NO-A1 Nitric Oxide Sensor (NO Sensor) Description Alphasense Nitric Oxide gas sensors operate using proven fuel cell technology. NO-A1 Nitric Oxide Sensor size: 20mm diameter, the industry standard size for portable gas detectors The NO range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 200 parts per billion (ppb) whilst giving linear outputs to as high as 250ppm. The sensors are suitable for inclusion in fixed installation sensing heads, portable safety instruments, urban air monitoring and stack gas analysers. Alphasense NO sensors provide a significant improvement in stability of response to transient relative humidity changes. The NO sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification. NO-A1 Nitric Oxide Sensor NO sensor Specifications * Range: 250 ppm NO limit of performance warranty * Sensitivity: 320 to 480 nA/ppm in 50ppm NO * Response time t90: < 45s from zero to 50ppm NO * Resolution: < 0.2 RMS noise (ppm equivalent) * Temperature range: -30 to 50'C * Pressure range: 80 to 120 kPa * Humidity range: 15 to 90 % rh continuous * Weight: < 6 g
NO-B1 Nitric Oxide Sensor (NO Sensor) Description Alphasense Nitric Oxide gas sensors operate using proven fuel cell technology. NO-B1 Nitric Oxide Sensor size: 32mm diameter package, the best choice for fixed site applications The NO range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 200 parts per billion (ppb) whilst giving linear outputs to as high as 250ppm. The sensors are suitable for inclusion in fixed installation sensing heads, portable safety instruments, urban air monitoring and stack gas analysers. Alphasense NO sensors provide a significant improvement in stability of response to transient relative humidity changes. The NO sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification. NO-B1 Nitric Oxide Sensor (NO Sensor) Specification * Range: 250ppm NO limit of performance warranty * Sensitivity: 400 to 620nA/ppm in 50ppm NO * Resolution: < 0.15 RMS noise (ppm equivalent) * Response time t90: < 30s from zero to 50ppm NO * Temperature range: -30 to 50 deg C * Pressure range: 80 to 120 kPa * Humidity range: 15 to 90 % rh continuous * Weight: < 13g
FECS41-250 for the Detection of Nitric Oxide Figaro's Nitric Oxide Sensor FECS41-250 is a unique electrochemical-type nitric oxide sensor. Its most notable feature is its unique leak-proof structure, making it ideal for NO monitors and detectors in various fields. FECS41-250 Nitric Oxide (NO) Sensor Features: * High sensitivity/selectivity to NO * Quick response to NO * Linear output * Long life * Stable baseline * Unique leak-proof structure FECS41-250 Nitric Oxide (NO) Sensor Applications: * Portable and fixed installation NO monitors * NO detectors * Ventilation control for indoor parking garages FECS41-250 Nitric Oxide (NO) Sensor Specifications * Detection Gas: Nitric Oxide * Detection Range: 0 ~ 300 ppm * Maximum Overload: 1000 ppm * Output Signal: 400 ± 80 nA/ppm * Repeatability: ±2% * Resolution: 0.5 ppm
NX1 CiTiceL Nitric Oxide Sensor (NO Sensor) Key Features & Benefits: * Designed for Automotive Applications * Fast Response
NO-AE Nitric Oxide Sensor (NO Sensor) Description Alphasense Nitric Oxide gas sensors operate using proven fuel cell technology. NO-AENitric Oxide Sensor size: 20mm diameter, the industry standard size for portable gas detectors The NO range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 200 parts per billion (ppb) whilst giving linear outputs to as high as 250ppm. The sensors are suitable for inclusion in fixed installation sensing heads, portable safety instruments, urban air monitoring and stack gas analysers. Alphasense NO sensors provide a significant improvement in stability of response to transient relative humidity changes. The NO sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification. NO-AE Nitric Oxide Sensor (NO Sensor) Specification * Range: 5,000ppm NO limit of performance warranty * Sensitivity: 40 to 80nA/ppm in 250ppm NO * Resolution: < 1 RMS noise (ppm equivalent) * Response time t90: < 75s from zero to 250ppm NO * Temperature range: -30 to +50'C * Pressure range: 80 to 120 kPa * Humidity range: 15 to 90 % rh continuous * Weight: < 6 g Matched Transmitter board for NO-AE NO Sensor 4-20mA Digital Transmitter Board * Factory calibration, custom-set for immediate use * Digital zero, sensitivity and temperature compensation * Digital and 4-20mA output * Biased or unbiased operation * Calibration and range change
ETO-A1 Ethylene Oxide Sensor ETO Sensor Description Alphasense is expanding its line of Electrochemical Toxic Gas Sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs. Ethylene Oxide (C2H4O) The ETO is a general purpose sensor, primarily developed for monitoring Ethylene Oxide but also capable of measuring other volatile organic compounds (VOCs). Our toxic evaluation board allows easy adjustment of the bias voltage to optimise this sensor for the required application. See application note AAN113. Available in A and B series ETO-A1 Ethylene Oxide Sensor ETO Sensor Specifications * Range: 100 ppm EtO limit of performance warranty * Sensitivity: 2000 to 3200 nA/ppm in 20ppm EtO * Response time t90: < 150s from zero to 20ppm EtO * Resolution: < 0.1 RMS noise (ppm equivalent) * Temperature range: -30 to 50'C * Pressure range: 80 to 120kPa * Humidity range: 15 to 90% rh continuous * Weight: < 6 g
ETO-A1 Ethylene Oxide Sensor ETO Sensor Description Alphasense is expanding its line of Electrochemical Toxic Gas Sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs. Ethylene Oxide (C2H4O) The ETO is a general purpose sensor, primarily developed for monitoring Ethylene Oxide but also capable of measuring other volatile organic compounds (VOCs). Our toxic evaluation board allows easy adjustment of the bias voltage to optimise this sensor for the required application. See application note AAN113. Available in A and B series ETO-A1 Ethylene Oxide Sensor ETO Sensor Specifications * Range: 100 ppm EtO limit of performance warranty * Sensitivity: 2000 to 3200 nA/ppm in 20ppm EtO * Response time t90: < 150s from zero to 20ppm EtO * Resolution: < 0.1 RMS noise (ppm equivalent) * Temperature range: -30 to 50 deg C * Pressure range: 80 to 120kPa * Humidity range: 15 to 90% rh continuous * Weight: < 6 g
With a Freestyle Libre Sensor you can continuously measure your blood sugar for 14 days. Attaching the sensor using the sensor applicator is well described in the instructions for use. When attaching the sensor, a small, 5mm long, flexible cannula is placed under the skin (usually painless). The sensor is worn on the back of the upper arm and continuously measures your glucose levels. It is waterproof and can be worn while bathing, showering or swimming. If you set up additional optional alarms, you will be warned in good time about hypoglycemia, for example, and can therefore feel even safer - day and night.
Gillette Fusion5 men's razor blade refills each have 5 precision blades spaced closer together (vs. Mach3) for less feel of irritation and incredible comfort. Each blade refill also has a Precision Trimmer on the back, great for edging tough areas such as under the nose and sideburns. One razor blade refill equals up to one month of shaves. These Fusion5 blade refills can be used with any Fusion5 razor handle. Features include: 5 precision blades, helping reduce pressure per blade for a comfortable shave (vs. Mach3) Precision Trimmer on back great for edging tough areas (nose and sideburns) 1 razor blade refill equals up to one month of shaves Fits with any Fusion5 blade refills
CL2-A1 Chlorine Sensor (CL2 Sensor) Description Alphasense Chlorine gas sensors operate using proven fuel cell technology. CL2-A1 Chlorine Sensor size: 20mm diameter, the industry standard size for portable gas detectors The Cl2 range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 20ppb and an operating range from +0 to 20ppm. The sensors are suitable for inclusion in fixed installation sensing heads and portable safety instruments. These sensors have improved transient response to humidity changes compared to competitors' equivalent sensors. The Cl2 sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification. CL2-A1 Chlorine Sensor (CL2 Sensor) Specifications * Range: 20 ppm limit of performance warranty * Sensitivity: -350 to -750 nA/ppm in 10ppm Cl2 * Response time t90: < 60s from zero to 10ppm Cl2 * Resolution: < 0.02 RMS noise * Operating life: > 24 months * Temperature range: -20 to 50'C * Pressure range: 80 to 120 kPa * Humidity range: 15 to 90 %rh continuous * Weight: < 6 g
NO2-A1 Nitrogen Dioxide Sensor (NO2 Sensor) Description Alphasense Nitrogen Dioxide gas sensors operate using proven fuel cell technology. NO2-A1 Nitrogen Dioxide Sensor size: 20mm diameter, the industry standard size for portable gas detectors The NO2 range provides OEMs with reliable sensors for use in a number of high volume applications. Strong signal levels combined with low zero current allows resolution to 50 parts per billion (ppb) and an operating range to 20ppm. The sensors are suitable for use in fixed installation sensing heads, portable safety instruments, urban air monitoring and stack gas analysers. The NO2 sensors offer our electrolyte leak-free guarantee and reliable long-term detection performance. The leakproof housing is moulded with a colour coded top for ease of identification. NO2-A1 Nitrogen Dioxide Sensor (NO2 Sensor) Specifications * Range: 20 ppm NO2 limit of performance warranty * Sensitivity: -250 to -650 nA/ppm in 10ppm NO2 * Response time t90: < 50 (s) from zero to 10ppm NO2 * Resolution: < 0.02 RMS noise (ppm equivalent) * Temperature range : -20 to 50 deg C * Pressure range: 80 to 120 kPa * Humidity range: 15 to 90 % rh continuous * Weight: < 6 g
NH3-A1 Ammonia Sensor NH3 Sensor Description Alphasense is expanding its line of electrochemical toxic gas sensors to address industry-specific requirements, including emissions monitoring, process safety, environmental monitoring and VOCs. Ammonia (NH3) Our first family of Ammonia sensors. This sensor is designed for higher concentrations of Ammonia. Sensors for lower level detection are in development. NH3-A1 Ammonia Sensor NH3 Sensor Specifications * Range: 200 ppm NH3 limit of performance warranty * Sensitivity: 17 to 27 nA/ppm in 50ppm NH3 * Response time t90:
H2S-A1 Hydrogen Sulfide Sensor H2S Sensor Description Alphasense Hydrogen Sulfide gas sensors operate using well-known fuel cell technology. H2S-A1 Hydrogen Sulfide Sensor size: 20mm diameter, the industry standard size for portable gas detectors With very high sensitivity and low zero, accurate and stable readings are possible when measuring current concentration ranges from ppb to 1% H2S. H2S-A1 Hydrogen Sulfide Sensor H2S Sensor Specification * Range: 100ppm H2S limit of performance warranty * Sensitivity: 550 to 875 nA/ppm in 20ppm H2S * Response time t90: < 35s from zero to 20ppm H2S * Resolution: < 0.05 RMS noise (ppm equivalent) * Temperature range: -30 to 50'C * Pressure range: 80 to 120 kPa * Humidity range: 15 to 90 % rh continuous * Weight: < 6 g Matched Transmitter board for H2S-A1 H2S Sensor 4-20 mA Digital Transmitter Board * Factory calibration, custom-set for immediate use * Digital zero, sensitivity and temperature compensation * Digital and 4-20mA output * Biased or unbiased operation * Calibration and range change
PCFS-IR2125A level sensor contact type, it is used for tube. The principle is infrared, output signal is analog. When there is no water, the sensor outputs low voltage value; When there is water, the sensor outputs a high voltage signal. The size can be customized. The photoelectric liquid level switch has high precision, low price, high reliability and wide application environment, it is less affected by strong acid, alkali and viscosity. Photoelectric level sensors can be used for higher liquid level accuracy requirements.
Application: Siren and alarms is widely used in fire fighting, car, office, residential building and security equipment etc Specifications: Dc resistance: 19 ohm +/- 10% Impedance: 100 ohm +/- 25% at 1khz Frequency range: 2000hz +/- 20% S.P.L: >= 90db at 10cm 2000hz 9vp-p square wave >= 95db at 30cm 1000hz 12vp-p square wave Export standard carton
Agecho ultrasonic sensors salient features: Agecho ultrasonic sensors are available with output options such as analog current 4-20ma analogue voltage 0-5v on/off signal trigger output for multi-sensor application pulse width serial ttl serial rs 232c. Agecho is very useful non-contact type of sensing or presence or counting of object. On/off type signal is also available. Agecho sensing range: 200mm to 1000mm … up to … 6000mm. (19.7feet) (0-200mm is dead band). Agecho accuracy is 1% of the full scale. Agecho operating voltage 12v dc with reverse polarity protection.(24v dc optional) Agecho is self-calibrated. Microcontroller is present in each sensor. This provides direct distance/depth reading with better calibration and communication with the controller module. Agecho is very easy to install rugged design for use in dusty and humid conditions suitable for outdoor as well as indoor use. Agecho very useful for non-contact distance/level measurement. The distance of the target is measured not just its presence but gives directly 4-20ma serial or pulse width data proportional to the distance of the target. Agecho operating temperature 0 to 65 degree celsius. Agecho temperature compensated measurement for better accuracy (optional). Agecho unaffected by ambient light object color or any other optical characteristic. Works with hard materials like metal sheet plywood or soft materials like cloth and paper rubber etc.
Professional; improving; cooperation; win-win: these are our philosophy. We believe quality is the life of company and honesty is the basic rule of market. We will try our best to offer satisfying service. And welcome your cooperation. All size you want