Product Details:
Brand : CTK BioTech
Samples : Serum
Storage : 2-8 C
Size : 96 Well
Cat. No. : E1025
The Total Thyroxine (T4) ELISA is a solid-phase enzyme-linked immunosorbent assay based on the principle of the competitive ELISA technique for quantitative determination of Thyroxine in human serum.
The three main kit components are:
1) Solid microwells pre-coated with anti-T4
2) T4 Calibrators
3) Liquid T4 Enzyme Conjugate Mixture comprised of T4 labelled with horseradish peroxidase (T4-HRP)
Product Freature:
Analytical Sensitivity: 176 aµg/dL at 2-SD
Specificity: No cross-reactivity or interference with
d-Thyroxine 10 aµg/mL
d-Triiodothyronine 100 aµg/mL
Iodotyrosine 100 aµg/mL
Diiodotyrosine 100 aµg/mL
TBG 50 aµg/mL
Human Albumin 50 aµg/mL
Phenylbutazone 25 aµg/mL
Phenytoin 50 aµg/mL
ASA 500 aµg/mL
Acetaminophen 500 aµg/mL
Accuracy: correlation coefficient 0.98 with a reference method
Intra Assay Precision: CV a?¤ 5.9%
Inter Assay Precision: CV a?¤ 7.6%
Product Specification :
Anti-T4 Ab Coated Microwells
Total T4 Calibrators:
C1 (0 ng/mL)
C2 (2.0 ng/mL)
C3 (5.0 ng/mL)
C4 (10.0 ng/mL)
C5 (15.0 ng/mL)
C6 (25.0 ng/mL)
Total T4 Assay Control
Total T4 Enzyme Concentrate
Enzyme Buffer
Wash Buffer Concentrate
TMB Substrate
Stop Solution
Product Insert
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Brand : CTK BioTech Sample Material : Serum Storage : 2-8 C Cat. No : E1015 Total T3 ELISA CE The Total Triiodothyronine (T3) ELISA is a solid-phase enzyme-linked immunosorbent assay based on the principle of the competitive ELISA technique for quantitative determination of Triiodothyronine in human serum. The three main kit components are: 1) Solid microwells pre-coated with anti-T3 2) T3 Calibrators 3) Liquid T3 Enzyme Conjugate Mixture comprised of T3 labelled with horseradish peroxidase (T3-HRP) Product Features: Analytical Sensitivity: 173 ng/mL at 2-SD Specificity: No cross-reactivity or interference with d-Thyroxine 10 aµg/mL d-Triiodothyronine 100 aµg/mL Iodotyrosine 100 aµg/mL Diiodotyrosine 100 aµg/mL TBG 50 aµg/mL Human Albumin 50 aµg/mL Phenylbutazone 25 aµg/mL Phenytoin 50 aµg/mL ASA 500 aµg/mL Acetaminophen 500 aµg/mL Accuracy: correlation coefficient 0.99 with a reference method Intra Assay Precision: CV a?¤ 7.5% Inter Assay Precision: CV a?¤ 10.76% Product Specification : Anti-T3 Ab Coated Microwells Total T3 Calibrators: C1 (0 ng/mL) C2 (0.5 ng/mL) C3 (1.0 ng/mL) C4 (2.0 ng/mL) C5 (4.0 ng/mL) C6 (8.0 ng/mL) Total T3 Assay Control Total T3 Enzyme Concentrate Enzyme Buffer Wash Buffer Concentrate TMB Substrate Stop Solution Product Insert
Supplier: Ethanol /alcohol process line/machine,ethanol/alcohol turnkey project , industry fruit process machine/production line ,industry vegetable process machine/production line, industry noodle machine/production line , industry bread/cake machine/process line and so on . industry waste water treatment system process line .packing machine
Services: Our company's products, technical support, training, installation and commissioning
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Brand : CTK BioTech Sample ; Serum Storage : 2-8 C Cat No : E1030 The RecombiLISA TSH ELISA is a solid phase enzyme linked immunosorbent assay for the quantitative determination of the levels of Thyroid Stimulating Hormone (TSH) in human serum. The RecombiLISA TSH ELISA is intended for professional use as an aid in the diagnosis of thyroid dysfunction. TSH values should not be the only factor in the determination of thyroid status, and all other available clinical and epidemiological information should be considered for an accurate diagnosis. Recommended for use: Any person presenting with signs or symptoms of hypo or hyperthyroidism Any person presenting with an enlarged thyroid gland (goiter) Pregnant women for first trimester screening Any person requiring regular monitoring of treatment Normally, thyroid function is first assessed by detection of TSH levels in the blood. The monoclonal anti-TSH antibody coated on the surface of the microwells specifically recognizes the junction between the �± and �² subunits. The HRP-conjugated monoclonal anti-TSH antibody detects the �² subunit only. Combining the measurement of TSH with the thyroid hormones (T3/T4) can provide more information for the determination of thyroid status. Product Features : Sensitivity: Detects TSH levels as low as 0.035 �µIU/mL Specificity: No cross reactivity detected with related hormones: FSH, LH and hCG Linearity: 1:128 dilution on 36 IU/mL sample Precision: intra assay precision: CV 7.5%; inter assay precision: CV 8.0 % Accuracy: R2= 0.986 against Roche TSH Chemiluminescence Immunoassay Hook effect: No hook effect up to 8000 IU/mL Interference: not affected by Hemoglobin 500mg/dL, Diltiazem 15uM, Bilirubin 20 mg/dL, Erythromycin 81.6uM, Triglycerides 3g/dL, Verapamil 4.4uM, HAMA 52.5ng/mL, T3 100ng/mL, RF 215IU/mL, T4 100ug/dL, Acetaminophen 1324uM Calibration: Human TSH WHO 3rd International Standards (81/565 NIBSC) Calibrators: 0, 0.5, 2.0, 5.0, 10, 20, 40 �µIU/mL in biological matrix Shelf life: 18 months Assay time: 80 minutes. Product Specifications: Anti-TSH Ab coated microwells TSH standard S1 TSH standard S2 TSH standard S3 TSH standard S4 TSH standard S5 TSH standard S6 TSH standard S7 HRP-anti-TSH conjugates TMB substrate Wash buffer (30X concentrate) Stop solution ELISA working sheet Product insert
Supplier: Rapid detection kit, ribonucleic acid detection reagent, medical syringes, medical mask, medical ventilator, medical glove, medical isolation gown, surgical gown level 3+4, protective gown (overall ), oximeter, other medical products
Supplier: Hospital and horeca group disposable / consumable products, personal protections, mask n91 95 , nonwoven gowns, coveralls & medical towels, patient bibs, medical papers & converting roll services
Buyer: Airlaid wetlaid paper, medical papers, spunlace nonwoven
Supplier: Medical, surgical, industrial and paper products & chemicals
Product Details: Brand : CTK BIOTECH Size : 96 Well Specimen : Serum & Plasma stored at 2 - 8 C Cat No : E0100 The RecombiLISA HAV IgM ELISA is a solid-phase enzyme-linked immunosorbent assay for the qualitative detection of IgM anti-hepatitis A virus in human serum or plasma. Product Features: Utilizes IgM capture technique Detects IgM anti-HAV in serum or plasma Evaluated with BBI HAV serum conversion and HAV mixed titer performance panels Useful for identifying acute HAV infections Product Specification: Microwells coated with anti-human IgM antibody HAV IgM negative control HAV IgM positive control HRP-HAV conjugates Wash buffer (30 x concentrate) TMB substrate A TMB substrate B Stop solution ELISA Working Sheet Product insert
Product Details: Number of Reactions(Preps)/Kit : 96 Wells Brand : CTK BioTech Sample Material : Plasma/Serum Storage : 2-8 C Cat. No : E0105 INTENDED USE: The RecombiLISA HEV IgM ELISA is a solid-phase enzyme-linked immunosorbent assay for the qualitative detection of anti-hepatitis E virus (HEV) IgM in human serum or plasma. It is intended for professional use only and to be used as an aid in the diagnosis of infection with HEV. TEST PRINCIPLE: The RecombiLISA HEV IgM ELISA is a solid-phase enzyme-linked immunosorbent assay based on the principle of the IgM capture technique for the detection of antiHEV IgM in human serum or plasma. The RecombiLISA HEV IgM ELISA is composed of two key components: 1) Solid microwells pre-coated with polyclonal anti-human IgM antibody 2) Liquid conjugate composed of HEV antigen conjugated with horseradish peroxidase (HRP-HEV Conjugate) During the assay, the test specimen is first incubated in the coated microwells. AntiHEV IgM, if present in the specimen, binds to the antibody coated on the microwell surface. Any unbound specimen is then removed by a wash step. During a second incubation with the HRP-HEV Conjugate, the anti-HEV IgM antibody is absorbed on the microwell surface which binds to the HRP-HEV Conjugate, forming a conjugate complex. Unbound conjugate is then removed by washing. After addition of the TMB substrate, the presence of conjugate complex is shown by development of a blue color resulting from a reaction between the enzyme and substrate. The reaction is then quenched by addition of the Stop Solution, and the absorbance value for each microwell is determined using a spectrophotometer at 450/620-690 nm. Clinical Performance: A total of 400 specimens from susceptible subjects were tested by the RecombiLISA HEV IgM ELISA and by a Chinese State Drug Administration (SFDA) licensed reference EIA. Clinical Performance: Relative Sensitivity: 100%, Relative Specificity: 100%, Overall Agreement: 100%.