Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity Icn: 4.5kA Release Type of Leakage Protection: Electronic Rated working current (In): 6-32A Rated working voltage (Ue): AC 230V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Residual current type: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic /Electromagnetic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230 Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life : 4000 Times Type of residual current: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity( Icn): 6kA Release Type of Leakage Protection: Electronic Rated working current In: 6-40A Rated working voltage (Ue): AC 230V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life :4000 Times Residual current type: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic /Electromagnetic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Type of residual current : A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N/3P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Type of residual current: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 4.5kA Release Type of Leakage Protection: Electronic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Residual current type: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 10kA Release Type of Leakage Protection: Electronic /Electromagnetic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Residual current type: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 6kA Release Type of Leakage Protection: Electronic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Residual current type: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N/3P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic Rated working current (In): 6-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Type of residual current : A/AC
An Earth Leakage circuit breaker (ELCB) (now referred to as residual current circuit breaker-RCCB) is a safety device used in electrical installation with high earth impedance to prevent shock. High Quality circuit breaker (ELCB’S) Manufacturer and Exporters provides Automatic models as well as manual models ELCB’s.
Earth leakage circuit breaker The elcb is micro controller based with shock guard which continuously displays all the parameters and with inbuilt seven segment display and indicates the reason for tripping. Dimensions 17.5x13.5x8 cm Weight 1.5kg approx
- USED ELCB - Made in Korea brands (Mixed : LS, Hyundai, Daco....) -15 ~ 30A - 8 ~10pcs/kg (FOB 4.9usd /kg)
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity: Icn 6kA Release Type of Leakage Protection: Electronic Rated working current : In 6-40A Rated working voltage : Ue AC 230V Rated operating frequency : 50/60Hz Rated insulation voltage Ui : 500V Rated residual operating current I â?³ n 10/30/100/300 mA Life: 4000 Times Residual current type: A/AC
The material and functions: 1. Hydrophilic non-woven: soft, make baby more comfortable. 2. Super Absorbent Polymer: Absorb the liquid effectively and instantly, keep surface dry all day to avoid wet back. 3. Blue Acquisition Distribution Layer: Make the liquid infiltrate quickly, prevent rewet and keep Baby's skin dry and clean. 4. Lamination film: breathable, prevent leakage and keep fresh. 5. PP tapes: go well with frontal tape, they can be used as many times as need. 6. Magic tapes/BIG ELASTIC EARS: can be used for many times, and big elastic ears are much more convenient for a better fit. 7. 3D rounder: avoid any side leakage. 8. Elastic waistband: Provide baby with a snug, comfortable circumstance. Pampers Diapers Huggies Diapers Earth's Best Diapers Pampers Newborn Pampers Maxi Pack Mini Pampers Maxi Pack Midi Pampers Maxi Pack Maxi Pampers Maxi Pack Maxi plus Pampers Giant pack Maxi Pampers Giant pack Maxi Pampers Giant pack Maxi plus
The material and functions: 1. Hydrophilic non-woven: soft, make baby more comfortable. 2. Super Absorbent Polymer: Absorb the liquid effectively and instantly, keep surface dry all day to avoid wet back. 3. Blue Acquisition Distribution Layer: Make the liquid infiltrate quickly, prevent rewet and keep Baby's skin dry and clean. 4. Lamination film: breathable, prevent leakage and keep fresh. 5. PP tapes: go well with frontal tape, they can be used as many times as need. 6. Magic tapes/BIG ELASTIC EARS: can be used for many times, and big elastic ears are much more convenient for a better fit. 7. 3D rounder: avoid any side leakage. 8. Elastic waistband: Provide baby with a snug, comfortable circumstance. Pampers Diapers Huggies Diapers Earth's Best Diapers Pampers Newborn Pampers Maxi Pack Mini Pampers Maxi Pack Midi Pampers Maxi Pack Maxi Pampers Maxi Pack Maxi plus Pampers Giant pack Maxi Pampers Giant pack Maxi Pampers Giant pack Maxi plus
Industrial electrical wires and cables, ups systems and ancillary, junction boxes, mccb, relays and various other electrical products and equipment..We believe in quality, cost effectiveness and timely service. we try to understand and do the best as per the client requirements.
High initial permeability, high output voltage, core size saving. Low core loss, good tolerance ability for large current impulse, good protection of Tripping of high current High cuire temperature, good temperature stability, -55~130, Competitive price
TERASAKI TEMPOWER ACB TYPES: AT06, AT16, AT12, AT20, AT25, AT32, AT40. TERASAKI TEMPOWER ACB Type AGR-11B,21B,22B,31B Overcurrent Protective Device) Types: AR208S, AR212S, AR216S, AR220S, AR325S, AR332S, AR440S, AR440SB, AR212H AR216H, AR220H, AR316H, AR320H, AR325H, AR332H, AR420H, AR440H.
VACCUM CIRCUIT BREAKER ALL TYPE OF ABB VACCUM CIRCUIT BREAKER VD4 12.12.25 , VD4 12.12.40, VD4 07.12.25.... MANY MORE 11 KV , 33KV . VD4Medium voltage vacuum circuit-breaker12 kV - 1250...4000 A - 63 kA36/40.5 kV - 630...3150 A - 16...40 kAMedium Voltage Products The VD4 are a synthesis of the renownedtechnology in designing and constructing vacuuminterrupters embedded in resin poles, and ofexcellency in design, engineering and productionof medium voltage circuit-breakers.Embedding the interrupter in resin makes thecircuit-breaker poles particularly sturdy andprotects the interrupter against shocks, accumula-tion of dust and humidity.The vacuum interrupter houses the contacts andmakes up the interrupting chamber.