The Nucleic Acid Isolation Kit (Magnetic Beads Method) is designed for the automated purification of RNA and DNA from body fluids (such as swabs, plasma, serum) using automated nucleic acid extraction instruments. Magnetic- particle technology provides high-quality DNA/RNA that is suitable for direct use in downstream applications such as amplification or other enzymatic reactions. We provide different models to match different machines, also, we can provide OEM service for customers
Fast detection of current Covid-19 condition in 10 Minutes. Suitable for testing large number of of patients. Affordable testing expenses. Certified Quality Standards. Approved by Health Science Authority of Singapore.
GraceTree COVID-19 IgM/IgG Rapid differential detection kit for IgM and IgG against COVID-19 in human serum, plasma and whole blood Feature & Type : IgM/IgG 1) COVID-19 IgM/IgG : blood test 2) Dual-band results for simple interpretation 3) Multivariable analysis of immunoglobin IgG & IgM 4) Positive percent agreement (PPA) = 96.0% Negative percent agreement (NPA) = 98.99% 5) Room temperature storage ( 2~30C / 36~86F ) 6) Time to result : 2 min 7) Expiration date of this kit is 6 months after its manufacture date 8) MATERIALS PROVIDED - Test device individually foil-pouched with a desiccant - Assay solution in dropping bottle - Capillary tube for sample loading - Instructions for Use - Packing: 1 box of 25 Test units - Product Origin : South Korea - Certificate : FDA EUA Certificate will be proved near 15. September. 2020 - Shipping Terms : FOB - Payment Terms : T/T - MOQ : Under Discussion - Contract : Direct contract seller / Depending on volume, direct contract with a subsidiary of seller which is listed on stock market(in S.Korea) - LOI, POF needed for seller
Product Details: Usage/Application Hospital Tests Kit Filarial antigen Results 10 min The BinaxNOW Filariasis is an in vitro immunodiagnostic test used to detect Wuchereria bancrofti antigen in whole blood, serum, or plasma. The test employs an antibody specific for W. bancrofti. Accurate: Lymphatic filariasis does not always result in clinical symptoms so the most accurate way to diagnosis is using a blood test. Simple: The BinaxNOW Filariasis card test does not require laboratory facilities. Convenient: The test uses finger-prick blood taken at any time of the day without regard to nocturnicity of parasite. Traditionally testing was restricted to the hours of 10 pm and 2 am when the parasite appeared in the patientâ??s blood. Flexible: The test detects filarial antigen in whole blood, serum or plasma. Rapid: The test yields results in 10 minutes.
Coronavirus Diagnostics Kits. Covid 19 Test Equipment (IgG/IgM Antibody Test Kit). Manufacturerd : South Korea. Test time : Within 10 mins. COVID-19 antibodies detection in serum, plasma or whole blood.
This product is used for sample collection, transportation and storage, such as the samples collection of SARS-CoV-2 oropharyngeal swabs.
This product is the rapid testing of COVID-19, the result come out within 10 minutes.
The Kit provides a rapid and easy method for the isolation of viral RNA and DNA from plasma, serum, and cellfree body fluids using silica membrane technology. Description The Kit provides a rapid and easy method for the isolation of viral RNA and DNA from plasma, serum, and cellfree body fluids. It is based on silica membrane technology and provides special buffer system. A specially formulated buffer system allows nucleic acid to bind to the membrane. Samples are lysed under denaturing conditions and then transferred to the nucleic acid column where nucleic acid binds and cellular debris, hemoglobin, and other proteins are washed away. High-quality nucleic acid is eluted in nuclease-free water. Phenol extraction and ethanol precipitation are not required. nucleic acid purified can be directly used in downstream molecular biology experiments such as PCR and real time qPCR, and next generation sequencing. Keys *Â The kit can extract viral RNA and DNA simply and fast by adopting the silica membrane spin column. * Safe and non-toxic because there's no need for phenol/chloroform extraction. * High-quality viral RNA and DNA can be obtained within 45 minutes. * Complete removal of contaminants and PCR inhibitors for downstream experiments. Features Specification Starting Amount - 200 ul Starting Material - Plasma, serum, and other acellular body fluids Elution Volume - 30-150 Technology - Column membrane technology Processing Mode - Manual Throughput - 1-24 samples/run Storage - Room temperature (15-25) Applications - PCR and real time qPCR, and next generation sequencing. Especially for Virus infectious diseases analysis.
The Kit follows a magnetic bead-based approach for the rapid and reliable isolation of viral RNA/DNA from nasopharyngeal (NP) swab specimens that are dry or in viral transport media (VTM). Description The Kit follows a magnetic bead-based approach for the rapid and reliable isolation of viral RNA/DNA from nasopharyngeal (NP) swab specimens that are dry or in viral transport media (VTM). The extraction methodology is easily adaptable to various automated systems and can also be scaled up or down depending on the amount of starting sample amount used. The kit enables purification of high-quality nucleic acids that are free of proteins, nucleases, and other impurities. Nucleic acid isolated by the kit is stable with good integrity and purity, and can be directly used in downstream molecular biology experiments such as PCR and real time qPCR, and next generation sequencing. Keys *Â Magnetic bead-based purification *Â High-quality nucleic acid can be obtained range from 10 min to 40min (up to different protocol). * High throughput: Can be integrated with magnetic rod method automatic instrument or pipetting method automatic instrument to carry out high throughput extraction experiment. *Â Safe and nontoxic: No toxic organic reagents such as phenol/chloroform are needed. *Â Complete removal of contaminants and PCR inhibitors for downstream experiments. Features Specification Starting Amount - 200ul Starting Material - swab specimens or in viral transport media (VTM). Elution Volume - 80-150L Technology - Magnetic bead-based purification technology Processing Mode - Manual or Auto Throughput - 32/48/96/192 samples/run(up to different machine). Storage - Room temperature (15-25) Applications PCR and real time qPCR, and next generation sequencing.
This kit is used to qualitatively detect the novel coronaviruses (SARS-CoV-2) antigen in human nasal throat swabs, oral throat swabs, posterior oropharyngeal saliva, sputum and stool samples.
African swine fever virus (ASFV) real-time PCR test kit enables the safe detection of African swine fever virus DNA in serum, blood, tissue, lymph nodes, spleen, muscle from pigs and breeding environment samples within 40 minutes. The kit consists of fluorescence PCR mix , positive control , negative control and lysis solution for real-time PCR amplification of ASFV. Fluorescence PCR mix contains primers, probes, enzyme and buffer for detection of the ASFV P72 gene. In addition, the role of lysis solution is to simply process samples and release DNA.
* NEW* Covid-19 ANTIGEN RAPID TEST KIT *NEW * with CE Mark EU APPROVED | Collodial Gold Method | 15 Minutes Rapid Covid-19 Rapid Antigen Test Kit | Collodial Gold Method Accurate: 96.1% sensitivity, 96.67% specificity compared with PCR FAST: only 15 minutes required EASY-TO-USE: no special requirements Room temperature storage MOQ 2000 units (25pcs) per unit MAX 300.000 units PER DAY Payment terms 100% TT in Advance Lead time 7 days Global delivery Results
Jet A1, D6 , Lng , En590 10ppm&50ppm.
Gasoil 10ppm / en590 / bitumen.
Heavy crude oil, light crude oil, d2, gasoil, lpg, bitumen, sulphur, urea.Trade, consulting
D2, LNG, EN590, sugar, sea sand & river sand.
Gas Oil 500 ppm, 10ppm.
Oil and gas products.
STANDARD M nCoV Real-Time Detection kit is used for rapid identification and detection of novel coronavirus (2019-nCoV) nucleic acids in human nasopharyngeal swabs and throat swab samples. Coronavirus RNA was first transcribed into cDNA by reverse transcriptase, and then cDNA was used as a template for PCR amplification. The separation of the fluorophore and quencher makes the fluorescence signal detected by the instrument: FAM channel qualitative detection of the new coronavirus (COVID-19) ORF1ab gene, and JOE channel qualitative detection of coronavirus) E gene, and CY5 channel detection internal reference. The kit uses dUTP and UNG enzymes to prevent contamination of amplification products.
Result in 10 to 15 minutes, no equipment is required 25 pcs per box 50 boxes per carton about 600 cartons per FCL Shelf life 24 months