Specific property for usage of 110kv~220kv xlpe high-voltage cable 1. Cable's conductor highest working temperature is allowed up to 90⺠c, and overload when meet an emergency is 130⺠c, when short circuit (in â?¤ 5 seconds) the highest temperature is 250⺠c 2. When installing or laying cable, the ambient temperature should be less than -20⺠c, and have to give a preheat to cable. 3. The minimum bending diameter(in follow the table): Note: in form, d0 is a real test value to cable's outer diameter. 4. Allowed biggest axial traction force to outer diameter when laying cable (not consider the radial lateral-pressure at bent set ion) t=kã? core no. Ã? section (kg), in formula, the coefficient k value should be: the copper core get 7, the aluminum core get 4. 5. Allowed biggest lateral-press p, when cable is being bent The single core cable is required pâ?¤ 500kg/m. P=t/r (t is indicated axial traction force; r is indicated radius of bent-wheel), knowing from above formula, as the traction force is made up by length and weight of cable. So it lets p to applying requirement as above. Then the diameter of bent-wheel should be widened. 6. Cable laying is not being restricted by drop.
Our power cords are engineered for reliability and versatility available in both standard and customized configurations to meet your specific power needs Choose from 2pin and 3pin options to ensure compatibility with a wide range of devices and applications Key Features Versatile Pin Options Available in 2pin and 3pin configurations to accommodate various devices and power requirements Standard Options Premade power cords in commonly used lengths eg 1m 2m 3m for quick and easy deployment Customized Solutions Tailor your power cord to your exact specifications including length pin configuration and cable color HighQuality Materials Constructed from durable flameretardant materials to ensure safety and longevity Safety Certifications Compliant with international safety standards providing peace of mind for users Flexible Design The flexible cable design allows for easy routing in tight spaces while maintaining durability Wide Application Range Suitable for home appliances industrial equipment computers and more Key Advantages Enhanced Compatibility Ensures reliable connections for a variety of devices reducing the risk of power issues Customization Options Meet unique requirements by choosing the length pin type and other specifications tailored to your needs Durable and Safe Built to withstand everyday wear and tear with safety features that protect against overheating and electrical faults Convenient Lengths Options for different lengths help you manage space efficiently whether at home or in the workplace CostEffective Solution Highquality materials and customization options provide excellent value and longevity minimizing the need for replacements Whether you need a standard power cord for everyday use or a customized solution for a specific application weve got you covered Contact us today to find the perfect power cord for your needs
XLPE Insulated Power cables We are supplying wide range of XLPE insulated power cables. It is important that while placing enquiries or orders, as much information as possible shall be given to us, so that the enquiries and orders are dealt quickly and efficiently. 1) Voltage Grade : 1.9 / 3.3 kV (E), 3.3 / 3.3 kV (UE), 3.8 / 6.6 kV (E) , 6.6 / 6.6 kV (UE), 6.35 / 11 kV (E), 11 / 11 kV (UE), 12.7 / 22 kV (E) & 33 kV (E), 33 kV (UE) , 45 kV & 66kV 2) Relevant Indian or International standard: IS 7098 (Part-2) 1985 or IEC-60502 (Part-2), BS-6622 & BS: 7835. 3) Number of cores:- Single & Three. 4) Conductor Size - 35 Sq.mm to 1000 Sq.mm in Single Core Cables & 35 Sq.mm to 400 Sq.mm in 3 Core cables. 5) Conductor Material: Copper / Aluminum 6) Type of Insulation: XLPE 7) Type of Inner Sheathing: PVC Wrapped / PVC Extruded. 8) Type of Armour: Unarmoured / Strip Armoured / Round Wire Armoured. 9) Type of Outer Sheath: PVC / Flame Retardant / Flame Retardant Low Smoke / Zero Halogen (LSOH). 10) Length of cable required per drum. Note: Detailed Leaflet for 66kV & above can be available on specific request
XLPE Insulated Power cables We are supplying wide range of XLPE insulated power cables. It is important that while placing enquiries or orders, as much information as possible shall be given to us, so that the enquiries and orders are dealt quickly and efficiently. 1) Voltage Grade : 1.9 / 3.3 kV (E), 3.3 / 3.3 kV (UE), 3.8 / 6.6 kV (E) , 6.6 / 6.6 kV (UE), 6.35 / 11 kV (E), 11 / 11 kV (UE), 12.7 / 22 kV (E) & 33 kV (E), 33 kV (UE) , 45 kV & 66kV 2) Relevant Indian or International standard: IS 7098 (Part-2) 1985 or IEC-60502 (Part-2), BS-6622 & BS: 7835. 3) Number of cores:- Single & Three. 4) Conductor Size - 35 Sq.mm to 1000 Sq.mm in Single Core Cables & 35 Sq.mm to 400 Sq.mm in 3 Core cables. 5) Conductor Material: Copper / Aluminum 6) Type of Insulation: XLPE 7) Type of Inner Sheathing: PVC Wrapped / PVC Extruded. 8) Type of Armour: Unarmoured / Strip Armoured / Round Wire Armoured. 9) Type of Outer Sheath: PVC / Flame Retardant / Flame Retardant Low Smoke / Zero Halogen (LSOH). 10) Length of cable required per drum. Note: Detailed Leaflet for 66kV & above can be available on specific request
â?¢ XLPE Insulated Power cables We are supplying wide range of XLPE insulated power cables. It is important that while placing enquiries or orders, as much information as possible shall be given to us, so that the enquiries and orders are dealt quickly and efficiently. 1) Voltage Grade : 1.9 / 3.3 kV (E), 3.3 / 3.3 kV (UE), 3.8 / 6.6 kV (E) , 6.6 / 6.6 kV (UE), 6.35 / 11 kV (E), 11 / 11 kV (UE), 12.7 / 22 kV (E) & 33 kV (E), 33 kV (UE) , 45 kV & 66kV 2) Relevant Indian or International standard: IS 7098 (Part-2) 1985 or IEC-60502 (Part-2), BS-6622 & BS: 7835. 3) Number of cores:- Single & Three. 4) Conductor Size - 35 Sq.mm to 1000 Sq.mm in Single Core Cables & 35 Sq.mm to 400 Sq.mm in 3 Core cables. 5) Conductor Material: Copper / Aluminum 6) Type of Insulation: XLPE 7) Type of Inner Sheathing: PVC Wrapped / PVC Extruded. 8) Type of Armour: Unarmoured / Strip Armoured / Round Wire Armoured. 9) Type of Outer Sheath: PVC / Flame Retardant / Flame Retardant Low Smoke / Zero Halogen (LSOH). 10) Length of cable required per drum. Note: Detailed Leaflet for 66kV & above can be available on specific request
XLPE insulated power cable is used to transmit power on the power tansmission and distribution of AC,rated voltage 35kv or lower.Incompatison with PVC insulation cable,It boasts not only excellent electric character,mechanical chatacter,heat and agingresistant character,environmental stress-resistant chatacter and chemical corrosionresistant chatacter,but simplw structure,light weight,no restiction by laying drop,and hight temperature allowance for long-term working as well. Executive standard 1)GB/T12706.1-2002(Equivalent IEC 60502) Rated voltage 1kv (Um=1.2kv)and power cable 2)GB/T12706.2-2002(Eqquivalent IEC60502-2)Rated voltage6 kvUm=7.2kv and Um=36kv power cable 3)G/BT12706.3(VOLTAGE Grade Overtep IEC 60502-2) Rated Voltage3.5V Um=40.5kv and power cable. Working consitions: 1) This maximum working temperatuie of thr conductor temperature is +90. During having a short (lasting less than 5 seconds )the maximum temperature of the cable conductor shall not be above +250 Environment temperture should be no lower than+0 for laying the cable. 2) Bending radius allowance of the cable: Single core cable:No steel tape cable 20D,steel tape cable 15D Cores cabel: No steel tape cable 15D steel tape cable 12D Notes: D ptactical esternal diameter of cable. Wooden drums
XLPE Insulated Power Cable Brief introduction to XLPE insulated Power Cable Since the 1960â??s, China has made rapid progress in its XLPE cable, replacing the oil paper insulated power cable, because of its outstanding electricity property , good overload , high voltage , large transmission capacity , light weight and laying without drop limit, vertical laying, convenient installation and operation maintenance and other strong points , XLPE cable can not only be widely used in 35 KV and below medium and Low voltage Cable scope, but also largely used in 66, 110 and 220 KV high voltage transmission lines. And , in some developed industrial countries 500 KV super-high voltage XLPE cables have been opened up.. Product Standard Huiyou Cablefocus on Various Power Cables, Our High Voltage XLPE Cables are very popular, and Our factory cab also design and produce some XLPE Insulated Power Cable for special requirements according to clientsâ?? demand. if you are interested in our products, please contact us as soon as possible. Property for Use a.Max rated temperature of cable conductor is 90 b.For short circuit ( Maximum sustained time not exceeding 5s), maximum temperature of cable conductor not exceeding 250 Cable rated voltage selection : Cable rated voltage should be suitable to the system voltage and operation conditions of used cable, expressed by U0/U(Um), all are effective value, unit is KV .
http://www.zmscable.com/powercables/828.html
http://www.zmscable.com/powercables/818.html
http://www.zmscable.com/powercables/818.html
http://www.zmscable.com/powercables/820.html -
Http://www.Zmscable.Com/powercables/823.Html -
Http://www.Zmscable.Com/powercables/828.Html -
Http://www.Zmscable.Com/powercables/828.Html -
High Voltage Copper Conductor XLPE Insulated Power Cable
High Voltage Copper Conductor XLPE Insulated Power Cable www.vericable.com
XLPE Insulated Power Cable Application: XLPE Insulation Power Cables used to transmit and distribute power on the power line of rated voltage 0.6/1kv, 3.6/6kv, 6/6kv, 6/10kv, 8.7/10kv, 8.7/15kv,12/20kv and 21/35kv. Work Conditions: Long-term Max. Temperature is no more than 90,temperature of cable conductor is no more than 250 during sort circuit, the longest lasting time shall be not more than 5 seconds. Environment temperature for installation is no less than 0
STANDARD:IEC 60840 AS/NZS1429.2 VDE 0276-632 VOLTAGE:up to 110kV CAPACITY:2000km/month good electrical, mechanical and thermal characteristics excellent moisture, chemical and weather resistant low dielectric factor than PVC insulation and better dielectric constant constant performance at a long temperature range long service span LV:IEC60502-1 ,VDE 0276-603, ICEA S-95-658 ,AS/NZS 5000.1 MV:IEC60502-2 ,VDE 0276-620 ,AS/NZS1429.1 ,ICEA S93-639 ,ICEA S94-649 HV:IEC 60840 ,AS/NZS1429.2 ,VDE 0276-632