals (n) or - a dual probe (fn) for measurements on steel and on nonferrous metal substrates (fn) New! The dual fn probe automatically adjusts to the correct substrate metal: Ferrous/non-ferrous. This feature is not available with the 500 model. The gauges conform to din, iso, bs, astm.
Product description Amittari standard type coating thickness gauge ac-110 series have 2 types: type a ( integral type ), type as ( separate Type). Integral type suitable for single-hand operation, large probe with large contact surface have better stability, users can get continuous, good repetitive and precise measurements. Separate type can provide several type probe, measure can bemore flexibility. Product parameters Measuring range0~1250 um 0~50mil (other range may be specified) Resolution0.1 um (0~99.9um)/1 um (over 100um) Accuracy:1~3%n or 2.5 um or 0.1mil (whichever is the greater) Humidity:
Product description The basic type coating thickness gauge ac-110 series have two types: type c ( integral type ), type cs ( separate type ); suitable for automotive, paint layer coating thickness measurement; integral type suitable for single-hand operation, large probe with large contact surface have better stability, users can get continuous, good repetitive and precise measurements. Separate type can provide several type probe, measure can be more flexibility. Product parameters Measuring range0~1250 um 0~50mil (other range may be specified) Resolution0.1 um (0~99.9um)/1 um (over 100um) Accuracy:1~3%n or 2.5 um or 0.1mil (whichever is the greater) Minimum measurement area6 mm Size120x63x25 mm Power supply2x1.5vaaa um-4 battery Weight90 g (not including batteries) Product accessories Standard accessoriesMain unit Calibration foils Substrate ( iron ) Substrate ( aluminium ) Carrying case Operation manual Optional accessories Usb data output Bluetooth data output Buying guide When you choose the model number of amittari instrument, the default is standard delivery. If you need other optional accessories, please tell our customer -service worker. The following three items are basic optional accessories choices Standard accessories+usb data output Standard accessories+bluetooth data output Bluetooth accessories Portable platstic case
Product Description The Anticorrosion Coating Thickness Gauge is a kind of portable measuring instrument, it can quickly, no damage andprecise coating, coating thickness measurement. Not only can be used in the laboratory, also can be used in the engineering field. Through the use of different measuring head, but also can meet the needs of a variety of measurement. Widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and testing field. Is the material protection professional necessary instruments. Product Feature * Digital backlit display gives exact reading with no guessing or errors. * Two measurement mode: Single and Continuous. * Wide measuring range and high resolution. * Manual or automatic shut down. * Use USB data output with connection PC * Provide Bluetooth data outputchoice. Product Parameters Range 0~12 mm (other range may be specified) Resolution 0.01mm / 0.1mm Product Accessories Standard Accessories Host Calibration Foils Substrate ( Iron ) Substrate ( Aluminium ) Carrying Case Operation Manual Optional Accessories USB data output Bluetooth data output Portable plastic case
YUSHI INSTRUMENTSï¼?We Are Manufacturer 20 years NDT experience,ISO, CE & RoHS certificated, this is how we keep superior quality and competitive offers for global valued customers Measuring Principle Eddy Current Method (NFe): measuring the thickness of non-conductive coatings on copper, aluminum, stainless steel and other non-ferromagnetic substrates, e.g. painting, varieties of anti-corrosion coating, powder spraying, plastic, rubber, synthetic material, oxide film and phosphate film, etc. Features Display: High Contrast Segment Liquid Crystal Display(LED Backlight) Measuring Range: 0-2000m Working Temperature: -10 ~ 50 Auto Power-off: Auto off after 3 minutes of inactivity Calibration Method: Zero calibration, One-Point and Two-point calibration Power Requirements: 2 AA size batteries, low-voltage indication function Size: 149mm X 73mm X 32mm (H x W x D) Weight: 200g including batteries Battery is not included
YUSHI INSTRUMENTS�We Are Manufacturer 20 years NDT experience,ISO, CE & RoHS certificated, this is how we keep superior quality and competitive offers for global valued customers Measuring Principle Magnetic Method (Fe): Measuring the thickness of non- magnetic coatings on steel, iron and other ferromagnetic metal substrates, e.g. painting, varieties of anti-corrosion coating, powder spraying, plastic, rubber, synthetic material, phosphate coating, chromium, zinc, Aluminum, tin and cadmium, etc. Features Display: High Contrast Segment Liquid Crystal Display(LED Backlight) Measuring Range: 0-10000μm Working Temperature: -10 ~ 50 Auto Power-off: Auto off after 3 minutes of inactivity Calibration Method: Zero calibration, One-Point and Two-point calibration Power Requirements: 2 AA size batteries, low-voltage indication function Size: 149mm X 73mm X 32mm (H x W x D) Weight: 200g including batteries Battery is not included
Display: 2.4QVGA(320�240)true color OLED screen, contrast 10000:1 Measuring Modes Interface-Echo Mode( I-E):for thick material Echo-Echo Mode (E-E): for the thin material and measure through the coating Multiple Echo Verify Mode (ME-E): All the thickness values have been checked through 3 to 9 times of echos, which makes the result more reliable and accurate Auto Mode: The instrument select the measuring mode automatically according to the different material being tested Measuring Range( Steel) Interface-Echo Mode: 0.06''- 1.06'' Echo-Echo Mode: 0.06''- 0.53'' Multiple Echo Verify Mode: 0.01''- 0.35'' Auto Mode: 0.01''-1.06'' Display Mode A-SCAN: Displays the whole RF echo or half-waveform after rectified B-SCAN: Real time B-Scan, displays the profile of the workpiece Big Thickness Value: The conventional display of the thickness value Min./Max. Capture: Display the current thickness value, Min. value and Max. value at the same time Difference/Thickness thinning rate: Display the difference between the real thickness value and the preset thickness value, and the percentage of the thinning value Gain:Real time continuously adjustable, adjustable range 41dB Measuring Resolution:0.0001inch Material VelocityRange:0.0197-0.3937in/us Units:Inch or Millimeter Language:Chinese, English, French, Germany, Japanese Power:2 AA size batteries, Operating time is more than 35 hours Working Temperature: 14°F ~122°F Size:6'' � 3'' �1.5''(H �W �D) Weight:280g including batteries Battery and Couplant are Prohibited Goods by Air Shipping by DHL/FedEx taking 3-5 days
0.001 inch (0.1mm) resolution,measuring range: 0.03'' to 12'' 128 x 64 pixel graphical LCD with EL backlight Stores 500 readings in 5 groups of 100 V- path correction, Alarm Mode and Minimum Capture Up to 200 hours with two 1.5V AA alkaline batteries (without backlight), AUTO-OFF after 5 minutes of inactivity Product Description Style:UM-1 YUSHI INSTRUMENTS We Are Manufacturer 20 years NDT experience,ISO, CE & RoHS certificated, this is how we keep superior quality and competitive offers for global valued customers This instrument can be widely used in the fields such as manufacturing, metal processing, chemistry and business inspecting for measuring the thickness of all sorts of materials where ultrasonic wave can spread through with a constant speed and get the reflection from the back side Operating Principle:P-E (pulse-echo) with dual-crystal probes Measuring Range:0.03'' to 12'' in standard mode Storage:5 arrays are divided to store 500 thickness values Repeatability:0.001'' Display Resolution: 0.001inch Units:Inch or Millimeter Update Rate:4Hz Material Velocity Range:0.0394 to 0.3937in/μs Measuring Limits of Tube(Steel): Φ20mm �? 3.0mm (PT-08 probe) Φ15mm �? 2.0mm (PT-06 probe) The measuring error is up to ± 0.001'' Measuring Error: Low limit to 0.4'': ±0.004'' 0.4'' to high limit: ± ± (1%H+0.001) inch Note: H is the actual thickness of the testing material Operating Time:Up to 200 hours with alkaline batteries (without backlight) Instrument Shut-off:AUTO OFF after 5 minutes of inactivity Power Requirements:Two 1.5V AA alkaline batteries (Warning with low battery voltage) Operating Temperature:14°F to 122°F , 4°F in special requirements Size:5.8'' X 2.9'' X 1.3''(H X W X D) Weight:7.4oz including batteries Battery and Couplant are Prohibited Goods by Air Shipping by DHL taking 3-5 days What�??s in the BOX? 1*Main Unit, 1*Probe, 1 * Carrying Case, 1* User Manual
The "AMTG-2" is a portable feeler gauge. It is used to measure the thickness of non-magnetic materials, such as plastic, glass, ceramic, aluminum, titanium, copper etc... The accuracy of the measurement is not affected by the shape of the samples. It’s designed by basing on the method of the Hall Effect. Simple and rapid measure as below: - Place the steel ball on one side of the sample and the probe on the opposite side - Move the sample and let the probe to be the tested position - The steel ball will be drawn by the probe automatically - The Hall Effect sensor on the probe measures the distance between the probe tip and the steel ball
With different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic metal substrate, as well as non-conductive coating on non-magnetic metal substrate. Five types of probes (F400, F1, F10, N1, CN02) are available for different application. F10 probe measures up to 10mm. Two measuring modes: single or continuous, changeable. Two calibration methods can be applied to the gauge; And the system error of the probe can be corrected with the basic probe calibration method. Measured values and user information are shown on a large, easy-to-read LCD. A display back light ensures easy reading of screen data in poorly-lit conditions. Measuring status indicator showing the measuring status. n. Measuring Principles The gauge adopts two thickness-measuring methods: magnetic induction method and eddy current method. insulating coatings on all non-ferrous metals and on austenitic stainless steels, e.g. paint, anodizing coatings, ceramics, etc. applied on aluminum, copper, zinc die-casting, brass, etc. Working Conditions Working temperature£º -10¡æ¡«£«50¡æ; Storage temperature£º-30¡æ¡«£«60¡æ; Relative humidity: ¡Ü90£¥; The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust. Configuration No. Item Quantity Remarks Standard Config. 1 Main unit 1 2 Probe 1 F1 or N1 3 Calibration Foils 5 PCS 4 Zero plate 1 Iron or Aluminum 5 Instrument case 1 6 Manual 1 7 Alkaline Battery 2 PCS AA size 8 Optional Config. 9 Other type of probes 10 DataPro software 1 On CD 11 USB cable 1 bjxhhd-tech.com sinharef@126.com
Capable of performing measurements on a wide range of material. Four transducer models. Probe-Zero function, Sound-Velocity-Calibration function. Two-Point Calibration function. Two work modes: Single point mode and Scan mode. Coupling status indicator showing the coupling status. Auto sleep and auto power off function to conserve battery life. Optional software to process the memory data on the PC. Optional thermal mini-printer to print the measured data via RS232 port CONFIGURATION No Item Quantity Note Standard Configuration 1 Main body 1 2 Transducer 1 Model: N05/90¡ã 3 Couplant Bottle 1 4 Instrument Case 1 5 Screwdriver 1 6 Alkaline battery 2 AA size 7 Operating Manual 1 8 Warranty Card 1 Optional Configuration 9 Transducer: N02 10 Transducer: N07 11 Transducer: HT5 12 Mini thermal printer 1 13 Print cable 1 14 DataPro for Thickness Gauge 1 For use on the PC 15 Communication Cable 1 APPENDIX A: TRANSDUCER SELECTION Model Freq MHZ Diam mm Measuring Range Lower limit Description N02 2.5 14 3.0mm¡«300.0mm£¨In Steel£© 40mm (in Gray Cast Iron HT200) 20 for thick, highly attenuating, or highly scattering materials N05 5 10 1.2mm¡«230.0mm£¨In Steel£© ¦µ20mm¡Á3.0mm Normal Measurement N05/90¡ã 5 10 1.2mm¡«230.0mm£¨In Steel£© ¦µ20mm¡Á3.0mm Normal Measurement N07 7 6 0.75mm¡«80.0mm £¨In Steel£© ¦µ15mm¡Á2.0mm For thin pipe wall or small curvature pipe wall measurement HT5 5 12 3¡«200mm £¨In Steel£© 30 For high temperature (lower than 300¡ãC) measurement. APPENDIX B: SOUND VELOCITY IN DIFFERENT MATERIALS Material Sound Velocity In/us m/s Aluminum 0.250 6340-6400 Steel, common 0.233 5920 Steel, stainless 0.226 5740 Brass 0.173 4399 Copper 0.186 4720 Iron 0.233 5930 Cast Iron 0.173-0.229 4400-5820 Lead 0.094 2400 Nylon 0.105 2680 Silver 0.142 3607 Gold 0.128 3251 Zinc 0.164 4170 Titanium 0.236 5990 Tin 0.117 2960 Epoxy resin 0.100 2540 Ice 0.157 3988 Nickel 0.222 5639 Plexiglass 0.106 2692 Polystyrene 0.092 2337 Porcelain 0.230 5842 PVC 0.094 2388 Quartz glass 0.222 5639 Rubber, vulcanized 0.091 2311 Teflon 0.056 1422 Water 0.058 1473 CONFIGURATION No Item Quantity Note Standard Configuration 1 Main body 1 2 Transducer 1 Model: N05/90¡ã 3 Couplant Bottle 1 4 Instrument Case 1 5 Screwdriver 1 6 Alkaline battery 2 AA size 7 Operating Manual 1 8 Warranty Card 1 Optional Configuration 9 Transducer: N02 10 Transducer: N07 11 Transducer: HT5 12 Mini thermal printer 1 13 Print cable 1 14 DataPro for Thickness Gauge 1 For use on the PC 15 Communication Cable 1 bjxhhd-tech.com sinharef@126.com
With different external probes, the gauge can be applied to measuring thickness of non-magnetic coating on magnetic metal substrate, as well as non-conductive coating on non-magnetic metal substrate. Five types of probes (F400, F1, F10, N1, CN02) are available for different application. F10 probe measures up to 10mm. Two measuring modes: single or continuous, changeable. Two calibration methods can be applied to the gauge; And the system error of the probe can be corrected with the basic probe calibration method. Measured values and user information are shown on a large, easy-to-read LCD. A display back light ensures easy reading of screen data in poorly-lit conditions. Measuring status indicator showing the measuring status. The gauges¡¯ user-friendly measuring system permits automatic storage of up to 1000 readings in one memory matrix for later statistical evaluation. Measuring Principles The gauge adopts two thickness-measuring methods: magnetic induction method and eddy current method. insulating coatings on all non-ferrous metals and on austenitic stainless steels, e.g. paint, anodizing coatings, ceramics, etc. applied on aluminum, copper, zinc die-casting, brass, etc. Working Conditions Working temperature£º -10¡æ¡«£«50¡æ; Storage temperature£º-30¡æ¡«£«60¡æ; Relative humidity: ¡Ü90£¥; The surrounding environment should avoid of vibration, strong magnetic field, corrosive medium and heavy dust. Configuration No. Item Quantity Remarks Standard Config. 1 Main unit 1 2 Probe 1 F1 or N1 3 Calibration Foils 5 PCS 4 Zero plate 1 Iron or Aluminum 5 Instrument case 1 6 Manual 1 7 Alkaline Battery 2 PCS AA size 8 Optional Config. 9 Other type of probes 10 DataPro software 1 On CD 11 USB cable 1
The model MT160 is a digital ultrasonic thickenss gauge. Based on the same operatinfg principles as SONAR, the instrument is capable of measuring the thickness of various materials with accuracy as high as 0.01 /0.1mm. It is suitable for a variety of metallice and non-metallic materials. Capable of performing measurements on a wide range of material, including metals, plastic, ceramics, composites, epoxies, glass and other ultrasonic wave well-conductive materials. Transducer models are available for special application, including for coarse grain material and high temperature applications. CONFIGURATION No Item Quantity Note Standard Configuration 1 Main body 1 2 Transducer 1 Model: N05/90¡ã 3 Couplant Bottle 1 4 Instrument Case 1 5 Alkaline battery 2 AA size 6 Operating Manual 1 7 Warranty Card 1 8 Optional Configuration 9 Transducer: N02 10 Transducer: N07 11 Transducer: HT5 12 Mini thermal printer 1 13 Print cable 1 14 DataPro for Thickness Gauge 1 For use on the PC 15 Communication Cable 1 bjxhhd-tech.com sinharef@126.com
Used for measuring thickness and corrosion of pressure vessels, chemical equipment, boilers, oil storage tanks, etc.In industries of petroleum, shipbuilding, power station, and machine manufacturing. Model: tm8812 tm8812c Measuring range (metric/imperial): 1.0-200mm, 0.05-8inch Operating principle: ultrosonic Materials measured: any hard materials, including steel, cast iron, aluminum, red copper, brass, zinc, quartz glass, polyethylene, pvc, gray cast iron, nodular cast iron and other materials Sound velocity: 500-9000m/s Lower limit steel pipes: 15x2.0mm, 20x3.0mm determined by the transducer Calibration block: included Resolution: 0.1mm(tm8812c 0.01mm) Accuracy: (0.5%n+0.1) Rs232c interface: with rs232c Power supply: 4x1.5v aaa (um-4)battery Battery indicator: low battery indicator Operating conditions:0-+45(32-104), 90%rh Dimensions: 120x62x30mm Weight: 164g(not including battery) Optional accessories: 6m6mm thin material probe:measuring range(steel): 1.0 50.0mm operating temperature: -10~+60 5m12high temperature probe: measuring range(steel): 1.0~225.0mm(normal temperature) measuring range(steel): 4.0~100.0mm (high temperature) operating temperature: -10~+300.
Application: Used for measuring thickness and corrosion of pressure vessels, chemical equipment, boilers, oil storage tanks, etc.In industries of petroleum, shipbuilding, power station, and machine manufacturing. Model: tm8812 tm8812c Measuring range (metric/imperial): 1.0-200mm, 0.05-8inch Operating principle: ultrosonic Materials measured: any hard materials, including steel, cast iron, aluminum, red copper, brass, zinc, quartz glass, polyethylene, pvc, gray cast iron, nodular cast iron and other materials Sound velocity: 500-9000m/s Lower limit steel pipes:15x2.0mm,20x3.0mm determined by the transducer Calibration block: included Resolution: 0.1mm(tm8812c 0.01mm) Accuracy: ¡à(0.5%n+0.1) Rs232c interface: with rs232c Power supply: 4x1.5v aaa (um-4)battery Battery indicator: low battery indicator Operating conditions:0-+45(32-104), 90%rh Dimensions: 120x62x30mm Weight: 164g(not including battery) Optional accessories: 6m6mm thin material probe:measuring range(steel): 1.0 50.0mm operating temperature: -10~+60 5m12high temperature probe: measuring range(steel): 1.0~225.0mm(normal temperature) measuring range(steel): 4.0~100.0mm (high temperature) operating temperature: -10~+300.
Detailed Product Description: Ultrasonic thickness gauge Small, portable, high reliability, applicable to the severe operating environment like anti-vibration LK300 ultrasonic thickness gauge: 1. Suitable for measuring metal (such as steel, cast iron, aluminum, copper, etc.), plastic, ceramic, glass, glass fiber and other any good conductors of ultrasonic thickness. 2. Can be equipped with different frequencies, different sizes of crystal double probe usage. 3. With probe zero calibration and two calibration function, can automatic correct the system error. 4. The known thickness can set back sound velocity, in order to improve the accuracy of measurement. 5. Coupled state with prompt functions. 6. With EL backlit, convenient in use in dim light. 7. With dump energy instruction function, can real-time display battery remaining power. 8. Auto dormancy, shutdown and auto power etc. saving function. 9. With RS232 interface and can easily and quickly exchange data with PC. Can be connected to the micro printer (manufacturer designated models) print measurement the reports. 10. Can choose equipped with computer software, with measured results, measured storage management, measured statistical analysis values, printing measured report etc. rich functions. 11. Small, portable, high reliability, applicable to the severe operating environment like anti-vibration, anti-shock and electromagnetic interference(EMI). Technical parameter: Display Method: High-contrast LCD display code segment, high-brightness EL backlight; Measurement Range: (0.75 ~ 300) mm (steel), metric and imperial free conversion; Sound Velocity Range: (1000 ~ 9999) m / s: Resolution: 0.1mm/0.01mm optional Indication Accuracy: about(0.5% H +0.05) mm; H for the actual thickness of the tested object Measuring cycle: single-point measurements per second four times, 10 times per second scan mode; Storage Capacity: can store 20 groups (each up to 100 measurements) thickness measurement data Operating modes: a single point thickness measurement and scan thickness measuring two kinds of thickness mode Unit System: Metric or Imperial (optional) Operating voltage: 3V (2 # AA size alkaline batteries) Continuous working time: more than 100h (not open backlight pm) Communication Interface: RS232, with micro-printer or PC connection Dimensions: 150mm ¡Á 73mm ¡Á 31 mm Total Weight: 185g. Dimensions: 150mm ¡Á 73mm ¡Á 31 mm Total Weight: 185g Al-alloy case.
Ultrasonic thickness gauge 101H,103H Features: According to the principle of ultrasonic pulse reflect, precision measuring all sorts of plank and various processing parts. Widely used in petroleum, chemical, metallurgy, shipbuilding, aviation and navigation, etc. Automatic check zero, correct the system error. Linear automatic compensation, using single-chip microcomputer software correct probe error and with high accuracy. Technical parameter: Measuring scope: 1.2 mm - 220mm (Steel, conventional detector) Or 0.8mm-50mm (Small tube thickness probe) 4 digit LCD display, can backlit work Velocity adjustable scope: 101H: 500-9999m/s, continuous adjustable 103H : 5900m/s, un-adjustable Material thickness can measured velocity. Measurement error: +/- (0.5% H + 0.1) mm Provide coupling instructions, through the observe stable state can know whether coupling normal. Power supply: a no.5 batteries Instructions: when the power supply voltage owe
Used for measuring thickness and corrosion of pressure vessels, chemical equipment, boilers, oil storage tanks, etc. In industries of petroleum, shipbuilding, and machine manufacturing. Tm-8812, tm-8811, can measure any hard materials, including steel, cast iron, aluminum, red copper, brass, zinc, quartz glass, polyethylene pvc, gary cast iron, nodular cast iron and other materials. Tm-8810, can measure only 11 types of materials, including steel, cast-iron, aluminum, red copper, brass, zinc, quartz glass, polyethylene, pvc, gray cast iron, nodular cast iron. Dimensions: 160x68x32mm