CE&ISO certified professional manufacturer of medical supplies lab consumables vacutainer since2009-Hebei Chaoran Medical Instruments Vacuum blood collection tubes are applicable to the clinical blood test and the blood cells analysis The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to analytical testing *Red: Non-additive - Serum *Red: Clot Activator-Serum *Yellow: Gel & Clot Activator -Serum *Purple: ETDA K2 / ETDA K3 - Whole blood *Black: 3.8% Sodium Citrate (1:4)- Whole blood *Blue: 3.2% Sodium Citrate (1:9)- Whole blood or Plasma *Green: Lithium Heparin / Sodium Heparin-Plasma *Grey: Glucose - Plasma Material:PET plastic or Glass Tube size :13*75mm,13*100mm Volume:1ml,2ml,3ml,4ml,5ml,6ml,7ml Etc Shelf Life:2years Disinfecting Type:gamma ray Sterilized:yes Band:Chaoran Sample:Availible OEM:Available Certificate:CE/ISO
Vacuum blood collection tubes are applicable to the clinical blood test and suitable for the blood cells analysis The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to analytical testing *Red: Non-additive - Serum *Red: Clot Activator-Serum *Yellow: Gel & Clot Activator -Serum *Purple: ETDA K2 / ETDA K3 - Whole blood *Black: 3.8% Sodium Citrate (1:4)- Whole blood *Blue: 3.2% Sodium Citrate (1:9)- Whole blood or Plasma *Green: Lithium Heparin / Sodium Heparin-Plasma *Grey: Glucose Plasma
Whole Blood Collection Tube Golden Vac whole blood collection tube promises to provide non-polluting and non-differential original blood specimen for medical test, does not require separation of plasma or cells. It includes 2 kinds of tubes: EDTA Tube with Purple cap, ESR Tube with black cap. EDTA Tube is widely used for clinical haematology test, especially for routine blood examination. Our automatic sampling instrument finely and accurately spray additives onto the interior tube wall, to ensure the mixing speed and the anticoagulation effect. EDTA Tube is very convenient to use for it can be directly put on the analyzer to detect without openning the cap. Item GD020EK3 , Specification Purple cap, EDTA K3, 13*75mm, 2ml, Item GD030EK3 , Specification Purple cap, EDTA K3, 13*75mm, 3ml, Item GD040EK3 , Specification Purple cap, EDTA K3, 13*75mm, 4ml, Item GD050EK3 , Specification Purple cap, EDTA K3, 13*75mm, 5ml, Item GD060EK3 , Specification Purple cap, EDTA K3, 13*100mm, 6ml, Item GD070EK3 , Specification Purple cap, EDTA K3, 13*100mm, 7ml, Item GD080EK3 , Specification Purple cap, EDTA K3, 16*100mm, 8ml, Item GD090EK3 , Specification Purple cap, EDTA K3, 16*100mm, 9ml, Item GD0100EK3 , Specification Purple cap, EDTA K3, 16*100mm, 10ml, Item GD080EK3R , Specification Rubber stopper, EDTA K3, 16*100mm, 8ml, Item GD090EK3R , Specification Rubber stopper, EDTA K3, 16*100mm, 9ml, Item GD0100EK3R , Specification Rubber stopper, EDTA K3, 16*100mm, 10ml, Item GD020EK2 , Specification Purple cap, EDTA K2, 13*75mm, 2ml, Item GD030EK2 , Specification Purple cap, EDTA K2, 13*75mm, 3ml, Item GD040EK2 , Specification Purple cap, EDTA K2, 13*75mm, 4ml, Item GD050EK2 , Specification Purple cap, EDTA K2, 13*75mm, 5ml, Item GD060EK2 , Specification Purple cap, EDTA K2, 13*100mm, 6ml, Item GD070EK2 , Specification Purple cap, EDTA K2, 13*100mm, 7ml, Item GD080EK2 , Specification Purple cap, EDTA K2, 16*100mm, 8ml, Item GD090EK2 , Specification Purple cap, EDTA K2, 16*100mm, 9ml, Item GD0100EK2 , Specification Purple cap, EDTA K2, 16*100mm, 10ml, Item GD080EK2R , Specification Rubber stopper, EDTA K2, 16*100mm, 8ml, Item GD090EK2R , Specification Rubber stopper, EDTA K2, 16*100mm, 9ml, Item GD0100EK2R , Specification Rubber stopper, EDTA K2, 16*100mm, 10ml, Item GD035EK3G , Specification Purple cap, EDTA K3 + Separate Gel , 13*75mm, 3.5ml, Item GD060EK3G , Specification Purple cap, EDTA K3 + Separate Gel , 13*100mm, 6ml, Item GD085EK3RG , Specification Rubber stopper, EDTA K3 + Separate Gel , 16*100mm, 8.5ml, Item GD085EK3G , Specification Purple cap, EDTA K3 + Separate Gel , 16*100mm, 8.5ml,
Non Vacuum Blood Tube Item GDN050EK3, Specification: 5ml EDTA K3 Non-vacuum blood collection tube, Green cap, Item GDN050EK2, Specification: 5ml EDTA K2 Non-vacuum blood collection tube, Green cap, Item GDN050A, Specification: 5ml Plain Non-vacuum blood collection tube, Red cap, Item GDN050CA, Specification: 5ml Clot Activator Non-vacuum blood collection tube, Red cap, Item GDN050SP, Specification: 5ml Fluoride Oxalate Non-vacuum blood collection tube, Yellow cap, Item GDN050LH, Specification: 5ml Lithium Heparin Non-vacuum blood collection tube, Dark Blue cap
Micro Collection Tube Micro Collection Tube is mainly used for peripheral blood collection. It is specially suitable for small children and geriatric patient. The inner surface has an excellent hemorepellency where it is necessary for a good preparation of high quality blood sample. Item GD005A , Specification: Micro Collection tube, Plain, 0.5ml , Item GD005CA , Specification: Micro Collection tube, Clot Activator 0.5ml , Item GD005EK3 , Specification: Micro Collection tube, EDTA K3, 0.5ml , Item GD005EK2 , Specification: Micro Collection tube, EDTA K2, 0.5ml , Item GD005LH , Specification: Micro Collection tube, Heparin Lithium, 0.5ml , Item GD005SH , Specification: Micro Collection tube, Heparin Sodium, 0.5ml , Item GD005SFH , Specification: Micro Collection tube, Heparin Sodium + Sodium Fluoride, 0.5ml , Item GD005SGC , Specification: Micro Collection tube, Gel + Clot Activator, 0.5ml , Item GDNM005A , Specification: Micro tube (High Type ) 0.5ml Plain 0.5ml, Item GDNM005CA , Specification: Micro tube (High Type ) 0.5ml Clot activator 0.5ml, Item GDNM005EK3 , Specification: Micro tube (High Type ) 0.5ml EDTAK3 0.5ml, Item GDNM005EK2 , Specification: Micro tube (High Type ) 0.5ml EDTAK2 0.5ml, Item GDNM005LH , Specification: Micro tube (High Type ) 0.5ml Gel 0.5ml, Item GDNM005SGC , Specification: Micro tube (High Type ) 0.5ml Gel 0.5ml, Item GDNM005SFH , Specification: Micro tube (High Type ) Glucose ( Heparin sodium,/ Sodium Fluoride) 0.5ml
K2 EDTA Tubes Specifications: Tube Size: 13-100 5.2mGs Membran Filtered EDTA K2 Sprayed Description EDTA stands for Ethylenedia minetetraacetic acid. EDTA functions by binding calcium in the blood and keeping the blood from clotting. It is used mostly i n Hematology studies: CBC, WBC Count, Hemoglobin, Hematocrit, Platelet Count, Reticulocyte count, and differential.
Capillary Blood Collection Tube Item GDC005A , Specification: Capillary Blood Collection Tube, Plain, 0.5ml Item GDC005CA , Specification: Capillary Blood Collection Tube, Clot Activator, 0.5ml Item GDC005EK3 , Specification: Capillary Blood Collection Tube, EDTA K3, 0.5ml Item GDC005EK2 , Specification: Capillary Blood Collection Tube, EDTA K2, 0.5ml Item GDC005LH , Specification: Capillary Blood Collection Tube, Heparin Lithium, 0.5ml Item GDC005SH , Specification: Capillary Blood Collection Tube, Heparin Sodium, 0.5ml Item GDC005SFH , Specification: Capillary Blood Collection Tube, Heparin Sodium + Sodium Fluoride, 0.5ml Item GDC005SGC , Specification: Capillary Blood Collection Tube, Gel + Clot Activator, 0.5ml
The tubes are designed for blood The tubes are designed for blood LYBCON Vacutainer sedimentation without the use of sedimentation pipettes. The blood is taken directly into the tubes and LYBCON Vacutainer turned end-over-end 8-10 times. Immediately before the tubes are placed in the stand for measurement, LYBCON Vacutainer the tubes must be mixed again. After one or two hours the results are read. The stand holds a LYBCON Vacutainer maximum of 10 tubes and has a height Lybcon adjustable zero mark. The measurement results achieved correspond to the Westergren method. MIXING RECOMMENDATION ESR (Erythrocyte Sedimentation Rate) tubes should be gently inverted 180 and back 8-10 times. SPECIFICATION Specimen: Whole Additive: Sodium citrate 3.8% (4NC) Cap color: Black Tube Size: 13x75mm Draw Volume: 1.6mL, 1.8mL Max. draw volume Tolerance: ±10% sedimentation without the use of sedimentation pipettes. The blood is taken directly into the tubes and LYBCON Vacutainer turned end-over-end 8-10 times. Immediately before the tubes are placed in the stand for measurement, LYBCON Vacutainer the tubes must be mixed again. After one or two hours the results are read. The stand holds a LYBCON Vacutainer maximum of 10 tubes and has a height LYBCON Vacutainer adjustable zero mark. The measurement results achieved correspond to the Westergren method. MIXING RECOMMENDATION ESR (Erythrocyte Sedimentation Rate) tubes should be gently inverted 180 and back 8-10 times. SPECIFICATION Specimen: Whole Additive: Sodium citrate 3.8% (4NC) Cap color: Black Tube Size: 13x75mm Draw Volume: 1.6mL, 1.8mL Max. draw volume Tolerance: ±10%
CE&ISO certified professional manufacturer of medical supplies lab consumables vacutainer since2009-Hebei Chaoran Medical Instruments Vacuum blood collection tubes are applicable to the clinical blood test and the blood cells analysis The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to analytical testing *Red: Non-additive - Serum *Red: Clot Activator-Serum *Yellow: Gel & Clot Activator -Serum *Purple: ETDA K2 / ETDA K3 - Whole blood *Black: 3.8% Sodium Citrate (1:4)- Whole blood *Blue: 3.2% Sodium Citrate (1:9)- Whole blood or Plasma *Green: Lithium Heparin / Sodium Heparin-Plasma *Grey: Glucose - Plasma Material:PET plastic or Glass Tube size :13*75mm 13*100mm Volume:1ml,2ml,3ml,4ml,5ml,6ml,7ml Etc Shelf Life:2years Disinfecting Type:gamma ray Sterilized:yes Band:Chaoran Sample:Availible OEM:Available Certificate:CE/ISO
CE&ISO certified professional manufacturer of medical supplies lab consumables vacutainer since2009-Hebei Vacuum blood collection tubes are applicable to the clinical blood test and the blood cells analysis The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to analytical testing *Red: Non-additive - Serum *Red: Clot Activator-Serum *Yellow: Gel & Clot Activator -Serum *Purple: ETDA K2 / ETDA K3 - Whole blood *Black: 3.8% Sodium Citrate (1:4)- Whole blood *Blue: 3.2% Sodium Citrate (1:9)- Whole blood or Plasma *Green: Lithium Heparin / Sodium Heparin-Plasma *Grey: Glucose - Plasma
Heat shrink tubing kosoo k2 Features/Benefits Shrinkage ratio: 2:1 Flexible, high flame retardance Excellent physical, chemical and electrical properties, for highly reliable, general purpose tubing Good abrasion and solvent resistance Complied with EN71 Part 3, EN1122, EPA3050B, EPA3052 European environmental standards Wide range of sizes and colors PACKED IN ROLL
LYBCON Vacutainer GEL-SST Advance tubes During the centrifugation of the LYBCON Vacutainer GEL-SST Advance tubes, an inert LYBCON Vacutainer gel separates the serum and the blood clot preventing the contamination of the serum from the separated cellular components. For example, the serum for certain analytes such as potassium, phosphorus and glucose must be separated from the cells within a few hours - otherwise the results will be significantly distorted. Using LYBCON GEL-SST Advance tubes routine analyses in clinical chemistry such as potassium and glucose are still stable after a week of storage at 2-8 C. Clinical evaluations of special chemistry demonstrate a high degree of analyte stability with the acrylic gel in the LYBCON GEL-SST Advance, with detection of >90% of the therapeutic drugs and other special analytes(proteins/peptides, steroids and vitamins) tested. As a result of the type of gel used in the GEL-SST Advance tubes, LYBCON Vacutainer short centrifugation times of 5 minutes at 3000g can be achieved. The stability of the gel barrier is a distinct advantage during transport and storage. The main advantages of gel tubes versus non-gel tubes are: Stable barrier between serum and clotted blood, therefore better analyse stability. Better sample quality. Optimisation of the work flow: Short centrifugation time, sample processing and archiving in the primary tube. No possibility of misidentification due to the use of secondary tubes. CLOTTING TIMES The minimum recommended coagulation time for GEL-SST Advance tubes for patients who have not LYBCON Vacutainer received anticoagulation treatment is 30 minutes. CENTRIFUGING CONDITIONS 1600-2000g for 10 minutes MIXING RECOMMENDATION Serum Separation Tubes should be gently inverted 180 and back 6-8 times. EFFECTS OF TEMPERATURE LYBCON Vacutainer GEL-SST Advance should be stored at 4-25C and protected from direct sunlight during storage. Cooling of the tube by or during centrifuging can affect the movement capability of the gel. The optimum separation of serum and coagulated blood is achieved at a temperature of 20-25C. Serum Separation Tubes should be gently inverted 180 and back 6-8 times. CLOT ACTIVATOR LYBCON Vacutainer GEL-SST Advance tubes contain silica particles. SPECIFICATION Specimen: Serum Additive: Gel & Clot Activator Cap color: Dark yellow Tube Size: 13x75mm Draw Volume: 3.5mL Max. draw volume Tolerance: ±10%
CE&ISO certified professional manufacturer of medical supplies lab consumables vacutainer since2009-Hebei Chaoran Medical Instruments Vacuum blood collection tubes are applicable to the clinical blood test and the blood cells analysis The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to analytical testing *Red: Non-additive - Serum *Red: Clot Activator-Serum *Yellow: Gel & Clot Activator -Serum *Purple: ETDA K2 / ETDA K3 - Whole blood *Black: 3.8% Sodium Citrate (1:4)- Whole blood *Blue: 3.2% Sodium Citrate (1:9)- Whole blood or Plasma *Green: Lithium Heparin / Sodium Heparin-Plasma *Grey: Glucose - Plasma Material:PET plastic or Glass Tube size :13*75mmï¼?13*100mm Volume:1ml,2ml,3ml,4ml,5ml,6ml,7ml Etc Shelf Life:2years Disinfecting Type:gamma ray Sterilized:yes Band:Chaoran Sample:Availible OEM:Available Certificate:CE/ISO
Vacutainer Serum tubes are used to obtain a serum sample. The tubes are available in plastic, a range of sizes and can be identified by a red cap. The BD Vacutainer serum tubes have the additive silica sprayed on the inner walls of the tube to accelerate the clotting process.
Venous Blood Collection Tube Whole Blood Tube K2 EDTA Additive 16 X 100 mm 10 mL Lavender BD Hemogard Closure Plastic Tube UOM: 1000/CS Product Number: 366643 Manufacturer: BD
Microtainer Capillary Blood Collection Tube Hematology K2 EDTA Additive 15.3 X 46 mm 250 µL to 500 µL Lavender BD Microgard Closure Plastic Tube UOM: 200/CS Product Number: 365974 Manufacturer: BD
EDTA salts (ethylene diamine tetra acetic acid) are used for the anticoagulation of whole blood for haematological investigations as the cellular components of the blood are particularly well preserved by EDTA. It works as an anticoagulant as it forms complexes with metal ions such as calcium, therefore inhibiting the coagulation cascade. Anticoagulation with EDTA is irreversible. The EDTA concentration in tubes is LYBCON Vacutainer 1.8mg per ml of complete blood when the fill level is correct, as recommended by the ICSH (International Council Society of Haematology) and the CLSI (Clinical and Laboratory standards institute). The institutes recommend dipotassium EDTA salt (K EDTA) for 2 haematological investigation. K EDTA is used in 2 LYBCON Vacutainer tubes in spray dried form.
Sterile Vacuum blood collection tube for single use: Sizes: 1ml, 2ml, 3ml;, 5ml, 10ml. SPEC: non-additive, additive. Product structure: test tube, piston, plastic cap. Product instruction: The products are made by medical glass, or highly transparent medical plastic materials. The products are matched with vacuum blood collection sets, and used as per the theory of negative pressure, and suck blood into the storage tube by the connecting tube, and can step the way of one vacuum blood collection needle with more storage tubes. Technical indication: Additive dosage of the products are accurate, blood sample capacities are also accurate. Scope for use: The products are used for collecting blood in clinic
CE&ISO certified manufacturer of medical supplies medical lab consumables since2009, Vacuum blood collection tubes are applicable to the clinical blood test and suitable for the blood cells analysis The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to analytical testing *Red: Non-additive Serum *Red: Clot Activator Serum *Yellow: Gel & Clot Activator Serum *Purple: ETDA K2 / ETDA K3 Whole blood *Black: 3.8% Sodium Citrate (1:4) Whole blood *Blue: 3.2% Sodium Citrate (1:9) Whole blood or Plasma *Green: Lithium Heparin / Sodium Heparin Plasma *Grey: Glucose Plasma Material:PET plastic or Glass Tube size :13*75mm,13*100mm Volume:1ml,2ml,3ml,4ml,5ml,6ml,7ml Etc Shelf Life:2years Disinfecting Type:gamma ray Sterilized:yes Brand:Chaoran Sample:Availible OEM:Available Certificate:CE/ISO
K3 EDTA VACUUM TUBE, Available In 13*75(2 Ml,3ml,4ml), 13*100( 5ml, 6ml) With Gama Sterilization And Also Non-Sterilization. With Purple Cap Tube Which Is Use For The Hematology Test In Pathology Laboratory, Its Primary Use Is For The C.B.C And Individual Components Of The C.B.C