O2-A3 Oxygen Sensor O2 Sensor Description
Alphasense Oxygen sensors use capillary flow control.
Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications.
Standard galavanic sensors use lead for greatest reliability but fixed lifetime.
O2-A3 Oxygen Sensorsize:
20mm diameter, the industry standard size for portable gas detectors
O2-A3 Oxygen Sensor O2 Sensor Specifications
* Output: 60 to 85 μA @ 22â??, 20.9% O2
* Response time t90 : < 15 (s) from 20.9% to 0% O2
* Operating life: > 36 months
* Temperature range : -30 to 55'C
* Pressure range : 80 to 120 kPa
* Humidity range : 5 to 95 % rh continuous
* Height : 17.4 mm (including foam ring)
* Weight: < 16 g
O2-A3 Oxygen Sensor O2 Sensor Description Alphasense Oxygen sensors use capillary flow control. Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications. Standard galavanic sensors use lead for greatest reliability but fixed lifetime. O2-A3 Oxygen Sensorsize: 20mm diameter, the industry standard size for portable gas detectors O2-A3 Oxygen Sensor O2 Sensor Specifications * Output: 60 to 85 μA @ 22'C, 20.9% O2 * Response time t90 : < 15 (s) from 20.9% to 0% O2 * Operating life: > 36 months * Temperature range : -30 to 55 'C * Pressure range : 80 to 120 kPa * Humidity range : 5 to 95 % rh continuous * Height : 17.4 mm (including foam ring) * Weight: < 16 g
O2-M2 Oxygen Sensor Description Alphasense Oxygen sensors use capillary flow control. Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications. Standard galavanic sensors use lead for greatest reliability but fixed lifetime. Specifications * Output: 80 to 120 uA @ 20.9% O2 * Response time t90: < 15 (s) from 20.9% to 0% O2 * Linearity: 0.6 % O2 deviation @ 10% O2 * Operating life: > 24 months *Temperature range: -30 to 55 'C * Pressure range: 80 to 120 kPa * Humidity range: 5 to 95 % rh continuous * Diameter: 20.0 mm (including label) * Heigh: 17.4 mm (including foam ring) * Weight: < 16g
Our most advanced intelligent spot detectors, multi-criteria/multi-sensor devices use multiple sensors to detect various conditions in an environment sensing a wider range of fires with greater accuracy. Features & Benefits: Multi-Criteria/Multi-Sensor smoke detection Unique ability to detect major elements of a fire Highest nuisance alarm immunity Advanced algorithms interpret and respond to multiple inputs
Features * oxygen pressure range 2 mbar - 3bar * zirconium dioxide (zro2 ) sensing elements * non-consumption technology * integral heating element * no need for temperature stabilisation * no reference gas required * high accuracy * linear output signal * operates with external interface boards Specifications Heater voltage: Porous cap (15mm): 4.35v dc +/- 0.1v dc (1.85a) Stand by: 2v dc (0.85a) Pump resistance @ 700'C: < 6kOhm Permissible gas temperature: -100 to 250C Gas flow rate: 0 to 10 m/s Repetitive permissible acceleration: 5 g Incidental permissible acceleration: 30 g
O2-a2 oxygen sensor Performance Output î¼a @ 20.9% o2 80 to 120 Response time t90 (s) from 20.9% to 0% o2 < 15 Zero current î¼a in n2 < 2.5 Linearity % o2 deviation @ 10% o2 0.6 Lifetime Output drift % change in output @ 3 months < 1 Operating life months until 85% original output of 20.9% o2 > 24 Environmental Humidity sensitivity % o2 change: 0% to 95% rh @ 40â?? < 0.7 Co sensitivity % (change o2 reading) / % co2 @ 5% co2 0.1 Pressure sensitivity (% change of output)/(% change of pressure) @ 20kpa < 0.1 Key specifications Temperature range â?? -30 to 55 Pressure range kpa 80 to 120 Humidity range % rh non-condensing (0 to 99% rh short term) 5 to 95 Storage period months @ 3 to 20â?? (store in sealed pot, open circuit) 6 Load resistor î© (recommended) 47 to 100 Diameter mm (including label) 20.0 Height mm (including foam ring) 17.4 Weight g < 16 -
Thank you for purchasing and using our company's ultrasonic oxygen concentration / flow sensor. 1, please carefully read the instructions and fully understand the contents of the sensor after operation and maintenance. Improper use may cause damage to the sensor. (no violent impact and falling ground) 2, without the consent of the company, it is strictly prohibited to alter the structure and components of the sensor without authorization. The company is not responsible for any personal safety incidents or sensor abnormalities caused by unauthorized alterations. 3, the specifications and instruction contents of this sensor may be changed due to the technical improvement of the product. 4, this instruction manual must be handed to the actual user of the sensor and stored in it, and placed at any time where the actual user of the sensor can access it. 5, the company has the right to interpret the instructions for the sensor. 2ã??technical parameter Measurement parameters measuring method range Resolution accuracy O2 Ultrasonic 20.5%-95.6% 0.1% �±1.8%FS 5-45â?? Note: the range can be customized according to customer requirements. Sample gas requirements Water removal (no condensation); dust filtration (
Features * oxygen pressure range 2 mbar - 3bar * zirconium dioxide (zro2 ) sensing elements * non-consumption technology * integral heating element * no need for temperature stabilisation * no reference gas required * high accuracy * linear output signal * operates with external interface boards * pcb mountable Specifications Heater supply* Porous lid cap 4vdc +/- 0.1vdc (1.7a) Stand by 1.65vdc (0.7a) Full porous cap 4.35v dc +/- 0.1v dc (1.85a) Stand by 2v dc (0.85a)
Features * oxygen pressure range 2 mbar - 3bar * zirconium dioxide (zro2 ) sensing elements * non-consumption technology * integral heating element * no need for temperature stabilisation * no reference gas required * high accuracy * linear output signal * operates with external interface boards * 80mm, 220mm and 400mm probes available Specifications Heater supply* Porous lid cap 4v dc +/- 0.1v dc (1.7a) Stand by 1.65v dc (0.7a) Full porous cap 4.35v dc +/- 0.1v dc (1.85a) Stand by 2v dc (0.85a)
Honeywell BW Solo is a easy to service single-gas detector with BLE connectivity that provides real-time visibility into the status and safety of hazardous-area workers, helping companies respond faster, more knowingly and decisively to safety incidents. The first single-gas detector with the 1 Series sensor for CO, H2S and O2 Features & Benefits: User-friendly operation, Easy-to-read display for multiple languages, Lightweight convenience, Ease of maintenance, Serviceability, The new 1-Series sensor for enhanced reliability, Connected Bluetooth Low Energy (BLE) capabilities.