Key Specifications/Special Features: Aerospace quality, professional technology, a popular model Easy to take, dampproof, quakeproof and salt fog resistance Invasive, non invasive and manual ventilation in one machine Volume regulation, pressure limit, time switch, demonstrating the strategy of lung protection Inspiration halt, convenient for sucking phlegm and avoiding cross infection Driven mode: pneumatically driven and electrically controlled Three kinds of power supply: A/C, D/C and on vehicle power supply Application: adult & child Ventilation modes Volume control: A/C SIMV A/C + SIGH Manual Ventilation SPONT NIPPV Controlling part Tidal volume (VT): 50ml~1500ml Minute Volume: 0~20L/min I/E Ratio: 1:0.3, 1:0.5, 1:0.7, 1:1, 1:1.5, 1:2, 1:2.5, 1:3, 1:3.5, 1:4 Respiratory rate (f): 4~80bpm Limited pressure: 1kPa ~ 5kPa Trigger sensitivity: 2kPa ~ 2kPa Continuous current: 3 ~ 5LPM Manual inspiration halt: 20s Inhaled oxygen concentration: 48% ~ 100% consecutive adjustment Safety valve pressure limit: 5.1kPa ~ 6kPa Monitoring part LCD display Airway pressure waveform Inhaled tidal volume Minute Volume Total respiratory rate Peak airway pressure Trigger pressure AC/DC indication Could monitor all parameters and waveforms in manual mode Audible and visual alarm part Upper and lower airway pressure limit Power supply failure Low charge of battery Others Power supply: AC220V± 10%, 50Hz± 1Hz, 12V on vehicle power supply Built in battery: provide a more than 2 hour power supply when power off Gas pressure: 0.25~0.6Mpa. Cylinder gas supply can work continuously for 30min. Ventilator compliance: 40 x 10 2 ml/Pa Weight: 22kg Export Carton Dimensions: 60x 40 x54 cm
The Shangrila 510S is a universally used model. Not only for emergency ventilation, but also it is suitable for ideal transport ventilation. The circumstances include on-site emergency treatment, pre-hospital transport, interhospital transport, and even intra-hospital transport. Specification Ventilation Mode: Assist/Control (A/C) Manual Parameter MV: 3~20 L/min (used in 60%), 3~14L/min (used in 100%) Respiratory rate: 10~60bpm I:E ratio: 1:2 FiO2: 60%,100% Trigger sensitivity: Pressure, -3cmH2O Monitoring Pressure values: Paw Alarm: Paw high, O2 supply down Technical Data Gas supply: O2, 0.28~0.6MPa Maximum security pressure: 8kPa Compliance: 4mL/100Pa Noise: 65dB(A) Dimensions (H WD):276 110142mm Weight: 2.4kg Environment Requirement Temperature:-18C~50C (Operation)-20C~55C (Storage) Relative humidity: 5%~95%, non-condensing (Operation) 93% (Storage) Atmospheric pressure: 70~110kPa (Operation), 50~110kPa (Storage)
P30 Portable Non-invasive ventilation P30 is mainly applicable to patients with mild or moderate respiratory failure, no evidence of emergency intubation, relatively stable vital signs, and no contraindication to non-invasive ventilation. It is used for early intervention and assisted withdrawal of respiratory failure. Advantages Small SIze and easy to carry Color LCD display, easy to operate Display and monitor patient clinical usage data in real time Features Low-flow oxygen can be connected for air-oxygen mixing Has VAF target tidal volume function Can be equipped with blood oxygen module Can be equipped with an independent humidifier Configurable trolley Maximum JPAP to 30cmH20 Ventilation mode: CPAP, APAP, S, ST, T, APCV, AutoB 4 work modes: CPAP, S, T, S/T, APCV APCV mode:Assist pressure control ventilation Dynamically monitor the treatment effect Real-time alarm in case of failure Light weight:2.0kg (without trolley) Scope of application Assistant therape of respiratory disease, HD(Pulmonary heart disease), COPD(chronic obstructive pulmonary disease), Motor neurons. Specifications Difference: B-30P Screen: 3.5 Inch color TFT Work mode: CPAP, S/T, S, T, APCV Inspiration Pressure: 4-30cmH20 Inspiration Sensitivity: Auto, 1-6 level Expiration Pressure: 4-25cmH20 VAF function: Yes, Tidal Volume 50-2000ml
1: 2nosx 3 in 1 dredgers 2: All 2 vessel in Singapore flag 3: price: SGD2.5mill each 4: location singapore waters.
We have various icu and portable ventilator model . Example: VG 70 , S1100 , S3010ï¼? V6ï¼? 510Sï¼? YH-830ï¼? SH300 and ACM812A .
Plug & play home ip camera with free management software on pc and smartphones.
1. 3 bus bar multicrystalline silicon solar cell Power: 3.3Wp - 3.5Wp Quantity: 50k - 100k /month 2. 3 bus bar multicrystalline silicon solar cell Power: 3.7Wp - 3.9Wp Quantity: 50k - 100k /month 3. 3 bus bar monocrystalline silicon solar cell Power: > 4.0Wp Quantity: 50k /month 4. 2 bus bar multicrystalline silicon solar cell Power: 3.7Wp - 3.9Wp Quantity: 150k /month.
Type Multi crystalline silicon wafer ( B grade) Size(mm) 156.6 (+0.0 to -0.5). P/N type P Do pant Boron Resistivity(ohmcm) 0.5 û 5.0 Carbon Content 5.0x1017 atoms per cm3 Oxygen Content 3.0x1017 atoms per cm3 Life Time > 1.5 microsecond. T T V less than or equal 50 microm. Thickness 200 microm(+/- 30 microm) Production(Casting) method EMC Diffusion length greater than or equal to 50 micrometer Conner angle(degree) 90.0 +/- 0.3 Beveled edge width 0.5 - 2 mm Appearance Chip ( Width 0.8 mm, less than or equal 4 points.
230Wp and above high quality solar panels for sale.
2 volt ad 12 volt with many different current rate.
Solar panel frame with high quality and all kinds of different size.
Typically for large-scale photovoltaic off-grid power systems, the specially designed high power photovoltaic intelligent controllers, multi-channel input array of PV modules, convergence to one output. For the battery charge and discharge management, according to the battery pack voltage changes, it automatically controlling components and modules connect or disconnect to maximize the use of solar energy, and also avoids battery overcharge or over discharge problem. In addition, through the power controller multi-input, multi-chip components can be simply connected the controller to solve the traditional large-scale systems require multiple small controllers, complex parallel wiring, to avoid errors caused by lining issues. According to off-grid photovoltaic power system and the different battery design, solar controller are divided into 24V, 48V, 96V, 120V, 192V and 240V and other specifications to meet different users' needs or program designer
Grade one goose feather tournament shuttlecock. 12 shuttlecocks/tube, 50 tubes per carton.
For OEM users or laser integrators, we can provide you with a range of high performance components and sub-assemblies at more attractive prices. The OEM pulsed laser consists of a laser head (pump chamber, Nd:YAG rod, lamp, laser resonator, optional aperture and optional beam expander), a lamp driver (power supply) and an optional chiller. These lasers can be used for laser welding and cutting. 55KG vary for different model.
1. High Performance CW Arc Lamps (Kr lamps) 2. High Performance Pulse Flashlamps (Xe lamps) 3. IPL Lamps.
355nm, 532nm, 1064nm, 10.6um f-theta lens. Portable size.
STSL scanner lenses specially designed and optimized for use in CO2 laser 2-axis galvo-scanner systems with full beam diameters of up to 15.0mm. Mirror sets appropriate for use with beam diameters up to 15mm require an increase in mirror separation in comparison with smaller mirrors. These changed optical conditions are catered-for by the STSL series. These single-element lenses are designed to represent the best achievable compromise for on-axis and off-axis aberrations, field flatness and F-theta characteristics, obtainable using single-element spherical-surface designs of (standard) 48mm diameter and 3mm edge thickness. The lens material is ZnSe. 48mm lens diameter.
Gooch & Housego products. There are following Q-switches in stock and they can be immediately delivered: QS27-6.5C-B, QS27-5S-B, QS27-5C-B, QS27-4C-B, QS27-4S-B, QS27-4S-S, QS27-3C-S, QS27-3S-S and Stallion series Q-switches. Portable size.
A whole laser marking head (or called laser scanner) consists of two scan mirrors, two galvanometers (or called galvo-scanner motor) & drive cards, a XY mount, a scanning lens (f-theta lens), an interface card (or called D/A card), a set of marking software and a DC power supply. Two types of scanning optics for CO2 and Nd:YAG lasers are available.
IRVBeam visualizerÆs are suitable for use with lasers that operate in CW Q-sw, PS.