Earth leakage circuit breaker
The elcb is micro controller based with shock guard which continuously displays all the parameters and with inbuilt seven segment display and indicates the reason for tripping.
Dimensions 17.5x13.5x8 cm
Weight 1.5kg approx
An Earth Leakage circuit breaker (ELCB) (now referred to as residual current circuit breaker-RCCB) is a safety device used in electrical installation with high earth impedance to prevent shock. High Quality circuit breaker (ELCB’S) Manufacturer and Exporters provides Automatic models as well as manual models ELCB’s.
- USED ELCB - Made in Korea brands (Mixed : LS, Hyundai, Daco....) -15 ~ 30A - 8 ~10pcs/kg (FOB 4.9usd /kg)
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic /Electromagnetic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230 Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life : 4000 Times Type of residual current: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity( Icn): 6kA Release Type of Leakage Protection: Electronic Rated working current In: 6-40A Rated working voltage (Ue): AC 230V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life :4000 Times Residual current type: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic /Electromagnetic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Type of residual current : A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N/3P+N Rated short circuit breaking capacity (Icn): 6kA Leakage protection trip type: Electronic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230/400V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Type of residual current: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 4.5kA Release Type of Leakage Protection: Electronic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Residual current type: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 10kA Release Type of Leakage Protection: Electronic /Electromagnetic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Residual current type: A/AC
Standard: IEC/EN61009-1 GB/T16917.1 Instantaneous trip type: B/C/D The number of poles: 1P+N Rated short circuit breaking capacity (Icn): 6kA Release Type of Leakage Protection: Electronic Rated working current (In): 6-40A Rated working voltage (Ue): AC 230V Rated operating frequency: 50/60Hz Rated insulation voltage (Ui): 500V Rated residual operating current : 10/30/100/300mA Life: 4000 Times Residual current type: A/AC