Specific property for usage of 110kv~220kv xlpe high-voltage cable
1. Cable's conductor highest working temperature is allowed up to 90⺠c, and overload when meet an emergency is 130⺠c, when short circuit (in � 5 seconds) the highest temperature is 250⺠c
2. When installing or laying cable, the ambient temperature should be less than -20⺠c, and have to give a preheat to cable.
3. The minimum bending diameter(in follow the table):
Note: in form, d0 is a real test value to cable's outer diameter.
4. Allowed biggest axial traction force to outer diameter when laying cable (not consider the radial lateral-pressure at bent set ion) t=kã? core no. Ã? section (kg), in formula, the coefficient k value should be: the copper core get 7, the aluminum core get 4.
5. Allowed biggest lateral-press p, when cable is being bent
The single core cable is required pâ?¤ 500kg/m.
P=t/r (t is indicated axial traction force; r is indicated radius of bent-wheel), knowing from above formula, as the traction force is made up by length and weight of cable. So it lets p to applying requirement as above. Then the diameter of bent-wheel should be widened.
6. Cable laying is not being restricted by drop.
Application :- The XLPE (Cross Link Poly Ethylene) Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with XLPE compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The outer sheaths can be PVC, HR PVC, FRLS or FR depending upon the application and requirement. Technical Advantage of XLPE Insulation :- Higher current rating, higher short circuit rating (approx 1.2 times that of PVC), thermosetting in nature, higher insulation resistance (1000 times more than PVC cables), higher moisture resistance, better resistance to surge currents, low dielectric losses, better resistance to chemicals and corrosion, longer service life. Comparatively higher cable operating temperature 90�°C and short circuit temperature 250�°C. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +90�°C Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:7098 (Part-1) Packing : 500 / 1000 meters on drums
Application :- The Power Cables are used under ground as well as over head transmission of power in power plants, industries, projects and all other electrical installations. Features :- Manufactured from bright annealed 99.97% pure bare copper & aluminum conductors. These cables are insulated with PVC compound. Taped/Extruded inner sheath. Round steel wire / flat galvanised steel grip armoured. The inner & outer sheaths can be PVC, HR PVC, FRLS, HR-FRLS or FR depending upon the application and requirement. Technical Data :- Working Voltage : Up to 1100 V Temperature Range : -15�°C to +70�°C or +85�°C in HR PVC Power Cable Sizes : 1.50 Sq. mm to 400.00 Sq. mm in 2, 3, 3 & 4 core. Copper Control Cable Sizes : 1.50 Sq. mm, 2.50 Sq. mm up to 24 cores. Color Codes : 2 Core Cables - Red, Black 3 Core Cables - Red, Yellow & Blue 3 Core Cables - Red, Yellow, Blue & Black (for Neutral) 4 Core Cables - Red, Yellow, Blue & Black 5 Core Cables - Red, Yellow, Blue, Black & Grey 6 Core Cables & above - Adjacent cores are blue for reference and yellow for direction in each lay Black outer sheath Specification : IS:1554 (Part-1) Packing : 500 / 1000 meters on drums
Supplier: Marble, granite, stones, slates, tiles, power cord, wires, cables , cable assemblies, tyre scrap, used tyres, steel tire wire scrap, firewoods, pistachios, hazelnuts, textiles
Buyer: Pellets, briquettes, firewood, textiles
XLPE Insulated Power cables We are supplying wide range of XLPE insulated power cables. It is important that while placing enquiries or orders, as much information as possible shall be given to us, so that the enquiries and orders are dealt quickly and efficiently. 1) Voltage Grade : 1.9 / 3.3 kV (E), 3.3 / 3.3 kV (UE), 3.8 / 6.6 kV (E) , 6.6 / 6.6 kV (UE), 6.35 / 11 kV (E), 11 / 11 kV (UE), 12.7 / 22 kV (E) & 33 kV (E), 33 kV (UE) , 45 kV & 66kV 2) Relevant Indian or International standard: IS 7098 (Part-2) 1985 or IEC-60502 (Part-2), BS-6622 & BS: 7835. 3) Number of cores:- Single & Three. 4) Conductor Size - 35 Sq.mm to 1000 Sq.mm in Single Core Cables & 35 Sq.mm to 400 Sq.mm in 3 Core cables. 5) Conductor Material: Copper / Aluminum 6) Type of Insulation: XLPE 7) Type of Inner Sheathing: PVC Wrapped / PVC Extruded. 8) Type of Armour: Unarmoured / Strip Armoured / Round Wire Armoured. 9) Type of Outer Sheath: PVC / Flame Retardant / Flame Retardant Low Smoke / Zero Halogen (LSOH). 10) Length of cable required per drum. Note: Detailed Leaflet for 66kV & above can be available on specific request
XLPE Insulated Power cables We are supplying wide range of XLPE insulated power cables. It is important that while placing enquiries or orders, as much information as possible shall be given to us, so that the enquiries and orders are dealt quickly and efficiently. 1) Voltage Grade : 1.9 / 3.3 kV (E), 3.3 / 3.3 kV (UE), 3.8 / 6.6 kV (E) , 6.6 / 6.6 kV (UE), 6.35 / 11 kV (E), 11 / 11 kV (UE), 12.7 / 22 kV (E) & 33 kV (E), 33 kV (UE) , 45 kV & 66kV 2) Relevant Indian or International standard: IS 7098 (Part-2) 1985 or IEC-60502 (Part-2), BS-6622 & BS: 7835. 3) Number of cores:- Single & Three. 4) Conductor Size - 35 Sq.mm to 1000 Sq.mm in Single Core Cables & 35 Sq.mm to 400 Sq.mm in 3 Core cables. 5) Conductor Material: Copper / Aluminum 6) Type of Insulation: XLPE 7) Type of Inner Sheathing: PVC Wrapped / PVC Extruded. 8) Type of Armour: Unarmoured / Strip Armoured / Round Wire Armoured. 9) Type of Outer Sheath: PVC / Flame Retardant / Flame Retardant Low Smoke / Zero Halogen (LSOH). 10) Length of cable required per drum. Note: Detailed Leaflet for 66kV & above can be available on specific request
â?¢ XLPE Insulated Power cables We are supplying wide range of XLPE insulated power cables. It is important that while placing enquiries or orders, as much information as possible shall be given to us, so that the enquiries and orders are dealt quickly and efficiently. 1) Voltage Grade : 1.9 / 3.3 kV (E), 3.3 / 3.3 kV (UE), 3.8 / 6.6 kV (E) , 6.6 / 6.6 kV (UE), 6.35 / 11 kV (E), 11 / 11 kV (UE), 12.7 / 22 kV (E) & 33 kV (E), 33 kV (UE) , 45 kV & 66kV 2) Relevant Indian or International standard: IS 7098 (Part-2) 1985 or IEC-60502 (Part-2), BS-6622 & BS: 7835. 3) Number of cores:- Single & Three. 4) Conductor Size - 35 Sq.mm to 1000 Sq.mm in Single Core Cables & 35 Sq.mm to 400 Sq.mm in 3 Core cables. 5) Conductor Material: Copper / Aluminum 6) Type of Insulation: XLPE 7) Type of Inner Sheathing: PVC Wrapped / PVC Extruded. 8) Type of Armour: Unarmoured / Strip Armoured / Round Wire Armoured. 9) Type of Outer Sheath: PVC / Flame Retardant / Flame Retardant Low Smoke / Zero Halogen (LSOH). 10) Length of cable required per drum. Note: Detailed Leaflet for 66kV & above can be available on specific request
XLPE insulated power cable is used to transmit power on the power tansmission and distribution of AC,rated voltage 35kv or lower.Incompatison with PVC insulation cable,It boasts not only excellent electric character,mechanical chatacter,heat and agingresistant character,environmental stress-resistant chatacter and chemical corrosionresistant chatacter,but simplw structure,light weight,no restiction by laying drop,and hight temperature allowance for long-term working as well. Executive standard 1)GB/T12706.1-2002(Equivalent IEC 60502) Rated voltage 1kv (Um=1.2kv)and power cable 2)GB/T12706.2-2002(Eqquivalent IEC60502-2)Rated voltage6 kvUm=7.2kv and Um=36kv power cable 3)G/BT12706.3(VOLTAGE Grade Overtep IEC 60502-2) Rated Voltage3.5V Um=40.5kv and power cable. Working consitions: 1) This maximum working temperatuie of thr conductor temperature is +90. During having a short (lasting less than 5 seconds )the maximum temperature of the cable conductor shall not be above +250 Environment temperture should be no lower than+0 for laying the cable. 2) Bending radius allowance of the cable: Single core cable:No steel tape cable 20D,steel tape cable 15D Cores cabel: No steel tape cable 15D steel tape cable 12D Notes: D ptactical esternal diameter of cable. Wooden drums
XLPE Insulated Power Cable Brief introduction to XLPE insulated Power Cable Since the 1960â??s, China has made rapid progress in its XLPE cable, replacing the oil paper insulated power cable, because of its outstanding electricity property , good overload , high voltage , large transmission capacity , light weight and laying without drop limit, vertical laying, convenient installation and operation maintenance and other strong points , XLPE cable can not only be widely used in 35 KV and below medium and Low voltage Cable scope, but also largely used in 66, 110 and 220 KV high voltage transmission lines. And , in some developed industrial countries 500 KV super-high voltage XLPE cables have been opened up.. Product Standard Huiyou Cablefocus on Various Power Cables, Our High Voltage XLPE Cables are very popular, and Our factory cab also design and produce some XLPE Insulated Power Cable for special requirements according to clientsâ?? demand. if you are interested in our products, please contact us as soon as possible. Property for Use a.Max rated temperature of cable conductor is 90 b.For short circuit ( Maximum sustained time not exceeding 5s), maximum temperature of cable conductor not exceeding 250 Cable rated voltage selection : Cable rated voltage should be suitable to the system voltage and operation conditions of used cable, expressed by U0/U(Um), all are effective value, unit is KV .
http://www.zmscable.com/powercables/828.html