We have available following Ships spares for Sale:
Product-Oxyzen Sensor
Type-RGD90
Part no-S01-169
Our company into this industry for many years, have rich experiences. We own mature processing technology , perfect inspection equipments and advanced management. It is worth mentioning that our products has obtained the national patent. Now our production line has annual capacity of 500, 000 pieces of oxygen sensor No mind
1 wire weight:0.13
Features: oxygen pressure range 2 mbar - 3bar zirconium dioxide (zro2 ) sensing elements non-consumption technology integral heating element no need for temperature stabilisation no reference gas required high accuracy linear output signal operates with external interface boards Specifications Heater supply* Full porous cap 4.35v dc +/- 0.1v dc (1.85a) Stand by 2 v dc (0.85a)
Do sensor dissolved oxygen sensor water quality control sensor kds-25b Model number: kds-25b Description The gs yuasa dissolved oxygen sensor kds-25b is a unique Galvanic cell type sensor which was developed for water quality Control. Its most notable features are long life expectancy and it Is not influenced by co2. Features: * long life * virtually no influence from co2 * no external power supply required for sensor Operation * no warmup time is required Applications: * water quality control
Do1200 and do1200tc dissolved oxygen sensors Item no.: do1200/h, do1200/t, do1200tc/h, do1200tc/t, 971598, 971598tc Reliable galvanic sensing technology Compact 12mm design For portable, laboratory or on-line use Optional integral atc element Easy to use pre-membraned replacement caps The do1200 and do1200tc feature dependable galvanic technology. No warm up period is required. Sensors are supplied with fast responding hdpe membrane caps for portable or lab use. Optional ptfe membrane caps are available for on-line or heavy uv exposure applications. Fill solution is replaceable when required. The do1200 is supplied without internal temperature compensation. The do1200tc can be supplied with a variety of user defined atc elements. Standard cable length is 2.5 feet with a tinned lead termination. Longer cable lengths and connectors are available for an additional charge. For on-line use, our fc75p 3/4 inch in-line fitting may be ordered to provide for mounting into 3/4 inch fnpt threaded tees. Do1200 laboratory dissolved oxygen sensor specifications Range: 0-20 mg/l Body material: epoxy and noryl Max temperature: 50 degrees c Saturation output: Hdpe = 47mv +/- 9mv, Ptfe = 33mv+/-9mv Pressure: 0-100 psig (7.5 bar) Calibration: single point in air Response time: after equilibration, hdpe 1 minute for 2mv, ptfe 2 minutes for 2mv
Viamed oxygen Sensor R-17MED R-22MED R-23V Equivalent to: AII: PSR-11-917-J PSR-11-917-J2 PSR-11-917-J3 PSR-11-917-J7 City :MOX-2 Envitec:OOM102-1 GMS:GO-15 ITG :M15 Maxtec: MAX-7
OEM: 036906262t TB NO.: 2912502A Sensor Type: 5 wire wideband oxygen sensor Fitting: For SEATIBIZA IV (6L1) (2002/02 - 2009/11) For SEATCORDOBA (6L2) (2002/09 - 2009/11) For SKODAFABIA (6Y2) (1999/08 - 2008/03) For SKODAFABIA Combi (6Y5) (2000/04 - 2007/12) For SKODAFABIA Saloon (6Y3) (1999/10 - 2007/12) For POLO (9N_) (2001/10 - 2012/01) For POLO Saloon (9A4) (2002/09 - /)
O2-M2 Oxygen Sensor Description Alphasense Oxygen sensors use capillary flow control. Unlike partial pressure oxygen sensors, they have good pressure and temperature dependence, making them the best choice in safety applications. Standard galavanic sensors use lead for greatest reliability but fixed lifetime. Specifications * Output: 80 to 120 uA @ 20.9% O2 * Response time t90: < 15 (s) from 20.9% to 0% O2 * Linearity: 0.6 % O2 deviation @ 10% O2 * Operating life: > 24 months *Temperature range: -30 to 55 'C * Pressure range: 80 to 120 kPa * Humidity range: 5 to 95 % rh continuous * Diameter: 20.0 mm (including label) * Heigh: 17.4 mm (including foam ring) * Weight: < 16g
Do1200 and do1200tc dissolved oxygen sensors Item no.: do1200/h, do1200/t, do1200tc/h, do1200tc/t, 971598, 971598tc Do1200 dissolved oxygen sensor features * reliable galvanic sensing technology * compact 12mm design * for portable, laboratory or on-line use * optional integral atc element * easy to use pre-membraned replacement caps Do1200 dissolved oxygen sensor description The do1200 and do1200tc feature dependable galvanic technology. No warm up period is required. Sensors are supplied with fast responding hdpe membrane caps for portable or lab use. Optional ptfe membrane caps are available for on-line or heavy uv exposure applications. Fill solution is replaceable when required. The do1200 is supplied without internal temperature compensation. The do1200tc can be supplied with a variety of user defined atc elements. Standard cable length is 2.5 feet with a tinned lead termination. Longer cable lengths and connectors are available for an additional charge. For on-line use, our fc75p 3/4 inch in-line fitting may be ordered to provide for mounting into 3/4 inch fnpt threaded tees. Do1200 dissolved oxygen sensor specifications * range: 0-20 mg/l * body material: epoxy and noryl * max temperature: 50 degrees c * saturation output: hdpe = 47mv +/- 9mv, ptfe = 33mv+/-9mv * pressure: 0-100 psig (7.5 bar) * calibration: single point in air * response time: after equilibration, hdpe 1 minute for 2mv, ptfe 2 minutes for 2mv