CE&ISO certified professional manufacturer of medical supplies lab consumables vacutainer since2009-Hebei Chaoran Medical Instruments
Vacuum blood collection tubes are applicable to the clinical blood test and the blood cells analysis
The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to
analytical testing
*Red: Non-additive - Serum
*Red: Clot Activator-Serum
*Yellow: Gel & Clot Activator -Serum
*Purple: ETDA K2 / ETDA K3 - Whole blood
*Black: 3.8% Sodium Citrate (1:4)- Whole blood
*Blue: 3.2% Sodium Citrate (1:9)- Whole blood or Plasma
*Green: Lithium Heparin / Sodium Heparin-Plasma
*Grey: Glucose - Plasma
Material:PET plastic or Glass
Tube size :13*75mmï¼?13*100mm
Volume:1ml,2ml,3ml,4ml,5ml,6ml,7ml Etc
Shelf Life:2years
Disinfecting Type:gamma ray
Sterilized:yes
Band:Chaoran
Sample:Availible
OEM:Available
Certificate:CE/ISO
CE&ISO certified professional manufacturer of medical supplies lab consumables vacutainer since2009-Hebei Chaoran Medical Instruments Vacuum blood collection tubes are applicable to the clinical blood test and the blood cells analysis The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to analytical testing *Red: Non-additive - Serum *Red: Clot Activator-Serum *Yellow: Gel & Clot Activator -Serum *Purple: ETDA K2 / ETDA K3 - Whole blood *Black: 3.8% Sodium Citrate (1:4)- Whole blood *Blue: 3.2% Sodium Citrate (1:9)- Whole blood or Plasma *Green: Lithium Heparin / Sodium Heparin-Plasma *Grey: Glucose - Plasma Material:PET plastic or Glass Tube size :13*75mm 13*100mm Volume:1ml,2ml,3ml,4ml,5ml,6ml,7ml Etc Shelf Life:2years Disinfecting Type:gamma ray Sterilized:yes Band:Chaoran Sample:Availible OEM:Available Certificate:CE/ISO
LYBCON Vacutainer GEL-SST Advance tubes During the centrifugation of the LYBCON Vacutainer GEL-SST Advance tubes, an inert LYBCON Vacutainer gel separates the serum and the blood clot preventing the contamination of the serum from the separated cellular components. For example, the serum for certain analytes such as potassium, phosphorus and glucose must be separated from the cells within a few hours - otherwise the results will be significantly distorted. Using LYBCON GEL-SST Advance tubes routine analyses in clinical chemistry such as potassium and glucose are still stable after a week of storage at 2-8 C. Clinical evaluations of special chemistry demonstrate a high degree of analyte stability with the acrylic gel in the LYBCON GEL-SST Advance, with detection of >90% of the therapeutic drugs and other special analytes(proteins/peptides, steroids and vitamins) tested. As a result of the type of gel used in the GEL-SST Advance tubes, LYBCON Vacutainer short centrifugation times of 5 minutes at 3000g can be achieved. The stability of the gel barrier is a distinct advantage during transport and storage. The main advantages of gel tubes versus non-gel tubes are: Stable barrier between serum and clotted blood, therefore better analyse stability. Better sample quality. Optimisation of the work flow: Short centrifugation time, sample processing and archiving in the primary tube. No possibility of misidentification due to the use of secondary tubes. CLOTTING TIMES The minimum recommended coagulation time for GEL-SST Advance tubes for patients who have not LYBCON Vacutainer received anticoagulation treatment is 30 minutes. CENTRIFUGING CONDITIONS 1600-2000g for 10 minutes MIXING RECOMMENDATION Serum Separation Tubes should be gently inverted 180 and back 6-8 times. EFFECTS OF TEMPERATURE LYBCON Vacutainer GEL-SST Advance should be stored at 4-25C and protected from direct sunlight during storage. Cooling of the tube by or during centrifuging can affect the movement capability of the gel. The optimum separation of serum and coagulated blood is achieved at a temperature of 20-25C. Serum Separation Tubes should be gently inverted 180 and back 6-8 times. CLOT ACTIVATOR LYBCON Vacutainer GEL-SST Advance tubes contain silica particles. SPECIFICATION Specimen: Serum Additive: Gel & Clot Activator Cap color: Dark yellow Tube Size: 13x75mm Draw Volume: 3.5mL Max. draw volume Tolerance: ±10%
1. Current overload or line surge shutdown 2. High temperature compressor shutdown. 3. High pressure alarm shutdown. 4. Low pressure alarm shutdown. 5. Low oxygen cocentrator alarm. Oxygen concentrator: 0.5-5L/min Purity: 95%+_3% Working system Continuous Power Supply AC230V.50Hz/AC220V.60HZ AC120V.60Hz Power: 390VA Net Weight: 16kg( Gross weight: 18.5kgs) Warranty: Long-life compressor designed for 1000 hours of maintenance-free use. Size: 33*26*54cm
3ply face mask comfortable for user. The face mask is latex free and use brand new hypoallergenic material, odourless and lint free. Product Disposable 3-Ply Non-Woven Face Mask with Ear Loop Size 18cm x 9.5cm (18cm after expended) Color Blue/Green/White/Yellow/Pink or can be customized Outer Layer Spund-bound PP Nonwoven: 20 - 25 gsm Filter Medium Meltblown PP Nonwoven: 18 - 20gsm Inner Layer Lint free ES Nonwoven: 25 gsm Nose Piece Aluminum Packaging 50 pieces per box or 50pcs per bag; 10 boxes/bags per carton. 1600 cartons/20 ft container , 3200 carton/40 HQ container. MOQ 50,000 pieces min order Quantity: 10,000PCS/Day MOQ : 10,000 pieces Packaging: 50 pieces per box/bag; 40 boxes per carton. Payment condition: TT Shipping Duration: 7 Days ( ONE WEEK) Origin: Thailand/China Condition: Subject to availability
Product Name Fashion Consumable Personal Protection Particulate N95 Mask Material Non woven fabric+ Melt Blown Filter+ Non Woven Fabric Shape Molded Cup/Cone Application Farm buildings, Mining, Weaving,Polishing,Pharmacy,Hardware,Cement Size 190*130mm Carton size 310*200*145mm Packing details 50pcs/Carton Product's details Adjustable aluminum nose clip to offer better fit
Non-Sterile Medical Examination Nitrile Gloves Powder free & Latex free 100% Virgin raw materials with FDA certificate & as per ASTM D6319/ CE EN 455 Quality standard: ASTM D6319, with 510K and FDA, CE/EN455, Color: Blue, white Finger Tips: textured Cuff: Beaded Pcs per Box for S/M/L/XL : 100pcs/box Origin: China, Vietnam, Thailand, Malaysia Benefits Protection from unwanted and harmful substances Beaded Cuff ensures easy donning and prevent roll down Superior Strength with better Puncture resistance Finger Tip Textured enhances wet and dry grip Thinner Guage improves tactile senstivity Custom Design enhances comfort and fit Provide an Alternate Solution for individual who are allergic to natural rubber latex Material : Synthetic Nitrile Type : Non-Sterile Powder Free, Amibidextrous, Finger Tip Textured, beaded cuff. Storage: Store in a dry and cool place, the temperature not higher than 38�° C Shelf life: 2 years Physical Properties Tensile Strength: Before Aging 14Mpa min Tensile Strength: After Aging 14Mpa min Elongation at Break (%): Before aging 500% min Elongation at Break (%): After aging 400% min Length: 230 mm in XS, S, M, L, XL Width: 70+/- 10 (XS) Width: 80+/- 10 (S) Width: 95+/- 10 (M) Width: 110+/- 10 (L) Width: 120+/- 10 (XL) Thickness Single wall ( mm): Fingers 0.050mm min Thickness Single wall ( mm): Palm 0.050mm min
Also known as Serum separating tubes Gel separates the serum and the blood clot during centrifugation of the GEL-SST Advance tubes, preventing the serum from being affected by the separated cellular components. Material: PET & PP Type of Additive: Silicone Gel & clot activator Size: 13X75 mm, 13X100mm Capacity: 3.5mL, 4mL, 5mL, 6mL Available in: Vacuum and Non-Vacuum Colour Code: Yellow Available Packaging: Inner Packaging 100 pieces, Outer Carton Packaging 1200 pieces Used for: Endocrinology, Toxicology, Microbiology, Immunology & urea test C reactive protein test * Serum Separation Tubes should be gently inverted 180 and back 6-8 times