Product Details:
Number of Reactions(Preps)/Kit : 96 Wells
Brand : CTK BioTech
Sample Material : Serum
Storage : 2-8 C
Cat. No : E1015
Total T3 ELISA CE
The Total Triiodothyronine (T3) ELISA is a solid-phase enzyme-linked immunosorbent assay based on the principle of the competitive ELISA technique for quantitative determination of Triiodothyronine in human serum.
The three main kit components are:
1) Solid microwells pre-coated with anti-T3
2) T3 Calibrators
3) Liquid T3 Enzyme Conjugate Mixture comprised of T3 labelled with horseradish peroxidase (T3-HRP)
Product Features:
Analytical Sensitivity: 173 ng/mL at 2-SD
Specificity: No cross-reactivity or interference with
d-Thyroxine 10 aµg/mL
d-Triiodothyronine 100 aµg/mL
Iodotyrosine 100 aµg/mL
Diiodotyrosine 100 aµg/mL
TBG 50 aµg/mL
Human Albumin 50 aµg/mL
Phenylbutazone 25 aµg/mL
Phenytoin 50 aµg/mL
ASA 500 aµg/mL
Acetaminophen 500 aµg/mL
Accuracy: correlation coefficient 0.99 with a reference method
Intra Assay Precision: CV a?¤ 7.5%
Inter Assay Precision: CV a?¤ 10.76%
Product Specification :
Anti-T3 Ab Coated Microwells
Total T3 Calibrators:
C1 (0 ng/mL)
C2 (0.5 ng/mL)
C3 (1.0 ng/mL)
C4 (2.0 ng/mL)
C5 (4.0 ng/mL)
C6 (8.0 ng/mL)
Total T3 Assay Control
Total T3 Enzyme Concentrate
Enzyme Buffer
Wash Buffer Concentrate
TMB Substrate
Stop Solution
Product Insert
Product Details: Brand : CTK BioTech Samples : Serum Storage : 2-8 C Size : 96 Well Cat. No. : E1025 The Total Thyroxine (T4) ELISA is a solid-phase enzyme-linked immunosorbent assay based on the principle of the competitive ELISA technique for quantitative determination of Thyroxine in human serum. The three main kit components are: 1) Solid microwells pre-coated with anti-T4 2) T4 Calibrators 3) Liquid T4 Enzyme Conjugate Mixture comprised of T4 labelled with horseradish peroxidase (T4-HRP) Product Freature: Analytical Sensitivity: 176 aµg/dL at 2-SD Specificity: No cross-reactivity or interference with d-Thyroxine 10 aµg/mL d-Triiodothyronine 100 aµg/mL Iodotyrosine 100 aµg/mL Diiodotyrosine 100 aµg/mL TBG 50 aµg/mL Human Albumin 50 aµg/mL Phenylbutazone 25 aµg/mL Phenytoin 50 aµg/mL ASA 500 aµg/mL Acetaminophen 500 aµg/mL Accuracy: correlation coefficient 0.98 with a reference method Intra Assay Precision: CV a?¤ 5.9% Inter Assay Precision: CV a?¤ 7.6% Product Specification : Anti-T4 Ab Coated Microwells Total T4 Calibrators: C1 (0 ng/mL) C2 (2.0 ng/mL) C3 (5.0 ng/mL) C4 (10.0 ng/mL) C5 (15.0 ng/mL) C6 (25.0 ng/mL) Total T4 Assay Control Total T4 Enzyme Concentrate Enzyme Buffer Wash Buffer Concentrate TMB Substrate Stop Solution Product Insert
Supplier: Ethanol /alcohol process line/machine,ethanol/alcohol turnkey project , industry fruit process machine/production line ,industry vegetable process machine/production line, industry noodle machine/production line , industry bread/cake machine/process line and so on . industry waste water treatment system process line .packing machine
Services: Our company's products, technical support, training, installation and commissioning
Supplier: Rapid detection kit, ribonucleic acid detection reagent, medical syringes, medical mask, medical ventilator, medical glove, medical isolation gown, surgical gown level 3+4, protective gown (overall ), oximeter, other medical products
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Brand : CTK BioTech Sample ; Serum Storage : 2-8 C Cat No : E1030 The RecombiLISA TSH ELISA is a solid phase enzyme linked immunosorbent assay for the quantitative determination of the levels of Thyroid Stimulating Hormone (TSH) in human serum. The RecombiLISA TSH ELISA is intended for professional use as an aid in the diagnosis of thyroid dysfunction. TSH values should not be the only factor in the determination of thyroid status, and all other available clinical and epidemiological information should be considered for an accurate diagnosis. Recommended for use: Any person presenting with signs or symptoms of hypo or hyperthyroidism Any person presenting with an enlarged thyroid gland (goiter) Pregnant women for first trimester screening Any person requiring regular monitoring of treatment Normally, thyroid function is first assessed by detection of TSH levels in the blood. The monoclonal anti-TSH antibody coated on the surface of the microwells specifically recognizes the junction between the �± and �² subunits. The HRP-conjugated monoclonal anti-TSH antibody detects the �² subunit only. Combining the measurement of TSH with the thyroid hormones (T3/T4) can provide more information for the determination of thyroid status. Product Features : Sensitivity: Detects TSH levels as low as 0.035 �µIU/mL Specificity: No cross reactivity detected with related hormones: FSH, LH and hCG Linearity: 1:128 dilution on 36 IU/mL sample Precision: intra assay precision: CV 7.5%; inter assay precision: CV 8.0 % Accuracy: R2= 0.986 against Roche TSH Chemiluminescence Immunoassay Hook effect: No hook effect up to 8000 IU/mL Interference: not affected by Hemoglobin 500mg/dL, Diltiazem 15uM, Bilirubin 20 mg/dL, Erythromycin 81.6uM, Triglycerides 3g/dL, Verapamil 4.4uM, HAMA 52.5ng/mL, T3 100ng/mL, RF 215IU/mL, T4 100ug/dL, Acetaminophen 1324uM Calibration: Human TSH WHO 3rd International Standards (81/565 NIBSC) Calibrators: 0, 0.5, 2.0, 5.0, 10, 20, 40 �µIU/mL in biological matrix Shelf life: 18 months Assay time: 80 minutes. Product Specifications: Anti-TSH Ab coated microwells TSH standard S1 TSH standard S2 TSH standard S3 TSH standard S4 TSH standard S5 TSH standard S6 TSH standard S7 HRP-anti-TSH conjugates TMB substrate Wash buffer (30X concentrate) Stop solution ELISA working sheet Product insert
Supplier: Hospital and horeca group disposable / consumable products, personal protections, mask n91 95 , nonwoven gowns, coveralls & medical towels, patient bibs, medical papers & converting roll services
Buyer: Airlaid wetlaid paper, medical papers, spunlace nonwoven
Supplier: Medical, surgical, industrial and paper products & chemicals