Standard: IEC/EN61009-1 GB/T16917.1
Instantaneous trip type: B/C/D
The number of poles: 1P+N
Rated short circuit breaking capacity (Icn): 6kA
Release Type of Leakage Protection: Electronic
Rated working current (In): 6-40A
Rated working voltage (Ue): AC 230V
Rated operating frequency: 50/60Hz
Rated insulation voltage (Ui): 500V
Rated residual operating current : 10/30/100/300mA
Life: 4000 Times
Residual current type: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic /Electromagnetic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230 Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life : 4000 Times Type of residual current: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity( Icn): 6kA Release Type of Leakage Protection: Electronic Rated working current In: 6-40A Rated working voltage (Ue): AC 230V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life :4000 Times Residual current type: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic /Electromagnetic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Type of residual current : A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N/3P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Type of residual current: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 4.5kA Release Type of Leakage Protection: Electronic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Residual current type: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 10kA Release Type of Leakage Protection: Electronic /Electromagnetic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Residual current type: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity Icn: 4.5kA Release Type of Leakage Protection: Electronic Rated working current (In): 6-32A Rated working voltage (Ue): AC 230V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Residual current type: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N/3P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic Rated working current (In): 6-63A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Type of residual current : A/AC