CE&ISO certified professional manufacturer of medical supplies lab consumables vacutainer since2009-Hebei Chaoran Medical Instruments
Vacuum blood collection tubes are applicable to the clinical blood test and the blood cells analysis
The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to
analytical testing
*Red: Non-additive - Serum
*Red: Clot Activator-Serum
*Yellow: Gel & Clot Activator -Serum
*Purple: ETDA K2 / ETDA K3 - Whole blood
*Black: 3.8% Sodium Citrate (1:4)- Whole blood
*Blue: 3.2% Sodium Citrate (1:9)- Whole blood or Plasma
*Green: Lithium Heparin / Sodium Heparin-Plasma
*Grey: Glucose - Plasma
Material:PET plastic or Glass
Tube size :13*75mm 13*100mm
Volume:1ml,2ml,3ml,4ml,5ml,6ml,7ml Etc
Shelf Life:2years
Disinfecting Type:gamma ray
Sterilized:yes
Band:Chaoran
Sample:Availible
OEM:Available
Certificate:CE/ISO
CE&ISO certified professional manufacturer of medical supplies lab consumables vacutainer since2009-Hebei Chaoran Medical Instruments Vacuum blood collection tubes are applicable to the clinical blood test and the blood cells analysis The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to analytical testing *Red: Non-additive - Serum *Red: Clot Activator-Serum *Yellow: Gel & Clot Activator -Serum *Purple: ETDA K2 / ETDA K3 - Whole blood *Black: 3.8% Sodium Citrate (1:4)- Whole blood *Blue: 3.2% Sodium Citrate (1:9)- Whole blood or Plasma *Green: Lithium Heparin / Sodium Heparin-Plasma *Grey: Glucose - Plasma Material:PET plastic or Glass Tube size :13*75mmï¼?13*100mm Volume:1ml,2ml,3ml,4ml,5ml,6ml,7ml Etc Shelf Life:2years Disinfecting Type:gamma ray Sterilized:yes Band:Chaoran Sample:Availible OEM:Available Certificate:CE/ISO
LYBCON Vacutainer GEL-SST Advance tubes During the centrifugation of the LYBCON Vacutainer GEL-SST Advance tubes, an inert LYBCON Vacutainer gel separates the serum and the blood clot preventing the contamination of the serum from the separated cellular components. For example, the serum for certain analytes such as potassium, phosphorus and glucose must be separated from the cells within a few hours - otherwise the results will be significantly distorted. Using LYBCON GEL-SST Advance tubes routine analyses in clinical chemistry such as potassium and glucose are still stable after a week of storage at 2-8 C. Clinical evaluations of special chemistry demonstrate a high degree of analyte stability with the acrylic gel in the LYBCON GEL-SST Advance, with detection of >90% of the therapeutic drugs and other special analytes(proteins/peptides, steroids and vitamins) tested. As a result of the type of gel used in the GEL-SST Advance tubes, LYBCON Vacutainer short centrifugation times of 5 minutes at 3000g can be achieved. The stability of the gel barrier is a distinct advantage during transport and storage. The main advantages of gel tubes versus non-gel tubes are: Stable barrier between serum and clotted blood, therefore better analyse stability. Better sample quality. Optimisation of the work flow: Short centrifugation time, sample processing and archiving in the primary tube. No possibility of misidentification due to the use of secondary tubes. CLOTTING TIMES The minimum recommended coagulation time for GEL-SST Advance tubes for patients who have not LYBCON Vacutainer received anticoagulation treatment is 30 minutes. CENTRIFUGING CONDITIONS 1600-2000g for 10 minutes MIXING RECOMMENDATION Serum Separation Tubes should be gently inverted 180 and back 6-8 times. EFFECTS OF TEMPERATURE LYBCON Vacutainer GEL-SST Advance should be stored at 4-25C and protected from direct sunlight during storage. Cooling of the tube by or during centrifuging can affect the movement capability of the gel. The optimum separation of serum and coagulated blood is achieved at a temperature of 20-25C. Serum Separation Tubes should be gently inverted 180 and back 6-8 times. CLOT ACTIVATOR LYBCON Vacutainer GEL-SST Advance tubes contain silica particles. SPECIFICATION Specimen: Serum Additive: Gel & Clot Activator Cap color: Dark yellow Tube Size: 13x75mm Draw Volume: 3.5mL Max. draw volume Tolerance: ±10%
This tubes have silica particles added to trigger the coagulation within an acceptable time Material: PET & PP Type of Additive: Clot Activator Size: 13X75 mm, 13X100mm Capacity: 1 mL, 2mL, 3mL, 4mL and 6mL Available in: Vacuum and Non Vacuum Colour Code: Red Available Packaging: Inner Packaging 100 pieces, Outer Carton Packaging 1200 pieces Used for: Chemistry enzymes, electrolyte Immunology presence of antibodies to a pathogen Serology protein made by human immune system Blood bank cross matching of blood types.
Also known as Serum separating tubes Gel separates the serum and the blood clot during centrifugation of the GEL-SST Advance tubes, preventing the serum from being affected by the separated cellular components. Material: PET & PP Type of Additive: Silicone Gel & clot activator Size: 13X75 mm, 13X100mm Capacity: 3.5mL, 4mL, 5mL, 6mL Available in: Vacuum and Non-Vacuum Colour Code: Yellow Available Packaging: Inner Packaging 100 pieces, Outer Carton Packaging 1200 pieces Used for: Endocrinology, Toxicology, Microbiology, Immunology & urea test C reactive protein test * Serum Separation Tubes should be gently inverted 180 and back 6-8 times
Supplier: Syringe, infusion set, blood collection tube, vacutainer needle, auto disable syringe, safety syringe, kn95 face mask, n95 face mask, face mask and isolation gown, protection gown, surgical gown, blood transfusion set...etc.
Usage: Can be added into a vacuum blood collection tube, which can be used in clinical medical inspection work. The laboratory personnel can complete operations such as taking blood samples, quickly separating serum and transferring samples in the same vessel. Characteristics: 1. Desheng has a professional R&D team for blood collection tube additives, and has professional solutions for the problem of coagulants; 2. It can effectively promote coagulation in a short period of time, the blood clot will fully shrink, avoid the formation of fibrin clots, and extract high-quality complete serum samples; 3. The unique core technology solves the hidden hemolysis problem of blood cell coagulation and rupture, and meets the needs of rapid outpatient and emergency serum biochemical testing; 4. Use silicon as the main component, it will not interfere with the enzyme index and ensure the accuracy of detection.
Non Vacuum Blood Tube Item GDN050EK3, Specification: 5ml EDTA K3 Non-vacuum blood collection tube, Green cap, Item GDN050EK2, Specification: 5ml EDTA K2 Non-vacuum blood collection tube, Green cap, Item GDN050A, Specification: 5ml Plain Non-vacuum blood collection tube, Red cap, Item GDN050CA, Specification: 5ml Clot Activator Non-vacuum blood collection tube, Red cap, Item GDN050SP, Specification: 5ml Fluoride Oxalate Non-vacuum blood collection tube, Yellow cap, Item GDN050LH, Specification: 5ml Lithium Heparin Non-vacuum blood collection tube, Dark Blue cap
The tubes are designed for blood The tubes are designed for blood LYBCON Vacutainer sedimentation without the use of sedimentation pipettes. The blood is taken directly into the tubes and LYBCON Vacutainer turned end-over-end 8-10 times. Immediately before the tubes are placed in the stand for measurement, LYBCON Vacutainer the tubes must be mixed again. After one or two hours the results are read. The stand holds a LYBCON Vacutainer maximum of 10 tubes and has a height Lybcon adjustable zero mark. The measurement results achieved correspond to the Westergren method. MIXING RECOMMENDATION ESR (Erythrocyte Sedimentation Rate) tubes should be gently inverted 180 and back 8-10 times. SPECIFICATION Specimen: Whole Additive: Sodium citrate 3.8% (4NC) Cap color: Black Tube Size: 13x75mm Draw Volume: 1.6mL, 1.8mL Max. draw volume Tolerance: ±10% sedimentation without the use of sedimentation pipettes. The blood is taken directly into the tubes and LYBCON Vacutainer turned end-over-end 8-10 times. Immediately before the tubes are placed in the stand for measurement, LYBCON Vacutainer the tubes must be mixed again. After one or two hours the results are read. The stand holds a LYBCON Vacutainer maximum of 10 tubes and has a height LYBCON Vacutainer adjustable zero mark. The measurement results achieved correspond to the Westergren method. MIXING RECOMMENDATION ESR (Erythrocyte Sedimentation Rate) tubes should be gently inverted 180 and back 8-10 times. SPECIFICATION Specimen: Whole Additive: Sodium citrate 3.8% (4NC) Cap color: Black Tube Size: 13x75mm Draw Volume: 1.6mL, 1.8mL Max. draw volume Tolerance: ±10%
CE&ISO certified professional manufacturer of medical supplies lab consumables vacutainer since2009-Hebei Vacuum blood collection tubes are applicable to the clinical blood test and the blood cells analysis The internal walls of the tubes are coated with different additives designed to stabilize and preserve the specimen prior to analytical testing *Red: Non-additive - Serum *Red: Clot Activator-Serum *Yellow: Gel & Clot Activator -Serum *Purple: ETDA K2 / ETDA K3 - Whole blood *Black: 3.8% Sodium Citrate (1:4)- Whole blood *Blue: 3.2% Sodium Citrate (1:9)- Whole blood or Plasma *Green: Lithium Heparin / Sodium Heparin-Plasma *Grey: Glucose - Plasma