Our company into this industry for many years, have rich experiences. We own mature processing technology , perfect inspection equipments and advanced management. It is worth mentioning that our products has obtained the national patent. Now our production line has annual capacity of 500, 000 pieces of oxygen sensor No mind
Oxygen sensor Oxygen sensor is a kind of metallurgy detection probe which is designed to measure the oxygen content and temperature of the molten steel fast, accurately and directly. 1. Application: used for primary melting furnace, lf and rh furnaces and so on, oxygen probes measure oxygen activity of the molten steel and the oxygen activity of the molten steel in the treating process, which can guarantee the deoxidizer addition, shorten the refining time, help to develop new varieties, improve technology, and promote steel purity. 2. Main features and range of application: Oxygen sensor has three types: 1)oxygen sensor for high ppm 2)oxygen sensor for low ppm . 3)oxygen sensor for ultra-low ppm.
Luminox ppm fluorescence o2 sensors features * fluorescenceâ??based optical technology * contains no hazardous materials; rohs & reach compliant * factory calibrated * high accuracy * maintenance free * long life, non-depleting technology - can be stored in any oxygen % Luminox ppm fluorescence o2 sensors benefits * low power, long life due to non-depleting sensing principle * compact footprint Luminox ppm fluorescence o2 sensors technical specifications Supply voltage (vs) : 8-30v dc Supply current (ls) :
Zirconia o2 sensors Probe series - long housing Features * zirconium dioxide (zro2) sensing elements * long life, non-depleting technology * integral heating element * high accuracy * requires an external interface board to operate Benefits * no reference gas required * no need for temperature stabilisation * two lengths available; 220mm and 400mm Technical specifications Heater voltage Operating: 4v dc ± 0.1v dc (1.7a) Standby: 1.65v dc (0.7a) Pump impedance at 700'c: < 6k Permissible gas temperature Standard temperature: -100'c to +250'c High temperature: -100'c to +400'c Gas flow rate: 0 - 10 m/s Repetitive permissible acceleration: 5g Incidental permissible acceleration: 30g Output values Oxygen pressure range: 2mbar - 3bar max Accuracy: 5 mbar max Internal operational temperature: 700'c Response time (10 - 90% step): < 15s Warm up time (prior to sensor operation): 100s Warm up time (from stand by): 20s Output stabilisation time: ~ 180s
O2-C2 Oxygen Sensor (O2 Sensor) Description Alphasense Oxygen sensors use capillary flow control. Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications. Standard galavanic sensors use lead for greatest reliability but fixed lifetime. O2-C2 Oxygen Sensor size: 20mm diameter, extra height allows additional filter material when measuring combustion gases O2-C2 Oxygen Sensor (O2 Sensor) Specifications: * Output: 80 to 120A @ 20.9% O2 * Response time t90: < 50(s) from 20.9% to 0% O2 * Linearity: -0.6 % O2 deviation @ 10% O2 * Operating life: > 24 months * Temperature range : -30 to 55'C * Pressure range: 80 to 120 kPa * Humidity range: 5 to 95 % rh continuous * Weight: < 18 g
O2-A3 Oxygen Sensor O2 Sensor Description Alphasense Oxygen sensors use capillary flow control. Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications. Standard galavanic sensors use lead for greatest reliability but fixed lifetime. O2-A3 Oxygen Sensorsize: 20mm diameter, the industry standard size for portable gas detectors O2-A3 Oxygen Sensor O2 Sensor Specifications * Output: 60 to 85 μA @ 22'C, 20.9% O2 * Response time t90 : < 15 (s) from 20.9% to 0% O2 * Operating life: > 36 months * Temperature range : -30 to 55 'C * Pressure range : 80 to 120 kPa * Humidity range : 5 to 95 % rh continuous * Height : 17.4 mm (including foam ring) * Weight: < 16 g
1 wire weight:0.13
O2-A3 Oxygen Sensor O2 Sensor Description Alphasense Oxygen sensors use capillary flow control. Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications. Standard galavanic sensors use lead for greatest reliability but fixed lifetime. O2-A3 Oxygen Sensorsize: 20mm diameter, the industry standard size for portable gas detectors O2-A3 Oxygen Sensor O2 Sensor Specifications * Output: 60 to 85 μA @ 22â??, 20.9% O2 * Response time t90 : < 15 (s) from 20.9% to 0% O2 * Operating life: > 36 months * Temperature range : -30 to 55'C * Pressure range : 80 to 120 kPa * Humidity range : 5 to 95 % rh continuous * Height : 17.4 mm (including foam ring) * Weight: < 16 g
Paraflex UNI-R Multistrand FR PVC Insulated Cu. Paraflex Multistrand FR/FRLS PVC insulated Cu. Paraflex round multicore Flexible PVC insulated Cu. Paraflex submersible (3-coreflat) and UNI-R Submersible PVC Insulated Cu. Paraflex Aluminum Unarmored, Single Core twin flat 3 core and 4 core round solid and XLPE Aluminum Twin flat (Heavy Duty) Paraflex PVX VIR Copper Cabales. Paraflex Co-Axial wires. Paraflex Oxygen Free speaker and camera wire. Paraflex twin flat and copper flexible cables. Paraflex PVC FR tape. to 630 sq.mm core, 2 core, 3 core, 3.5 core and 4 core both in Al & Cu. Under IS: 7098 (Part 1), IS: 1554 (Part 1). Aerial Bunch cable IS: 14255 range 16 sq.mm to 95 sq.mm. PVC Rigid Conduits IS 9537 Part-3, 2003
Quality Copper Cathode Grade A Purity Cathode Copper 99.99% Copper Cathode/copper Cathodes Price Copper Cathode Grade A Purity: Purity 99.97% - 99.99% Min Specifications Competitive & Reliable Price Excellent Customer Service Outstanding Delivery Reliability 1. Typical Specifications - Product: Copper Cathodes Grade A (electrolytic Copper Grade) (lme Standards) Standard Cu Cathode-1, Purity 99.99% Dimension: 914mm X 914mm X 12mm (lme Standards) Weight Of Each Sheet: 125kgs (+/- 1%) Net Weight Of Each Pallet: 2mts (+/- 1%) Min. Weight In Each Container: 20mts Approx. Gross Weight Of Each Container: 22.20mts Approx. Packing: Palletized Banded By Aluminum Bands 2. Chemical Composition Copper (cu) : Min% 99.99% Other Materials May Be Present Which Are Described Below: Oxygen O2 -- Sulfur S:.............................. 4 Ppm Iron Fe:..............................2 Ppm Silver(argent) Ag::..............................10 Ppm Lead Pb:..............................0.2 Ppm Nickel Ni:..............................0.2 Ppm Selenium Se:..............................0.3 Ppm Antimony Sb:..............................0.1 Ppm Silica Si:..............................0.3 Ppm Cobalt Co:..............................0.2 Ppm Arsenic As:..............................0.1 Ppm Bismuth Bi:..............................0.1 Ppm Manganese Mn:..............................0.1 Ppm Tellurium Te:.............................. 0.05 Ppm Aluminum Al:.............................. 0.5 Ppm Magnesium Mg:.............................. 0.4 Ppm Zinc Zn:.............................. 0.4 Ppm Packaging: Steel Belt Packed, Single Bundle Weighs About 2500 Kilograms. Hts Code 7403.11 Price = Us$ 5,400 Cif Origin: South Africa Min Order: 50 Tons
COMMODITY: COPPER CATHODES SHEETS, GRADE 'A' Cu 99.99%, NON-REGISTERED LME, ORIGIN : 1.ZAMBIA 2. THE COPPER CATHODES TRAVEL FROM BONDED WAREHOUSE OF SELLER TO BONDED WAREHOUSE STENWEG IN NDOLA ZAMBIA, SUPPLIES: 1 TRIAL SHIPMENT FOR 1,000 MT (+/- 5%) AND UP TO 10,000 MT (+/- 5%) EVERY 30 DAYS FOR A MAXIMUM OF 36 CONSECUTIVE MONTHS. DELIVERY : THE GOODS WILL BE DELIVERED TO THE BUYER IN SITUATION BONDED WAREHOUSE STEINWEG, NDOLA ZAMBIA IN PALLETS BELT WITH 2 MT Approximately Each Pallet. Documents : the Documets Scaned Issued at Name of Buyer Skr (Safe Keeping Record) by Bonded Warehouse Steinweg Nodola Zambia and Certificate of Quality and Quantity to Be Issued by Bv, Alex Steward /ccic or Similar International. They Will Be Sent to the Buyer Within 12/15 Days L/c at Seller Bank Unit Price : Lme -11% (Lme=89%) Usd/mt Since Bonded Warehouse Steinweg, Zambia. Payment Terms: L/c 100% at Sight Against Shipping Documents. HS CODE : 74.03.11.00 SPECIFICATIONS : Copper Cu 99.97-99.99% - REJ.:
1. Commodity: Continuously Cast And Rolled Electrolytic Copper Wire Rods For Electrical Conductors. 2. Origin & Loading Port: China. Loading: Tianjin Port, China Or Similar, At Option Of The Seller. 3. Quality: See Attached 4. Presentation: Continued Rolls Of 5 Mt Approx. Introduced In 20 Foot Containers, With 22/23 Net Mt, Each One. 5. Quantity: 500 Mt (+/- 5%) Expandable Up To 3,000 Mt (+/- 5%) Every 30 Days. Commercial Agreement Of 13 Months For 36,500 Mt (+/- 5%) Minimum. 6. Price: Lme-6% Usd / Mt, Cif: Any Asian Port. Incoterms 2010. The Price Of Each Shipment Will Be Fixed On The Date Of Issue Of The B / L In The Port Of Origin. 7. Delivery: The First Shipment Will Be Shipped In Origin 30/35 Days After Receiving The L / C (mt700 / 710) In The Seller's Bank And Whose Text Is Accepted By The Seller. For The Following Scheduled Shipments, It Will Be Performed In The Same Way. 8. Method Of Payment: L / C (mt 700/710) Irrevocable, Non-transferable, Non-divisible, Payable At Sight At Origin Against Delivery Of The Following Documents: 9. Documents: 1. Signed Commercial Invoice. 2. Packing List; 3. Sgs/bv/ccic Certificate Of Quality And Quantity. 4. Certificate Of Origin Issued By The Chamber Of Commerce In Origin; 5. Bill Of Landing Marked "freight Prepayd"; 6. Certificate Of Insuranc Hs Code 7408 Specifications: Copper Cu 99.90-99.96% - Rej.:
Thank you for purchasing and using our company's ultrasonic oxygen concentration / flow sensor. 1, please carefully read the instructions and fully understand the contents of the sensor after operation and maintenance. Improper use may cause damage to the sensor. (no violent impact and falling ground) 2, without the consent of the company, it is strictly prohibited to alter the structure and components of the sensor without authorization. The company is not responsible for any personal safety incidents or sensor abnormalities caused by unauthorized alterations. 3, the specifications and instruction contents of this sensor may be changed due to the technical improvement of the product. 4, this instruction manual must be handed to the actual user of the sensor and stored in it, and placed at any time where the actual user of the sensor can access it. 5, the company has the right to interpret the instructions for the sensor. 2ã??technical parameter Measurement parameters measuring method range Resolution accuracy FLOW Ultrasonic 0-10L/min 0.1L �±0.2L/min O2 Ultrasonic 20.5%-95.6% 0.1% �±1.8%FS 5-45â?? Note: the range can be customized according to customer requirements. Sample gas requirements Water removal (no condensation); dust filtration (
We have available following Ships spares for Sale: Product-Oxyzen Sensor Type-RGD90 Part no-S01-169
Features: oxygen pressure range 2 mbar - 3bar zirconium dioxide (zro2 ) sensing elements non-consumption technology integral heating element no need for temperature stabilisation no reference gas required high accuracy linear output signal operates with external interface boards Specifications Heater supply* Full porous cap 4.35v dc +/- 0.1v dc (1.85a) Stand by 2 v dc (0.85a)
Do sensor dissolved oxygen sensor water quality control sensor kds-25b Model number: kds-25b Description The gs yuasa dissolved oxygen sensor kds-25b is a unique Galvanic cell type sensor which was developed for water quality Control. Its most notable features are long life expectancy and it Is not influenced by co2. Features: * long life * virtually no influence from co2 * no external power supply required for sensor Operation * no warmup time is required Applications: * water quality control
Do1200 and do1200tc dissolved oxygen sensors Item no.: do1200/h, do1200/t, do1200tc/h, do1200tc/t, 971598, 971598tc Reliable galvanic sensing technology Compact 12mm design For portable, laboratory or on-line use Optional integral atc element Easy to use pre-membraned replacement caps The do1200 and do1200tc feature dependable galvanic technology. No warm up period is required. Sensors are supplied with fast responding hdpe membrane caps for portable or lab use. Optional ptfe membrane caps are available for on-line or heavy uv exposure applications. Fill solution is replaceable when required. The do1200 is supplied without internal temperature compensation. The do1200tc can be supplied with a variety of user defined atc elements. Standard cable length is 2.5 feet with a tinned lead termination. Longer cable lengths and connectors are available for an additional charge. For on-line use, our fc75p 3/4 inch in-line fitting may be ordered to provide for mounting into 3/4 inch fnpt threaded tees. Do1200 laboratory dissolved oxygen sensor specifications Range: 0-20 mg/l Body material: epoxy and noryl Max temperature: 50 degrees c Saturation output: Hdpe = 47mv +/- 9mv, Ptfe = 33mv+/-9mv Pressure: 0-100 psig (7.5 bar) Calibration: single point in air Response time: after equilibration, hdpe 1 minute for 2mv, ptfe 2 minutes for 2mv
We specialise in providing a comprehensive range of auto parts & motor parts. Our commitment is to offer high-quality products that ensure optimal performance, safety, and reliability for all types of vehicles Here's a list of some of the auto parts we provide: 1. Engine Components: - Spark plugs - Oil filters - Air filters - Belts and hoses - Engine mounts - Timing belts/chains - Pistons & Rings 2. Braking System Parts: - Brake pads - Brake rotors/discs - Brake calipers - Brake lines - Master cylinders - Brake fluid 3. Suspension and Steering Parts: - Shock absorbers/struts - Control arms - Tie rod ends - Ball joints - Steering racks - Power steering pumps 4. Electrical Components: - Batteries - Alternators - Starters - Ignition coils - Wiring harnesses - Sensors (Oxygen sensors, ABS sensors, etc.) 5. Cooling System Parts: - Radiators - Water pumps - Thermostats - Radiator hoses - Cooling fans - Heater cores 6. Exhaust System Parts: - Exhaust manifolds - Catalytic converters - Mufflers - Exhaust pipes - Oxygen sensors - Gaskets and seals 7. **Transmission and Drivetrain Parts:** - Transmission fluid - Clutch kits - CV joints - Axles - Transmission mounts - Differential parts 8. Interior and Exterior Accessories: - Headlights - Tail lights - Mirrors - Wiper blades - Floor mats - Seat covers 9. Performance Upgrades: - Cold air intakes - Exhaust headers - Performance chips/tuners - Suspension lift kits - Turbochargers - High-performance brakes 10. Maintenance and Service Items: - Oil and lubricants - Filters (air, oil, fuel) - Sealants and adhesives - Cleaning and detailing products - Tools and equipment - Diagnostic scanners Our goal is to provide top-notch products, exceptional customer service, and competitive prices to ensure your satisfaction.
OEM: 036906262t TB NO.: 2912502A Sensor Type: 5 wire wideband oxygen sensor Fitting: For SEATIBIZA IV (6L1) (2002/02 - 2009/11) For SEATCORDOBA (6L2) (2002/09 - 2009/11) For SKODAFABIA (6Y2) (1999/08 - 2008/03) For SKODAFABIA Combi (6Y5) (2000/04 - 2007/12) For SKODAFABIA Saloon (6Y3) (1999/10 - 2007/12) For POLO (9N_) (2001/10 - 2012/01) For POLO Saloon (9A4) (2002/09 - /)
PO2-2x Percent Oxygen Sensor (O2 sensor) General Purpose % O2 measurement when CO2 > 0.1%. Use when acid gases are present (CO2, HCl, HCN, etc.) PO2-2x Percent Oxygen Sensor (O2 sensor) Direct Replacement Guide Analytical Industries: XLT-11-15 Teledyne: A-3, A-5 PO2-2x Percent Oxygen Sensor (O2 sensor) Specifications: Sensor Technology: Micro Fuel Cell Signal Output: 105 - 260uA Measuring Range: 0 - 100 Percent Response Time T90: 7 Seconds Accuracy Full Scale: ± 1% of Signal Repeatability F.S.: ±0.5% Temp Coefficient: 2.54 %/ºC Operating Temp: 0 to 50ºC Storage Temp: 0 to 45ºC Recommended Flow: 0.5 - 2 SCFH Humidity: 0 - 100% RH (Non - Condensing) Expected Life: 12 - 15 Months Storage: 6 Months Warranty: 9 Months PCB Connection: Center Foil Negative Outer Foil Positive