Product Details: Brand : CTK BioTech Samples : Serum Storage : 2-8 C Size : 96 Well Cat. No. : E1025 The Total Thyroxine (T4) ELISA is a solid-phase enzyme-linked immunosorbent assay based on the principle of the competitive ELISA technique for quantitative determination of Thyroxine in human serum. The three main kit components are: 1) Solid microwells pre-coated with anti-T4 2) T4 Calibrators 3) Liquid T4 Enzyme Conjugate Mixture comprised of T4 labelled with horseradish peroxidase (T4-HRP) Product Freature: Analytical Sensitivity: 176 aµg/dL at 2-SD Specificity: No cross-reactivity or interference with d-Thyroxine 10 aµg/mL d-Triiodothyronine 100 aµg/mL Iodotyrosine 100 aµg/mL Diiodotyrosine 100 aµg/mL TBG 50 aµg/mL Human Albumin 50 aµg/mL Phenylbutazone 25 aµg/mL Phenytoin 50 aµg/mL ASA 500 aµg/mL Acetaminophen 500 aµg/mL Accuracy: correlation coefficient 0.98 with a reference method Intra Assay Precision: CV a?¤ 5.9% Inter Assay Precision: CV a?¤ 7.6% Product Specification : Anti-T4 Ab Coated Microwells Total T4 Calibrators: C1 (0 ng/mL) C2 (2.0 ng/mL) C3 (5.0 ng/mL) C4 (10.0 ng/mL) C5 (15.0 ng/mL) C6 (25.0 ng/mL) Total T4 Assay Control Total T4 Enzyme Concentrate Enzyme Buffer Wash Buffer Concentrate TMB Substrate Stop Solution Product Insert
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Brand : CTK BioTech Sample Material : Serum Storage : 2-8 C Cat. No : E1015 Total T3 ELISA CE The Total Triiodothyronine (T3) ELISA is a solid-phase enzyme-linked immunosorbent assay based on the principle of the competitive ELISA technique for quantitative determination of Triiodothyronine in human serum. The three main kit components are: 1) Solid microwells pre-coated with anti-T3 2) T3 Calibrators 3) Liquid T3 Enzyme Conjugate Mixture comprised of T3 labelled with horseradish peroxidase (T3-HRP) Product Features: Analytical Sensitivity: 173 ng/mL at 2-SD Specificity: No cross-reactivity or interference with d-Thyroxine 10 aµg/mL d-Triiodothyronine 100 aµg/mL Iodotyrosine 100 aµg/mL Diiodotyrosine 100 aµg/mL TBG 50 aµg/mL Human Albumin 50 aµg/mL Phenylbutazone 25 aµg/mL Phenytoin 50 aµg/mL ASA 500 aµg/mL Acetaminophen 500 aµg/mL Accuracy: correlation coefficient 0.99 with a reference method Intra Assay Precision: CV a?¤ 7.5% Inter Assay Precision: CV a?¤ 10.76% Product Specification : Anti-T3 Ab Coated Microwells Total T3 Calibrators: C1 (0 ng/mL) C2 (0.5 ng/mL) C3 (1.0 ng/mL) C4 (2.0 ng/mL) C5 (4.0 ng/mL) C6 (8.0 ng/mL) Total T3 Assay Control Total T3 Enzyme Concentrate Enzyme Buffer Wash Buffer Concentrate TMB Substrate Stop Solution Product Insert
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Brand : CTK BioTech Sample ; Serum Storage : 2-8 C Cat No : E1030 The RecombiLISA TSH ELISA is a solid phase enzyme linked immunosorbent assay for the quantitative determination of the levels of Thyroid Stimulating Hormone (TSH) in human serum. The RecombiLISA TSH ELISA is intended for professional use as an aid in the diagnosis of thyroid dysfunction. TSH values should not be the only factor in the determination of thyroid status, and all other available clinical and epidemiological information should be considered for an accurate diagnosis. Recommended for use: Any person presenting with signs or symptoms of hypo or hyperthyroidism Any person presenting with an enlarged thyroid gland (goiter) Pregnant women for first trimester screening Any person requiring regular monitoring of treatment Normally, thyroid function is first assessed by detection of TSH levels in the blood. The monoclonal anti-TSH antibody coated on the surface of the microwells specifically recognizes the junction between the �± and �² subunits. The HRP-conjugated monoclonal anti-TSH antibody detects the �² subunit only. Combining the measurement of TSH with the thyroid hormones (T3/T4) can provide more information for the determination of thyroid status. Product Features : Sensitivity: Detects TSH levels as low as 0.035 �µIU/mL Specificity: No cross reactivity detected with related hormones: FSH, LH and hCG Linearity: 1:128 dilution on 36 IU/mL sample Precision: intra assay precision: CV 7.5%; inter assay precision: CV 8.0 % Accuracy: R2= 0.986 against Roche TSH Chemiluminescence Immunoassay Hook effect: No hook effect up to 8000 IU/mL Interference: not affected by Hemoglobin 500mg/dL, Diltiazem 15uM, Bilirubin 20 mg/dL, Erythromycin 81.6uM, Triglycerides 3g/dL, Verapamil 4.4uM, HAMA 52.5ng/mL, T3 100ng/mL, RF 215IU/mL, T4 100ug/dL, Acetaminophen 1324uM Calibration: Human TSH WHO 3rd International Standards (81/565 NIBSC) Calibrators: 0, 0.5, 2.0, 5.0, 10, 20, 40 �µIU/mL in biological matrix Shelf life: 18 months Assay time: 80 minutes. Product Specifications: Anti-TSH Ab coated microwells TSH standard S1 TSH standard S2 TSH standard S3 TSH standard S4 TSH standard S5 TSH standard S6 TSH standard S7 HRP-anti-TSH conjugates TMB substrate Wash buffer (30X concentrate) Stop solution ELISA working sheet Product insert
Product Details: Brand : CTK BIOTECH Size : 96 Well Specimen : Serum & Plasma stored at 2 - 8 C Cat No : E0100 The RecombiLISA HAV IgM ELISA is a solid-phase enzyme-linked immunosorbent assay for the qualitative detection of IgM anti-hepatitis A virus in human serum or plasma. Product Features: Utilizes IgM capture technique Detects IgM anti-HAV in serum or plasma Evaluated with BBI HAV serum conversion and HAV mixed titer performance panels Useful for identifying acute HAV infections Product Specification: Microwells coated with anti-human IgM antibody HAV IgM negative control HAV IgM positive control HRP-HAV conjugates Wash buffer (30 x concentrate) TMB substrate A TMB substrate B Stop solution ELISA Working Sheet Product insert
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Brand : CTK BioTech Sample Material : Plasma/Serum Storage : 2-8 C Cat. No : E0105 INTENDED USE: The RecombiLISA HEV IgM ELISA is a solid-phase enzyme-linked immunosorbent assay for the qualitative detection of anti-hepatitis E virus (HEV) IgM in human serum or plasma. It is intended for professional use only and to be used as an aid in the diagnosis of infection with HEV. TEST PRINCIPLE: The RecombiLISA HEV IgM ELISA is a solid-phase enzyme-linked immunosorbent assay based on the principle of the IgM capture technique for the detection of antiHEV IgM in human serum or plasma. The RecombiLISA HEV IgM ELISA is composed of two key components: 1) Solid microwells pre-coated with polyclonal anti-human IgM antibody 2) Liquid conjugate composed of HEV antigen conjugated with horseradish peroxidase (HRP-HEV Conjugate) During the assay, the test specimen is first incubated in the coated microwells. AntiHEV IgM, if present in the specimen, binds to the antibody coated on the microwell surface. Any unbound specimen is then removed by a wash step. During a second incubation with the HRP-HEV Conjugate, the anti-HEV IgM antibody is absorbed on the microwell surface which binds to the HRP-HEV Conjugate, forming a conjugate complex. Unbound conjugate is then removed by washing. After addition of the TMB substrate, the presence of conjugate complex is shown by development of a blue color resulting from a reaction between the enzyme and substrate. The reaction is then quenched by addition of the Stop Solution, and the absorbance value for each microwell is determined using a spectrophotometer at 450/620-690 nm. Clinical Performance: A total of 400 specimens from susceptible subjects were tested by the RecombiLISA HEV IgM ELISA and by a Chinese State Drug Administration (SFDA) licensed reference EIA. Clinical Performance: Relative Sensitivity: 100%, Relative Specificity: 100%, Overall Agreement: 100%.
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Brand : CTK BioTech Sample : serum or plasma Storage : 2-8 C Cat No : E0330 The RecombiLISA Leptospira IgM ELISA Kit is an indirect, solid phase enzyme-linked immunosorbent assay. The two main kit components are: 1) A 96 breakable well plate with the solid microwells pre-coated with L. interrogans antigen. 2) Liquid conjugates composed of monoclonal anti-human IgM reagent conjugated with horseradish peroxidase (HRP-anti-human IgM conjugates). This test is intended to be used for the qualitative detection of IgM anti-Leptospira interrogans (L. interrogans) in human serum or plasma. It is intended to be used by professionals as an aid in the diagnosis of acute infection with L. interrogans. Any interpretation or use of this test result must also rely on other clinical findings as well as on the professional judgment of health care providers. Recommended for use: Any person presenting with clinical signs or symptoms consistent with acute infection with interrogansincluding: high fever, headache, chills, muscle aches, vomiting, jaundice, red eyes, abdominal pain, diarrhea, skin rash After exposure to a known contaminated source Product Features : Sensitivity: 86.7% Specificity: 96.8% Cross Reactivity: No false positive results were observed on specimens from Dengue, Malaria, Typhi, ANA, HAMA, RF, HIV, HBsAg, HCV, Syphilis, pylori Interference: No interference was seen with substances: Salicylic acid: 4.34 mmol/L; Glucose: 55 mmol/L; Sodium citrate: 1.3 %;Heparin: 3,000 U/L; Creatinine: 5 mmol/L; Bilirubin: 10 mg/dL; EDTA: 3.4 �µmol/L Shelf life: 12 months Open vial stability: 8 weeks at 2-8 C, or until the expiration date Kit Components : Microwells coated with recombinant L. interrogans antigens Lepto IgM positive control Lepto IgM negative control Sample diluent HRP anti-human IgM conjugate Wash buffer (30 x concentrate) TMB substrate A TMB substrate B Stop solution ELISA Working Sheet Product insert
Cat.No - TO-E0006 Size - 96T Price - 39375
Covid-19 Self Test Kit We are the authorized first vendor of ADTech! KFDA CE approved, FDA Pending Price : Negotiable Pre-Clinical Test Report Accuracy - In total samples 93.3% (14/15) - In positive samples 91.7% (11/12) 1. Pre-Clinical Test summary 1) Pre-clinical test is fulfilled by Domestic large clinical laboratory with ADTech COVID-19 IgM/IgG RAPID KIT 2) Tests are made by total 15 samples with 12 positive and 3 negative samples 3) Clinical Laboratory tested the sample with Immunofluorescence Analysis 2. Pre-clinical test result 1) Samples were tested by ADTech COVID-19 IgM/IgG RAPID KIT 2) Test result by ADTechs RAPID KIT - 4 negatives and 11 positives results in 15 samples 3) Comparison between Immunofluorescence analysis and ADTechs RAPID KIT - 14 test results are same(including negative and positive results) - 1 samples test result are different(Positive Negative by ADTech
Elisa kit Available in Various Parameters mainly HIV1, 2, HCV, HBs Ag In 36,48,96 tests packing
Cat.No - TO-E0010 Size - 96T Price - 39375
Cat.No - TO-E0013 Size - 96T Price - 39375
Cat.No - TO-E0012 Size - 96T Price - 39375
Cat.No - TO-E0009 Size - 96T Price - 39375
Cat.No - TO-E0015 Size - 96T Price - 39375
Cat.No - TO-E0001 Size - 96T Price - 39375
Cat.No - TO-E0011 Size - 96T Price - v
Cat.No - DR-E0006 Size - 96T Price - 39375
Cat.No - DR-E0008 Size - 96T Price - 39375
Cat.No - DR-E0013 Size - 96T Price - 39375
Cat.No - DR-E0007 Size - 96T Price - 39375